{"product_id":"grundfos-crn-15-8-a-fgj-a-v-hqqv-vertical-multistage-centrifugal-pump-96502055","title":"Grundfos CRN 15-8 A-FGJ-A-V-HQQV Vertical Multistage Centrifugal Pump – 96502055 (3 x 380-415D\/660-690YD)","description":"\u003cp\u003eThe Grundfos CRN 15-8 A-FGJ-A-V-HQQV is a vertical, non-self-priming, multistage in-line centrifugal pump designed for demanding commercial, industrial, and water treatment applications. Built with high-grade AISI 316 stainless steel wetted components and fitted with an HQQV shaft seal, this pump delivers reliable performance for clean water transfer, pressure boosting, process systems, irrigation, and solar water supply solutions.\u003c\/p\u003e\n\n\u003ch3\u003eSuitable Applications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial heating\u003c\/li\u003e\n  \u003cli\u003eCommercial air conditioning\u003c\/li\u003e\n  \u003cli\u003eCommercial water pressure boosting\u003c\/li\u003e\n  \u003cli\u003eDistrict heating\u003c\/li\u003e\n  \u003cli\u003eDistrict cooling\u003c\/li\u003e\n  \u003cli\u003eMachining\u003c\/li\u003e\n  \u003cli\u003eWash and clean\u003c\/li\u003e\n  \u003cli\u003eProcess liquids transfer\u003c\/li\u003e\n  \u003cli\u003eIndustrial heating\u003c\/li\u003e\n  \u003cli\u003eCooling\u003c\/li\u003e\n  \u003cli\u003eIndustrial water supply\u003c\/li\u003e\n  \u003cli\u003eIndustrial wastewater\u003c\/li\u003e\n  \u003cli\u003eIndustrial process water treatment\u003c\/li\u003e\n  \u003cli\u003eDesalination\u003c\/li\u003e\n  \u003cli\u003eReverse osmosis water treatment\u003c\/li\u003e\n  \u003cli\u003eSurface water intake\u003c\/li\u003e\n  \u003cli\u003eDrinking water treatment\u003c\/li\u003e\n  \u003cli\u003eWater distribution\u003c\/li\u003e\n  \u003cli\u003eIrrigation\u003c\/li\u003e\n  \u003cli\u003eSolar water solutions\u003c\/li\u003e\n  \u003cli\u003eCommunity water supply\u003c\/li\u003e\n  \u003cli\u003eRotor \u0026amp; spray irrigation\u003c\/li\u003e\n  \u003cli\u003eGround water transfer\u003c\/li\u003e\n  \u003cli\u003ePivot irrigation\u003c\/li\u003e\n  \u003cli\u003eSolar boosting and water supply solutions\u003c\/li\u003e\n  \u003cli\u003eControls and digital groundwater management\u003c\/li\u003e\n  \u003cli\u003eSolar controls and digital water management\u003c\/li\u003e\n  \u003cli\u003eSolar water treatment fertigation and dosing\u003c\/li\u003e\n  \u003cli\u003eAgriculture solar solutions\u003c\/li\u003e\n  \u003cli\u003eLivestock watering with solar solutions\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"8\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCRN 15-8 A-FGJ-A-V-HQQV\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e96502055\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5700396234564\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePump Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical multistage in-line centrifugal pump\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Head\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 m\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Head\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e113 m\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePump Speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2919 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2910–2920 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStages\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpellers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReduced-Diameter Impellers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePump Orientation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShaft Seal Arrangement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShaft Seal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHQQV\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePumped Liquid\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWater\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLiquid Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 to 90 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSelected Liquid Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDensity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e998.2 kg\/m³\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Operating Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Pressure at Stated Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 bar \/ 90 °C, 25 bar \/ -20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN \/ ANSI \/ JIS\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFGJ\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInlet Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDN 50 (2 inch)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutlet Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDN 50 (2 inch)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePressure Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePN 25\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFlange Rating Inlet\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStainless steel (EN 1.4408 \/ AISI 316)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpeller Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStainless steel (EN 1.4401 \/ AISI 316)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBearing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Standard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e132SB\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power (P2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Required by Pump (P2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 x 380-415D \/ 660-690Y V\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14.4–14.0 \/ 8.30–8.10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStarting Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e780–910 %\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Factor (Cos φ)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.88–0.82\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Efficiency Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIE3\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Efficiency at Full Load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90.1–90.4 %\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Efficiency at 3\/4 Load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90.8–90.9 %\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Efficiency at 1\/2 Load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90.8–90.4 %\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP55\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuilt-in Motor Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePTC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85U17522\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFlange Size for Motor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFF265\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Box Position\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Converter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE, EAC, UKCA, SEPRO\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrinking Water Approvals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWRAS, ACS\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurve Tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISO9906:2012 3B\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Efficiency Index (MEI)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≥ 0.70\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Ambient Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e103 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGross Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShipping Volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.285 m³\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTaiwan\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCustom Tariff Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e84137090621436561\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"8\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eDocument\u003c\/th\u003e\n      \u003cth\u003eDownload Link\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Datasheet \/ Technical PDF\u003c\/td\u003e\n      \u003ctd\u003e\u003ca href=\"https:\/\/product-selection.grundfos.com\/content\/grundfos\/au\/en\/templates\/product-pages\/variant-page.print-getpdf.ticketresults.pdf?jobid=6ec2aa6c-0793-42b8-8eb1-60b51bb489a4\u0026amp;documentName=96502055_CRN_158_AFGJAVHQQV\" target=\"_blank\"\u003eDownload PDF\u003c\/a\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Grundfos","offers":[{"title":"Default Title","offer_id":44903856144493,"sku":"96502055","price":7662.88,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/96502055-product.jpg?v=1774591053","url":"https:\/\/pumptastic.com.au\/products\/grundfos-crn-15-8-a-fgj-a-v-hqqv-vertical-multistage-centrifugal-pump-96502055","provider":"Pumptastic","version":"1.0","type":"link"}