{"product_id":"hydrostart-1ph-2-pump-0-1-16a-c-w-id-sms-bms-fpc-82241-sms-bms","title":"HydroSTART 1PH 2 Pump 0.1-16A c\/w ID, SMS \u0026 BMS - FPC-82241-SMS\/BMS","description":"\u003cp bis_size='{\"x\":12,\"y\":9,\"w\":565,\"h\":97,\"abs_x\":618,\"abs_y\":270}'\u003eThe MATelec HydroSTART FPC-82241-SMS\/BMS is a single-phase dual pump controller designed for control and protection of two pumps. It features a capacitive touch keypad, pump current sensing with adjustable electronic overload protection, an IP56 enclosure with inner door for outdoor mounting, an SMS module for alarm and status messaging, and a BMS module providing additional volt-free outputs.\u003c\/p\u003e\n\u003ch3 bis_size='{\"x\":12,\"y\":123,\"w\":565,\"h\":22,\"abs_x\":618,\"abs_y\":384}'\u003eProduct Details\u003c\/h3\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":157,\"w\":565,\"h\":19,\"abs_x\":618,\"abs_y\":418}'\u003eEnclosure\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":190,\"w\":565,\"h\":58,\"abs_x\":618,\"abs_y\":451}'\u003e\n\u003cli\u003eEnclosure size: 400x400x200mm\u003c\/li\u003e\n\u003cli\u003ePowder coated mild steel enclosure with removable gland plate\u003c\/li\u003e\n\u003cli\u003eIP56 rated with inner door for outdoor mounting\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eEnclosure size will increase for optional additions\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":263,\"w\":565,\"h\":19,\"abs_x\":618,\"abs_y\":524}'\u003eProtection\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":297,\"w\":565,\"h\":97,\"abs_x\":618,\"abs_y\":558}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":297,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":558}'\u003ePadlockable mains power isolator switch\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":316,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":577}'\u003eLow voltage control and input circuitry\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":336,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":597}'\u003eIndividual pump circuit breaker protection and isolation\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":355,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":616}'\u003eAdjustable electronic pump overload protection\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":375,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":636}'\u003eUndercurrent and zero-current protection through pump current sensing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":408,\"w\":565,\"h\":19,\"abs_x\":618,\"abs_y\":669}'\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":442,\"w\":565,\"h\":215,\"abs_x\":618,\"abs_y\":703}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":442,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":703}'\u003eHydroSTART capacitive touch keypad interface\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":462,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":723}'\u003eIndicator lights for system, pump and input status\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":481,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":742}'\u003eAlarm mute\/reset and pump mode selection\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":501,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":762}'\u003eHydroSTART control module with configurable DIP switches\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":520,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":781}'\u003eVisual strobe and audible buzzer alarms\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":540,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":801}'\u003eDuty sharing and pump alternation\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":560,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":821}'\u003eStaggered pump start\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":579,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":840}'\u003eManual pump control\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":599,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":860}'\u003eSystem enable input\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":618,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":879}'\u003eStatic duty mode\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":638,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":899}'\u003eSmart chirp alarm mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":672,\"w\":565,\"h\":19,\"abs_x\":618,\"abs_y\":933}'\u003eInputs\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":705,\"w\":565,\"h\":78,\"abs_x\":618,\"abs_y\":966}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":705,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":966}'\u003eSingle-phase 230Vac power supply\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":725,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":986}'\u003e6 digital inputs for float or pressure switches\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":744,\"w\":525,\"h\":39,\"abs_x\":658,\"abs_y\":1005}'\u003eStandard inputs for low level, duty stop, duty start, standby start, high level and system enable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":798,\"w\":565,\"h\":19,\"abs_x\":618,\"abs_y\":1059}'\u003eOutputs\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":831,\"w\":565,\"h\":78,\"abs_x\":618,\"abs_y\":1092}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":831,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":1092}'\u003e2 pump supply outputs\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":851,\"w\":525,\"h\":39,\"abs_x\":658,\"abs_y\":1112}'\u003eBMS module providing volt-free outputs for power on, low level, high level, individual pump run and fault, and common fault\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":890,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":1151}'\u003eModbus RTU Serial RS485 connection for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":924,\"w\":565,\"h\":19,\"abs_x\":618,\"abs_y\":1185}'\u003eSMS\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":957,\"w\":565,\"h\":19,\"abs_x\":618,\"abs_y\":1218}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":957,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":1218}'\u003eME-Link module for SMS alarm and status messaging\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 bis_size='{\"x\":12,\"y\":991,\"w\":565,\"h\":22,\"abs_x\":618,\"abs_y\":1252}'\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\" bis_size='{\"x\":12,\"y\":1024,\"w\":565,\"h\":29,\"abs_x\":618,\"abs_y\":1285}'\u003e\n\u003ctbody bis_size='{\"x\":15,\"y\":1027,\"w\":559,\"h\":23,\"abs_x\":621,\"abs_y\":1288}'\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":1027,\"w\":559,\"h\":23,\"abs_x\":621,\"abs_y\":1288}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":1027,\"w\":361,\"h\":23,\"abs_x\":621,\"abs_y\":1288}'\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":378,\"y\":1027,\"w\":195,\"h\":23,\"abs_x\":984,\"abs_y\":1288}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/08f5a11902b64509503920491cac62bb60c5a92e.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":380,\"y\":1029,\"w\":63,\"h\":19,\"abs_x\":986,\"abs_y\":1290}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"Default Title","offer_id":45659317534829,"sku":"FPC-82241-SMS\/BMS","price":4341.92,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPC-82143-CON-IOT-product.webp?v=1786691540","url":"https:\/\/pumptastic.com.au\/products\/hydrostart-1ph-2-pump-0-1-16a-c-w-id-sms-bms-fpc-82241-sms-bms","provider":"Pumptastic","version":"1.0","type":"link"}