{"product_id":"davey-hs60-08t-torrium2-water-pressure-system-hs60-08t","title":"Davey HS60-08T Torrium2 Water Pressure System – HS60-08T","description":"\u003cp\u003e\n  The Davey HS60-08T is a compact, four‑stage horizontal multistage pressure system with a Torrium2 controller, delivering constant flow without cycling. It delivers a maximum flow of 110 L\/min and a maximum head of 50 m. The pump features a 304 stainless steel casing and backplate, glass filled polycarbonate “half‑blind” impellers, patented floating neck rings for high efficiency, an air purging valve, and a carbon\/ceramic mechanical seal with nitrile rubber o‑rings. The TEFC motor (0.76 kW P2, IP55, Class F) includes built‑in thermal overload protection. The Torrium2 controller provides adaptive constant pressure, loss of prime protection, and over‑temperature cut‑out. Inlet size is 1¼” BSP(F), outlet size is 1” BSP(F). The system complies with AS\/NZS 4020 for drinking water.\n\u003c\/p\u003e\n\n\u003ch3\u003eSuitable Applications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eHousehold water supply (single or multi‑storey homes)\u003c\/li\u003e\n  \u003cli\u003eIrrigation\u003c\/li\u003e\n  \u003cli\u003eWater transfer\u003c\/li\u003e\n  \u003cli\u003eWashing systems\u003c\/li\u003e\n  \u003cli\u003ePressure boosting\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n  \u003ctr\u003e\n    \u003cth\u003eProduct Name\u003c\/th\u003e\n    \u003ctd\u003eDavey HS60-08T Torrium2 Water Pressure System\n  \u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003cth\u003eProduct Number\u003c\/th\u003e\n    \u003ctd\u003eHS60-08T\n  \u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003cth\u003eEAN\u003c\/th\u003e\n    \u003ctd\u003e—\n  \u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003cth\u003ePump Type\u003c\/th\u003e\n    \u003ctd\u003eHorizontal multistage centrifugal pump with Torrium2 controller (4 stage)\n  \u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003cth\u003eNumber of Stages\u003c\/th\u003e\n    \u003ctd\u003e4\n  \u003c\/td\u003e\n\u003c\/tr\u003e\n  \n    \u003cth\u003eMaximum Flow\u003c\/th\u003e\n    \u003ctd\u003e110 L\/min (6.6 m³\/h)\n  \u003c\/td\u003e\n\u003ctr\u003e\n  \u003c\/tr\u003e\n\u003ctr\u003e\n    \u003cth\u003eMaximum Head\u003c\/th\u003e\n    \u003ctd\u003e50 m\n  \u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003cth\u003eMaximum Suction Lift\u003c\/th\u003e\n    \u003ctd\u003e6 m\n  \u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003ctr\u003e\n    \u003cth\u003eMaximum System Pressure\u003c\/th\u003e\n    \u003ctd\u003e700 kPa (7 bar)\n  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n  \u003ctr\u003e\n    \u003cth\u003eMaximum Water Temperature\u003c\/th\u003e\n    \u003ctd\u003e50 °C\n  \u003c\/td\u003e\n\u003c\/tr\u003e\u003ctr\u003e\n  \u003c\/tr\u003e\u003ctr\u003e\n    \u003cth\u003eMinimum Water Temperature\u003c\/th\u003e\n    \u003ctd\u003e1 °C\n  \u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003cth\u003eMaximum Ambient Temperature\u003c\/th\u003e\n    \u003ctd\u003e50 °C\n  \u003c\/td\u003e\n\u003c\/tr\u003e\n  \n    \u003cth\u003eInlet Connection\u003c\/th\u003e\n    \u003ctd\u003e1¼” BSP(F)\n  \n  \u003c\/td\u003e\u003ctr\u003e\n    \u003cth\u003eOutlet Connection\u003c\/th\u003e\n    \u003ctd\u003e1” BSP(F)\n  \u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003cth\u003eCasing \/ Backplate Material\u003c\/th\u003e\n    \u003ctd\u003e304 stainless steel\n  \u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003cth\u003eImpeller Material\u003c\/th\u003e\n    \u003ctd\u003eGlass filled polycarbonate\n  \u003c\/td\u003e\n\u003c\/tr\u003e\n  \n    \u003cth\u003ePump Shaft Material\u003c\/th\u003e\n    \u003ctd\u003e303 stainless steel\n  \n  \u003c\/td\u003e\u003ctr\u003e\n    \u003cth\u003eMechanical Seal\u003c\/th\u003e\n    \u003ctd\u003eCarbon (rotating) \/ Ceramic (stationary) \/ Nitrile rubber\n  \u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003cth\u003eMotor Power (P2)\u003c\/th\u003e\n    \u003ctd\u003e0.76 kW\n  \u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctd\u003e\n    \u003c\/td\u003e\u003cth\u003eMotor Power (P1)\u003c\/th\u003e\n    \u003ctd\u003e1.1 kW\n  \n  \u003c\/td\u003e\u003ctr\u003e\n    \u003cth\u003eVoltage \/ Frequency\u003c\/th\u003e\n    \u003ctd\u003e220‑240 V, 50 Hz\n  \u003c\/td\u003e\n  \u003c\/tr\u003e\u003ctr\u003e\n    \u003cth\u003ePhase\u003c\/th\u003e\n    \u003ctd\u003eSingle\n  \u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003cth\u003eFull Load Current\u003c\/th\u003e\n    \u003ctd\u003e4.9 A\n  \u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003cth\u003eLocked Rotor Current\u003c\/th\u003e\n    \u003ctd\u003e18.0 A\n  \u003c\/td\u003e\n\u003c\/tr\u003e\u003ctr\u003e\n  \u003c\/tr\u003e\u003ctr\u003e\n    \u003cth\u003eInsulation Class\u003c\/th\u003e\n    \u003ctd\u003eF\n  \u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003cth\u003eEnclosure Class\u003c\/th\u003e\n    \u003ctd\u003eIP55\n  \u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003cth\u003eMotor Speed\u003c\/th\u003e\n    \u003ctd\u003e2850 rpm\n  \u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003cth\u003eTorrium2 Max Load Current\u003c\/th\u003e\n    \u003ctd\u003e10 A\n  \u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003cth\u003eTorrium2 Max Motor Size\u003c\/th\u003e\n    \u003ctd\u003e1.8 kW (at 240V input)\n  \u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003cth\u003eNet Weight\u003c\/th\u003e\n    \u003ctd\u003eNot specified (refer to datasheet)\n  \u003c\/td\u003e\n\u003c\/tr\u003e\u003ctr\u003e\n  \u003c\/tr\u003e\u003ctr\u003e\n    \u003cth\u003eWarranty\u003c\/th\u003e\n    \u003ctd\u003e2 years\n  \u003c\/td\u003e\n\u003c\/tr\u003e\u003ctr\u003e\n  \u003c\/tr\u003e\u003ctr\u003e\n    \u003cth\u003eApprovals\u003c\/th\u003e\n    \u003ctd\u003eAS\/NZS 4020, ISO 9001, ISO 14001\n  \u003c\/td\u003e\n\u003c\/tr\u003e\n\n\n\u003ch3\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"pdf-table\"\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eHS Water Pressure Systems Datasheet\n    \u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/cdn.intelligencebank.com\/au\/share\/BnKJ1e\/8BJpv\/bleXN\/original\/HSwTorrium_Datasheet\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\n  \u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eTorrium2 Controller Datasheet\n    \u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/cdn.intelligencebank.com\/au\/share\/BnKJ1e\/8BJpv\/k78k9\/original\/Torrium2_Datasheet\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\n  \u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eTorrium2 Water Pressure Systems Installation \u0026amp; Operating Instructions\n    \u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/cdn.intelligencebank.com\/au\/share\/BnKJ1e\/8BzXy\/O4Ok3\/original\/WPS_wTorrium_IM\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\n  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"Davey","offers":[{"title":"Default Title","offer_id":42749848387693,"sku":"HS60-08T","price":1095.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/MODEL_91c671cf-a237-424c-894c-8cd44abfa12e.png?v=1754544549","url":"https:\/\/pumptastic.com.au\/products\/davey-hs60-08t-torrium2-water-pressure-system-hs60-08t","provider":"Pumptastic","version":"1.0","type":"link"}