{"product_id":"hydrostart-pro-submersible-pump-controller-3ph-2-pump-fpp-82243","title":"HydroSTART PRO Submersible Pump Controller (3PH 2 Pump) - FPP-82243","description":"\u003cp bis_size='{\"x\":12,\"y\":9,\"w\":565,\"h\":78,\"abs_x\":618,\"abs_y\":270}'\u003eMATelec Australia’s HydroSTART PRO Controller is the flagship dual pump controller in the Australian Market. Designed for the professional, this controller features the highest quality enclosure, premium Schneider switchgear, intuitive capacitive touch keypad and Matelec Australia’s Market Leading HydroSTART Pro Control module.\u003c\/p\u003e\n\u003cp bis_size='{\"x\":12,\"y\":103,\"w\":565,\"h\":78,\"abs_x\":618,\"abs_y\":364}'\u003eThe unit comes complete with pump current sensing and a wide range of electronic overload protection for both single and three phase pumps. A full suite of control inputs and functionality has been incorporated into the design to enhance the controller’s flexibility and cover an even wider range of pumping applications.\u003c\/p\u003e\n\u003ch3 bis_size='{\"x\":12,\"y\":198,\"w\":565,\"h\":22,\"abs_x\":618,\"abs_y\":459}'\u003eProduct Details\u003c\/h3\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":231,\"w\":565,\"h\":19,\"abs_x\":618,\"abs_y\":492}'\u003eEnclosure Options\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":265,\"w\":565,\"h\":58,\"abs_x\":618,\"abs_y\":526}'\u003e\n\u003cli\u003eGrey powder coated galvanised mild steel IP66 with inner door\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":285,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":546}'\u003eEnclosure size: 400x400x200mm\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":304,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":565}'\u003eEnclosure size will increase for optional additions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":338,\"w\":565,\"h\":19,\"abs_x\":618,\"abs_y\":599}'\u003eProtection\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":371,\"w\":565,\"h\":117,\"abs_x\":618,\"abs_y\":632}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":371,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":632}'\u003eInner door mounted main isolator with door interlock\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":391,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":652}'\u003ePremium Schneider Circuit Breakers for individual pump protection\/isolation\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":410,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":671}'\u003eLow voltage control and input circuitry\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":430,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":691}'\u003ePremium Schneider Contactors for pump switching (three phase panels)\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":450,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":711}'\u003eElectronic short and overload protection of alarms\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":469,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":730}'\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":503,\"w\":565,\"h\":19,\"abs_x\":618,\"abs_y\":764}'\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":536,\"w\":565,\"h\":117,\"abs_x\":618,\"abs_y\":797}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":536,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":797}'\u003eHydroSTART dual pump capacitive touch keypad interface\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":556,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":817}'\u003eIndicator lights for system, pump and input status, level alarm\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":576,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":837}'\u003eButtons for alarm mute\/reset and pump mode selection\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":595,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":856}'\u003eHydroSTART PCB control module with dip-switches for adjusting configuration\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":615,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":876}'\u003eVisual (strobe) and audible (buzzer) alarms\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":634,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":895}'\u003ePump current sensing providing adjustable overload \u0026amp; other protections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":668,\"w\":565,\"h\":19,\"abs_x\":618,\"abs_y\":929}'\u003eInputs\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":702,\"w\":565,\"h\":97,\"abs_x\":618,\"abs_y\":963}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":702,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":963}'\u003ethree phase (400Vac) power supply\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":721,\"w\":525,\"h\":39,\"abs_x\":658,\"abs_y\":982}'\u003e6x digital inputs for float or pressure switches, optional prime loss flow switch and system enable\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":760,\"w\":525,\"h\":39,\"abs_x\":658,\"abs_y\":1021}'\u003eStandard terminal setup: Low level, duty stop, duty start, standby start, high level and system enable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":814,\"w\":565,\"h\":19,\"abs_x\":618,\"abs_y\":1075}'\u003eOutputs\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":847,\"w\":565,\"h\":58,\"abs_x\":618,\"abs_y\":1108}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":847,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":1108}'\u003e2x pump supply outputs\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":867,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":1128}'\u003eBMS volt free output for common fault\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":886,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":1147}'\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":920,\"w\":565,\"h\":19,\"abs_x\":618,\"abs_y\":1181}'\u003eFunctions\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":954,\"w\":565,\"h\":195,\"abs_x\":618,\"abs_y\":1215}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":954,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":1215}'\u003eLevel control mode – Level empty operation controlled by up to 5 float switches\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":973,\"w\":525,\"h\":39,\"abs_x\":658,\"abs_y\":1234}'\u003ePressure control mode – Pressure boost operation controlled by up to 3 pressure switches\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1012,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":1273}'\u003eDuty sharing and alternation – Alternates on pump start and after set run times\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1032,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":1293}'\u003eStaggered pump start – Prevents excessive current draw and reduces water surge\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1052,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":1313}'\u003eManual pump control – Manual mode with optional timeout\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1071,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":1332}'\u003eSystem enable input – Enables\/disables system in auto mode\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1091,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":1352}'\u003eStatic duty mode – No duty alternation\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1110,\"w\":525,\"h\":39,\"abs_x\":658,\"abs_y\":1371}'\u003eSmart chirp mode alarms – Audible alarm silences after 5 minutes, chirps every 5 minutes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":1163,\"w\":565,\"h\":19,\"abs_x\":618,\"abs_y\":1424}'\u003eFault Protection\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":1197,\"w\":565,\"h\":137,\"abs_x\":618,\"abs_y\":1458}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1197,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":1458}'\u003eHigh level alarm – Delayed alarm with auto\/manual reset depending on mode\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1217,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":1478}'\u003eLow level protection – Shuts down pumps, manual reset only\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1236,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":1497}'\u003eLow pressure protection – Shuts down pumps if input closed for 60 seconds\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1256,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":1517}'\u003ePrime loss protection – Shuts down pumps if no flow for 30 seconds\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1275,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":1536}'\u003ePump anti-seize protection – Runs pumps periodically during low use\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1295,\"w\":525,\"h\":39,\"abs_x\":658,\"abs_y\":1556}'\u003ePump current sensing – Adjustable overload, undercurrent and zero current protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 bis_size='{\"x\":12,\"y\":1348,\"w\":565,\"h\":22,\"abs_x\":618,\"abs_y\":1609}'\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\" bis_size='{\"x\":12,\"y\":1382,\"w\":565,\"h\":55,\"abs_x\":618,\"abs_y\":1643}'\u003e\n\u003ctbody bis_size='{\"x\":15,\"y\":1385,\"w\":559,\"h\":49,\"abs_x\":621,\"abs_y\":1646}'\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":1385,\"w\":559,\"h\":23,\"abs_x\":621,\"abs_y\":1646}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":1385,\"w\":438,\"h\":23,\"abs_x\":621,\"abs_y\":1646}'\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":455,\"y\":1385,\"w\":119,\"h\":23,\"abs_x\":1061,\"abs_y\":1646}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/49bb51d56250b36b65102dad6bfc116f753bea7e.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":457,\"y\":1387,\"w\":63,\"h\":19,\"abs_x\":1063,\"abs_y\":1648}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":1410,\"w\":559,\"h\":23,\"abs_x\":621,\"abs_y\":1671}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":1410,\"w\":438,\"h\":23,\"abs_x\":621,\"abs_y\":1671}'\u003eAutomation and Control Product Guide\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":455,\"y\":1410,\"w\":119,\"h\":23,\"abs_x\":1061,\"abs_y\":1671}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/0fde2ce949a2d88c6cf6a1fee529c31b7451011f.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":457,\"y\":1412,\"w\":63,\"h\":19,\"abs_x\":1063,\"abs_y\":1673}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"Default Title","offer_id":45617222746221,"sku":"FPP-82243","price":4431.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPP-82243-PC-premium-polycarbonate-product.webp?v=1786603805","url":"https:\/\/pumptastic.com.au\/products\/hydrostart-pro-submersible-pump-controller-3ph-2-pump-fpp-82243","provider":"Pumptastic","version":"1.0","type":"link"}