{"product_id":"grundfos-crn-3-21-a-fgj-a-v-hqqv-vertical-multistage-centrifugal-pump-96480979","title":"Grundfos CRN 3-21 A-FGJ-A-V-HQQV Vertical Multistage Centrifugal Pump – 96480979 (3 x 220-240D\/380-415YV)","description":"\u003cp\u003eThe Grundfos CRN 3-21 A-FGJ-A-V-HQQV is a vertical, non-self-priming, multistage in-line centrifugal pump engineered for commercial, industrial, irrigation, and water treatment applications. Featuring high-grade stainless steel wetted parts and a single HQQV shaft seal, it ensures efficient, reliable operation for water transfer, pressure boosting, and process liquids handling.\u003c\/p\u003e\n\n\u003ch3\u003eSuitable Applications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial heating\u003c\/li\u003e\n  \u003cli\u003eCommercial air conditioning\u003c\/li\u003e\n  \u003cli\u003eCommercial water pressure boosting\u003c\/li\u003e\n  \u003cli\u003eDistrict heating\u003c\/li\u003e\n  \u003cli\u003eDistrict cooling\u003c\/li\u003e\n  \u003cli\u003eMachining\u003c\/li\u003e\n  \u003cli\u003eWash and clean\u003c\/li\u003e\n  \u003cli\u003eProcess liquids transfer\u003c\/li\u003e\n  \u003cli\u003eIndustrial heating\u003c\/li\u003e\n  \u003cli\u003eCooling\u003c\/li\u003e\n  \u003cli\u003eIndustrial water supply\u003c\/li\u003e\n  \u003cli\u003eIndustrial wastewater\u003c\/li\u003e\n  \u003cli\u003eIndustrial process water treatment\u003c\/li\u003e\n  \u003cli\u003eDesalination\u003c\/li\u003e\n  \u003cli\u003eReversed Osmosis - Water treatment\u003c\/li\u003e\n  \u003cli\u003eSurface water intake\u003c\/li\u003e\n  \u003cli\u003eDrinking water treatment\u003c\/li\u003e\n  \u003cli\u003eWater distribution\u003c\/li\u003e\n  \u003cli\u003eIrrigation\u003c\/li\u003e\n  \u003cli\u003eSolar water solutions\u003c\/li\u003e\n  \u003cli\u003eCommunity water supply\u003c\/li\u003e\n  \u003cli\u003eRotor \u0026amp; spray irrigation\u003c\/li\u003e\n  \u003cli\u003eGround water transfer\u003c\/li\u003e\n  \u003cli\u003ePivot\u003c\/li\u003e\n  \u003cli\u003eSolar boosting and water supply solutions\u003c\/li\u003e\n  \u003cli\u003eControls and digital groundwater management\u003c\/li\u003e\n  \u003cli\u003eSolar controls and digital water management\u003c\/li\u003e\n  \u003cli\u003eSolar water treatment fertigation and dosing\u003c\/li\u003e\n  \u003cli\u003eAgriculture solar solutions\u003c\/li\u003e\n  \u003cli\u003eLivestock watering with solar solutions\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eProduct Name\u003c\/td\u003e\n\u003ctd\u003eGrundfos CRN 3-21 A-FGJ-A-V-HQQV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eProduct Number\u003c\/td\u003e\n\u003ctd\u003e96480979\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eEAN Number\u003c\/td\u003e\n\u003ctd\u003e5700395486445\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePump Type\u003c\/td\u003e\n\u003ctd\u003eVertical multistage in-line centrifugal pump\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eRated Flow\u003c\/td\u003e\n\u003ctd\u003e3 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eRated Head\u003c\/td\u003e\n\u003ctd\u003e103.6 m\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMaximum Head\u003c\/td\u003e\n\u003ctd\u003e139.9 m\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eStages\u003c\/td\u003e\n\u003ctd\u003e21\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eImpellers\u003c\/td\u003e\n\u003ctd\u003e21\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eNumber of Reduced-Diameter Impellers\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eLow NPSH\u003c\/td\u003e\n\u003ctd\u003eN\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePump Speed\u003c\/td\u003e\n\u003ctd\u003e2899 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePump Orientation\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eShaft Seal Arrangement\u003c\/td\u003e\n\u003ctd\u003eSingle\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePrimary Shaft Seal\u003c\/td\u003e\n\u003ctd\u003eHQQV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCode for Shaft Seal\u003c\/td\u003e\n\u003ctd\u003eHQQV\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePump Version\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePumped Liquid\u003c\/td\u003e\n\u003ctd\u003eWater\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eLiquid Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-20 to 90 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSelected Liquid Temperature\u003c\/td\u003e\n\u003ctd\u003e20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDensity\u003c\/td\u003e\n\u003ctd\u003e998.2 kg\/m³\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBase Material\u003c\/td\u003e\n\u003ctd\u003eStainless steel, EN 1.4408 \/ AISI 316\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eImpeller Material\u003c\/td\u003e\n\u003ctd\u003eStainless steel, EN 1.4401 \/ AISI 316\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBearing\u003c\/td\u003e\n\u003ctd\u003eSIC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMaterial Code\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eRubber Components Code\u003c\/td\u003e\n\u003ctd\u003eV (FKM)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMaximum Ambient Temperature\u003c\/td\u003e\n\u003ctd\u003e60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMaximum Operating Pressure\u003c\/td\u003e\n\u003ctd\u003e25 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax Pressure at Stated Temperature\u003c\/td\u003e\n\u003ctd\u003e25 bar \/ 90 °C; 25 bar \/ -20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConnection Type\u003c\/td\u003e\n\u003ctd\u003eDIN \/ ANSI \/ JIS\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConnection Code\u003c\/td\u003e\n\u003ctd\u003eFGJ\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInlet Connection Size\u003c\/td\u003e\n\u003ctd\u003eDN 25\/32 (1 1\/4 inch)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eOutlet Connection Size\u003c\/td\u003e\n\u003ctd\u003eDN 25\/32 (1 1\/4 inch)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePressure Rating for Connection\u003c\/td\u003e\n\u003ctd\u003ePN 25\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eFlange Rating Inlet\u003c\/td\u003e\n\u003ctd\u003e300 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eFlange Size for Motor\u003c\/td\u003e\n\u003ctd\u003eFT115\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTerminal Box Position\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMotor Standard\u003c\/td\u003e\n\u003ctd\u003eIEC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMotor Type\u003c\/td\u003e\n\u003ctd\u003e90LE\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eRated Power (P2)\u003c\/td\u003e\n\u003ctd\u003e2.2 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePower Required by Pump (P2)\u003c\/td\u003e\n\u003ctd\u003e2.2 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMains Frequency\u003c\/td\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eRated Voltage\u003c\/td\u003e\n\u003ctd\u003e3 x 220-240D\/380-415Y V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e8.00\/4.60 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eStarting Current\u003c\/td\u003e\n\u003ctd\u003e840-920 %\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCos Phi \/ Power Factor\u003c\/td\u003e\n\u003ctd\u003e0.86-0.80\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eRated Speed\u003c\/td\u003e\n\u003ctd\u003e2890-2910 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eIE Efficiency Class\u003c\/td\u003e\n\u003ctd\u003eIE3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMotor Efficiency at Full Load\u003c\/td\u003e\n\u003ctd\u003e85.9 %\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMotor Efficiency at 3\/4 Load\u003c\/td\u003e\n\u003ctd\u003e88.2-87.2 %\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMotor Efficiency at 1\/2 Load\u003c\/td\u003e\n\u003ctd\u003e88.0-85.5 %\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eEnclosure Class (IEC 34-5)\u003c\/td\u003e\n\u003ctd\u003eIP55 Dust\/Jetting\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInsulation Class (IEC 85)\u003c\/td\u003e\n\u003ctd\u003eF\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBuilt-in Motor Protection\u003c\/td\u003e\n\u003ctd\u003eNONE\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMotor No.\u003c\/td\u003e\n\u003ctd\u003e85U01908\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eFrequency Converter\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eApprovals\u003c\/td\u003e\n\u003ctd\u003eCE, EAC, UKCA, SEPRO, RCM\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eApprovals for Drinking Water\u003c\/td\u003e\n\u003ctd\u003eWRAS, ACS\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCurve Tolerance\u003c\/td\u003e\n\u003ctd\u003eISO9906:2012 3B\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMinimum Efficiency Index (MEI)\u003c\/td\u003e\n\u003ctd\u003e≥ 0.70\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e42.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eGross Weight\u003c\/td\u003e\n\u003ctd\u003e45.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eShipping Volume\u003c\/td\u003e\n\u003ctd\u003e0.13 m³\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eTW\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCustom Tariff No.\u003c\/td\u003e\n\u003ctd\u003e8413709062\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePrice\u003c\/td\u003e\n\u003ctd\u003eAUD 5203\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eProduct Datasheet PDF\u003c\/td\u003e\n    \u003ctd\u003e\u003ca href=\"https:\/\/product-selection.grundfos.com\/content\/grundfos\/au\/en\/templates\/product-pages\/variant-page.print-getpdf.ticketresults.pdf?jobid=7c783348-87cc-4dc9-a4bb-39b83b256657\u0026amp;documentName=96480979_CRN_321_AFGJAVHQQV\" target=\"_blank\" rel=\"noopener\"\u003eDownload PDF\u003c\/a\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e","brand":"Grundfos","offers":[{"title":"Default Title","offer_id":44890755563629,"sku":"96480979","price":3577.06,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/96480979-product.jpg?v=1774317788","url":"https:\/\/pumptastic.com.au\/products\/grundfos-crn-3-21-a-fgj-a-v-hqqv-vertical-multistage-centrifugal-pump-96480979","provider":"Pumptastic","version":"1.0","type":"link"}