{"product_id":"hydrowhiz-submersible-level-controller-3ph-3-pump-soft-starter-fpc-63343-s4-0-s90","title":"HydroWHIZ Submersible Level Controller (3PH 3 Pump Soft Starter) - FPC-63343-(S4.0-S22)","description":"\u003cp bis_size='{\"x\":12,\"y\":9,\"w\":560,\"h\":156,\"abs_x\":618,\"abs_y\":270}'\u003eMATelec Australia's HydroWHIZ Submersible Level Controller is a premium multi-pump controller designed for advanced control of submersible pumping systems. Featuring a colour touchscreen HMI, HydroWHIZ PCB control module and flexible level, pressure and temperature control modes, it provides comprehensive pump control, monitoring and protection. This three-phase, three-pump version supports advanced functions including pump staging and destaging, duty sharing and alternation, staggered pump start and stop, pump limiting, data logging, trend graphs and diagnostic functions. The soft starter version is available with soft starter ratings from 4.0 kW to 90 kW.\u003c\/p\u003e\n\u003ch3 bis_size='{\"x\":12,\"y\":182,\"w\":560,\"h\":22,\"abs_x\":618,\"abs_y\":443}'\u003eProduct Details\u003c\/h3\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":215,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":476}'\u003eEnclosure\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":249,\"w\":560,\"h\":78,\"abs_x\":618,\"abs_y\":510}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":249,\"w\":520,\"h\":39,\"abs_x\":658,\"abs_y\":510}'\u003eIP56 rated, powder-coated mild steel enclosure with inner door and removable gland plate\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":288,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":549}'\u003eEnclosure size: 400x400x250mm+\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":308,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":569}'\u003eEnclosure size will increase for soft starter ratings and optional additions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":341,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":602}'\u003eProtection\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":375,\"w\":560,\"h\":97,\"abs_x\":618,\"abs_y\":636}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":375,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":636}'\u003ePad-lockable mains power isolator switch\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":394,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":655}'\u003eCircuit breaker protected low voltage control and input circuitry\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":414,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":675}'\u003eIndividual pump isolation\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":434,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":695}'\u003eContactor protection of pump motors\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":453,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":714}'\u003eDin rail-mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":487,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":748}'\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":520,\"w\":560,\"h\":176,\"abs_x\":618,\"abs_y\":781}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":520,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":781}'\u003eHydroWHIZ colour touch screen HMI\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":540,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":801}'\u003eHydroWHIZ PCB control module\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":560,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":821}'\u003eVisual strobe and mutable audible buzzer alarms\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":579,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":840}'\u003eMain screen with system status and auto\/off\/manual modes\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":599,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":860}'\u003ePump screens with status, logged data and auto\/off\/manual control\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":618,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":879}'\u003eAlarm screens with mute\/reset and date and time-stamped historical faults\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":638,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":899}'\u003eLogged data including system event and fault counts, pump starts and run hours\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":658,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":919}'\u003eAnalogue feedback value trend graph\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":677,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":938}'\u003eSystem diagnostics and factory reset\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":711,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":972}'\u003eInputs\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":744,\"w\":560,\"h\":137,\"abs_x\":618,\"abs_y\":1005}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":744,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1005}'\u003eThree phase (400Vac) power supply\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":764,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1025}'\u003eAnalogue 4-20mA input for level, pressure or temperature transducer\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":784,\"w\":520,\"h\":39,\"abs_x\":658,\"abs_y\":1045}'\u003eUp to 8x digital 24Vdc inputs for low, stop, start, standby start and high float switches, pressure switches or thermostats\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":823,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1084}'\u003eSystem enable\/disable input\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":842,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1103}'\u003eLow flow switch input\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":862,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1123}'\u003eThermal switch inputs per pump\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":896,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":1157}'\u003eOutputs\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":929,\"w\":560,\"h\":97,\"abs_x\":618,\"abs_y\":1190}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":929,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1190}'\u003e3 pump outputs\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":949,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1210}'\u003eBMS volt-free output for common fault\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":968,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1229}'\u003eAnalogue 0-10V output mirroring the analogue input\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":988,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1249}'\u003eOutput for solenoid valve available on request\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1008,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1269}'\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":1041,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":1302}'\u003eSoft Starter\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":1075,\"w\":560,\"h\":39,\"abs_x\":618,\"abs_y\":1336}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1075,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1336}'\u003eSoft starter control\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1094,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1355}'\u003eSoft starter rating: 4.0 kW to 90 kW\u003c\/li\u003e\n\u003cli\u003eSoft starter rating above 22 kw to 90kw prices will be available upon request.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":1128,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":1389}'\u003eFunction Features\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":1161,\"w\":560,\"h\":215,\"abs_x\":618,\"abs_y\":1422}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1161,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1422}'\u003eControl of up to 6 pumps in duty, duty assist and standby configurations\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1181,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1442}'\u003ePump limiting for maximum flow or power requirements\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1201,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1462}'\u003eAdjustable duty sharing and alternation\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1220,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1481}'\u003ePump staging and destaging\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1240,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1501}'\u003eStaggered pump start and stop\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1259,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1520}'\u003eManual system and pump control with 10-minute timeout\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1279,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1540}'\u003eLevel, pressure or temperature control\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1299,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1560}'\u003eTank emptying or filling control\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1318,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1579}'\u003e4-20mA hydrostatic level transducer and float switch level control\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1338,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1599}'\u003eTank top-up valve control\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1357,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1618}'\u003eMaintain minimum level function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":1391,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":1652}'\u003eFault Protection\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":1425,\"w\":560,\"h\":176,\"abs_x\":618,\"abs_y\":1686}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1425,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1686}'\u003eHigh and low level, pressure or temperature protection\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1444,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1705}'\u003eAuxiliary tank level protection\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1464,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1725}'\u003ePump anti-seize protection\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1483,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1744}'\u003eMaximum run protection\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1503,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1764}'\u003ePump cycle protection\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1523,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1784}'\u003eNo flow protection\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1542,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1803}'\u003eFeedback signal fault protection\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1562,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1823}'\u003ePump overload protection\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1581,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1842}'\u003ePump thermal switch protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 bis_size='{\"x\":12,\"y\":1615,\"w\":560,\"h\":22,\"abs_x\":618,\"abs_y\":1876}'\u003eCommon Applications\u003c\/h3\u003e\n\u003cul bis_size='{\"x\":12,\"y\":1652,\"w\":560,\"h\":137,\"abs_x\":618,\"abs_y\":1913}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1652,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1913}'\u003eWater Transfer\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1671,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1932}'\u003eTank Fill\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1691,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1952}'\u003eSewage Pump Out\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1711,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1972}'\u003eStormwater Pump Out\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1730,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1991}'\u003ePressure Boosting\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1750,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":2011}'\u003eHot Water Recirculation\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1769,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":2030}'\u003eChiller Supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 bis_size='{\"x\":12,\"y\":1803,\"w\":560,\"h\":22,\"abs_x\":618,\"abs_y\":2064}'\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"pdf-table\" bis_size='{\"x\":12,\"y\":1836,\"w\":560,\"h\":29,\"abs_x\":618,\"abs_y\":2097}'\u003e\n\u003ctbody bis_size='{\"x\":15,\"y\":1839,\"w\":554,\"h\":23,\"abs_x\":621,\"abs_y\":2100}'\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":1839,\"w\":554,\"h\":23,\"abs_x\":621,\"abs_y\":2100}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":1839,\"w\":358,\"h\":23,\"abs_x\":621,\"abs_y\":2100}'\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":375,\"y\":1839,\"w\":193,\"h\":23,\"abs_x\":981,\"abs_y\":2100}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/e54d9eba0e4ab3257a8d93c1c52aaa5a00c4f088.pdf\" bis_size='{\"x\":377,\"y\":1841,\"w\":63,\"h\":19,\"abs_x\":983,\"abs_y\":2102}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"-S4.0 \/ 4.0 kW","offer_id":45597630791789,"sku":"FPC-63343-S90","price":9119.44,"currency_code":"AUD","in_stock":true},{"title":"-S5.5 \/ 5.5 kW","offer_id":45597630824557,"sku":"FPC-63343-S5.5","price":9610.48,"currency_code":"AUD","in_stock":true},{"title":"-S7.5 \/ 7.5 kW","offer_id":45597630857325,"sku":"FPC-63343-S7.5","price":10124.4,"currency_code":"AUD","in_stock":true},{"title":"-S11 \/ 11 kW","offer_id":45597630890093,"sku":"FPC-63343-S11","price":11153.12,"currency_code":"AUD","in_stock":true},{"title":"-S15 \/ 15 kW","offer_id":45597630922861,"sku":"FPC-63343-S15","price":11919.6,"currency_code":"AUD","in_stock":true},{"title":"-S22 \/ 22 kW","offer_id":45597630955629,"sku":"FPC-63343-S22","price":15143.04,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPC-63343-product.webp?v=1785397859","url":"https:\/\/pumptastic.com.au\/products\/hydrowhiz-submersible-level-controller-3ph-3-pump-soft-starter-fpc-63343-s4-0-s90","provider":"Pumptastic","version":"1.0","type":"link"}