{"product_id":"davey-xj90t-water-pressure-system-with-torrium2-xj90t","title":"Davey XJ90T Water Pressure System with Torrium2 – XJ90T","description":"\u003cp\u003e\n  The Davey XJ90T is a compact, single‑stage jet assisted centrifugal pump with a Torrium2 controller, designed for home pressure systems drawing water from below pump level (e.g., buried or partially buried tanks). It delivers a maximum flow of 90 L\/min and a maximum head of 46 m. The pump features a glass filled noryl casing, a glass filled polycarbonate impeller, a carbon\/ceramic mechanical seal, and a 303 stainless steel shaft. The single‑phase TEFC motor (1.1 kW P2, IP55, Class F) includes built‑in thermal overload protection. The Torrium2 controller provides constant pressure, loss of prime protection, and adaptive technology to prevent cycling. Inlet size is 1¼” BSP(F), outlet 1” BSP(M). Complies with AS\/NZS 4020 for drinking water contact.\n\u003c\/p\u003e\n\n\u003ch3\u003eSuitable Applications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eHousehold and domestic water supply\u003c\/li\u003e\n  \u003cli\u003eFarming and agricultural water systems\u003c\/li\u003e\n  \u003cli\u003eIrrigation and turf watering systems\u003c\/li\u003e\n  \u003cli\u003eAutomatic general water transfer\u003c\/li\u003e\n  \u003cli\u003eDomestic irrigation from shallow wells or sand spears\u003c\/li\u003e\n  \u003cli\u003eOverhead or high tank filling\u003c\/li\u003e\n  \u003cli\u003ePressure boosting\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n  \u003ctr\u003e\n    \u003cth\u003eProduct Name\u003c\/th\u003e\n    \u003ctd\u003eDavey XJ90T Water Pressure System with Torrium2\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003cth\u003eProduct Number\u003c\/th\u003e\n    \u003ctd\u003eXJ90T\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003cth\u003eEAN\u003c\/th\u003e\n    \u003ctd\u003e—\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003cth\u003ePump Type\u003c\/th\u003e\n    \u003ctd\u003eSingle‑stage jet assisted centrifugal pump with Torrium2 controller\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003cth\u003eMaximum Flow\u003c\/th\u003e\n    \u003ctd\u003e90 L\/min (5.4 m³\/h)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003cth\u003eMaximum Head\u003c\/th\u003e\n    \u003ctd\u003e46 m\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003cth\u003eMaximum Suction Lift\u003c\/th\u003e\n    \u003ctd\u003e7 m\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003cth\u003eMaximum System Pressure\u003c\/th\u003e\n    \u003ctd\u003e480 kPa\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003cth\u003eMaximum Water Temperature\u003c\/th\u003e\n    \u003ctd\u003e50 °C\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003cth\u003eMinimum Water Temperature\u003c\/th\u003e\n    \u003ctd\u003e1 °C\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003cth\u003eMaximum Ambient Temperature\u003c\/th\u003e\n    \u003ctd\u003e50 °C\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003cth\u003eInlet Connection\u003c\/th\u003e\n    \u003ctd\u003e1¼” BSP(F)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003cth\u003eOutlet Connection\u003c\/th\u003e\n    \u003ctd\u003e1” BSP(M)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003cth\u003ePump Casing Material\u003c\/th\u003e\n    \u003ctd\u003eGlass filled noryl\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003cth\u003eImpeller Material\u003c\/th\u003e\n    \u003ctd\u003eGlass filled polycarbonate\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003cth\u003ePump Shaft Material\u003c\/th\u003e\n    \u003ctd\u003e303 stainless steel\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003cth\u003eMechanical Seal\u003c\/th\u003e\n    \u003ctd\u003eCarbon (rotating) \/ Ceramic (stationary) \/ Nitrile rubber\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003cth\u003eMotor Power (P2)\u003c\/th\u003e\n    \u003ctd\u003e1.1 kW\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003cth\u003eMotor Power (P1)\u003c\/th\u003e\n    \u003ctd\u003e1.4 kW\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003cth\u003eVoltage \/ Frequency\u003c\/th\u003e\n    \u003ctd\u003e220‑240 V, 50 Hz\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003cth\u003ePhase\u003c\/th\u003e\n    \u003ctd\u003eSingle\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003cth\u003eFull Load Current\u003c\/th\u003e\n    \u003ctd\u003e6.6 A\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003cth\u003eLocked Rotor Current\u003c\/th\u003e\n    \u003ctd\u003e28 A\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003cth\u003eInsulation Class\u003c\/th\u003e\n    \u003ctd\u003eF\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003cth\u003eEnclosure Class\u003c\/th\u003e\n    \u003ctd\u003eIP55\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003cth\u003eMotor Speed\u003c\/th\u003e\n    \u003ctd\u003e2850 rpm\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003cth\u003eStarting Method\u003c\/th\u003e\n    \u003ctd\u003ePermanent Split Capacitor (P.S.C.)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003cth\u003eTorrium2 Controller\u003c\/th\u003e\n    \u003ctd\u003eVoltage: 110‑240V ±10%, IP56, Max load current 10A\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003cth\u003eNet Weight\u003c\/th\u003e\n    \u003ctd\u003e15 kg\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003cth\u003eDimensions (L × W × H)\u003c\/th\u003e\n    \u003ctd\u003e505 × 265 × 185 mm (approx.)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003cth\u003eWarranty\u003c\/th\u003e\n    \u003ctd\u003e2 years\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003cth\u003eApprovals\u003c\/th\u003e\n    \u003ctd\u003eAS\/NZS 4020, ISO 9001, ISO 14001\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"pdf-table\"\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eXJ Water Pressure System Datasheet\u003c\/td\u003e\n    \u003ctd\u003e\u003ca href=\"https:\/\/cdn.intelligencebank.com\/au\/share\/BnKJ1e\/8BJpv\/rbov8\/original\/XJ50T_XJ70T_XJ90T_Datasheet\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eTorrium2 Water Pressure Systems Installation \u0026amp; Operating Instructions\u003c\/td\u003e\n    \u003ctd\u003e\u003ca href=\"https:\/\/cdn.intelligencebank.com\/au\/share\/BnKJ1e\/8BzXy\/O4Ok3\/original\/WPS_wTorrium_IM\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cstrong\u003eInstallation Note:\u003c\/strong\u003e Installations with suction lift require a good quality foot valve – remove in‑built check valve. Prime by filling pump body and suction line through priming plug hole. For total system pressures of 600 kPa with mains pressure exceeding 100 kPa, a break tank or Davey HS system is required.\u003c\/p\u003e","brand":"Davey","offers":[{"title":"Default Title","offer_id":47789024141,"sku":"XJ90T","price":1160.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/products\/XJ50T_1_8839470d-f772-4d1f-8cb9-bf7b1306d322.jpg?v=1546221720","url":"https:\/\/pumptastic.com.au\/products\/davey-xj90t-water-pressure-system-with-torrium2-xj90t","provider":"Pumptastic","version":"1.0","type":"link"}