{"title":"Shop Pump Controllers","description":"\u003cp\u003eAt PUMPTASTIC™, we understand that your pump system or your pump’s performance relies heavily on the controller that ensures precision, efficiency, and operational reliability. Be it managing a domestic pressure system, an irrigation setup, pool system, or even an industrial water transfer application, your pump controller has to be of high quality to ensure everything runs safely, efficiently, and requires minimal manual supervision.  \u003c\/p\u003e\n\u003cp\u003eAs one of Australia’s prominent online stores for pumps and pump accessories, we take pride in offering a wide range of top-grade pump controllers from basic automatic pressure switches to advanced variable speed drives (VSDs) and smart monitoring systems. We service homes, farms, construction sites, commercial properties, and everything in between.  \u003c\/p\u003e\n\u003cp\u003eChoosing PUMPTASTIC™ means you’re selecting unmatched and steadfast reliability, unparalleled support, and dedication that complements yours.  \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eWhat Is a Pump Controller? \u003c\/strong\u003e\u003c\/span\u003e \u003c\/p\u003e\n\u003cp\u003ePump controllers are devices that manage pumps. They may monitor water levels, dry run conditions, flow rate, pressure, temperature, or even power draw depending on the application. A controller streamlining functions ensures the pump only activates when necessary, providing protection from damage and optimizing energy usage.\u003c\/p\u003e\n\u003cp\u003eSome of the most common pump controller types include:  \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure controllers \u003c\/strong\u003e– Used in domestic water systems to ensure smooth water flow while preventing dry run scenarios.  \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFloat switch controller\u003c\/strong\u003es – Best suited for wastewater and tank filling systems where predetermined water levels trigger pump operation.  \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable Speed Drives (VSDs\u003c\/strong\u003e) – Implemented in more sophisticated systems to manage energy consumption, balance efficiency, and control motor speed for precise flow.  \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIrrigation and bore controllers \u003c\/strong\u003e– Tailored for commercial and agricultural watering needs.  \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote monitoring controllers\u003c\/strong\u003e – Provides access to pump system information, enabling control and receiving alerts through smartphones or computers.  \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAs in all other cases, the appropriate controller enhances the system value by providing automation, system protection, and saving costs over time.\u003c\/p\u003e\n\u003chr data-start=\"2480\" data-end=\"2483\"\u003e\n\u003ch3 data-start=\"2485\" data-end=\"2531\"\u003eWhy Buy Pump Controllers from PUMPTASTIC™?\u003c\/h3\u003e\n\u003cp data-start=\"2533\" data-end=\"2773\"\u003eThere are plenty of suppliers out there, but very few understand pumps the way we do. At PUMPTASTIC™, we \u003cstrong data-start=\"2638\" data-end=\"2698\"\u003especialise exclusively in pumps and pump-related systems\u003c\/strong\u003e, meaning we stock and recommend products that we would personally install.\u003c\/p\u003e\n\u003cp data-start=\"2775\" data-end=\"2864\"\u003eHere's why Australians across the country turn to PUMPTASTIC™ for pump control solutions:\u003c\/p\u003e\n\u003ch4 data-start=\"2866\" data-end=\"2895\"\u003e✅ Specialist Knowledge\u003c\/h4\u003e\n\u003cp data-start=\"2896\" data-end=\"3096\"\u003eOur team has years of experience across domestic, agricultural, and commercial pump systems. We understand the nuances between systems and can recommend \u003cstrong data-start=\"3049\" data-end=\"3095\"\u003ethe ideal controller for your unique setup\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch4 data-start=\"3098\" data-end=\"3126\"\u003e✅ Quality Brands Only\u003c\/h4\u003e\n\u003cp data-start=\"3127\" data-end=\"3194\"\u003eWe stock \u003cstrong data-start=\"3136\" data-end=\"3183\"\u003eproven, high-quality pump controller brands\u003c\/strong\u003e including:\u003c\/p\u003e\n\u003cul data-start=\"3196\" data-end=\"3305\"\u003e\n\u003cli data-start=\"3196\" data-end=\"3207\"\u003e\n\u003cp data-start=\"3198\" data-end=\"3207\"\u003e\u003cstrong data-start=\"3198\" data-end=\"3207\"\u003eDavey\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3208\" data-end=\"3222\"\u003e\n\u003cp data-start=\"3210\" data-end=\"3222\"\u003e\u003cstrong data-start=\"3210\" data-end=\"3222\"\u003eGrundfos\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3223\" data-end=\"3243\"\u003e\n\u003cp data-start=\"3225\" data-end=\"3243\"\u003e\u003cstrong data-start=\"3225\" data-end=\"3243\"\u003eOnga \/ Pentair\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3244\" data-end=\"3256\"\u003e\n\u003cp data-start=\"3246\" data-end=\"3256\"\u003e\u003cstrong data-start=\"3246\" data-end=\"3256\"\u003eBianco\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3257\" data-end=\"3268\"\u003e\n\u003cp data-start=\"3259\" data-end=\"3268\"\u003e\u003cstrong data-start=\"3259\" data-end=\"3268\"\u003eReefe\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3269\" data-end=\"3281\"\u003e\n\u003cp data-start=\"3271\" data-end=\"3281\"\u003e\u003cstrong data-start=\"3271\" data-end=\"3281\"\u003eLowara\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3282\" data-end=\"3305\"\u003e\n\u003cp data-start=\"3284\" data-end=\"3305\"\u003e\u003cstrong data-start=\"3284\" data-end=\"3305\"\u003eFranklin Electric\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3307\" data-end=\"3467\"\u003eThese manufacturers are trusted throughout the industry for their \u003cstrong data-start=\"3373\" data-end=\"3417\"\u003eengineering excellence, warranty support\u003c\/strong\u003e, and \u003cstrong data-start=\"3423\" data-end=\"3466\"\u003ecompatibility with Australian standards\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch4 data-start=\"3469\" data-end=\"3506\"\u003e✅ Fast Australia-Wide Delivery\u003c\/h4\u003e\n\u003cp data-start=\"3507\" data-end=\"3711\"\u003eFrom metro Perth to rural Queensland, we ship quickly and reliably. Orders placed before midday are usually shipped the same day, and we service \u003cstrong data-start=\"3652\" data-end=\"3710\"\u003eboth residential and commercial clients Australia-wide\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch4 data-start=\"3713\" data-end=\"3741\"\u003e✅ Competitive Pricing\u003c\/h4\u003e\n\u003cp data-start=\"3742\" data-end=\"3950\"\u003eWe offer \u003cstrong data-start=\"3751\" data-end=\"3774\"\u003etrade-level pricing\u003c\/strong\u003e on many items and bulk discounts for repeat customers, contractors, and facility managers. As an online-first business, we pass our \u003cstrong data-start=\"3907\" data-end=\"3949\"\u003eoperational savings directly on to you\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch4 data-start=\"3952\" data-end=\"3979\"\u003e✅ End-to-End Support\u003c\/h4\u003e\n\u003cp data-start=\"3980\" data-end=\"4176\"\u003eNot sure what controller suits your system? Speak to our team. We provide pre-sale guidance, post-sale support, and troubleshooting help. We're not just a retailer—we’re a partner in your project.\u003c\/p\u003e","products":[{"product_id":"grundfos-lc-231-2-x-1-9-dol-pi-pumps-controller","title":"Grundfos LC 231 2 x 1-9 DOL PI Pumps Controller","description":"\u003cp\u003eThe LC 231 pump controllers are designed for level control, monitoring and protection of Grundfos pumping systems oneÂ pumps or two pumps starting direct-on-line.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures include\u003c\/strong\u003e:\u003cbr\u003eâ€¢ Supports both empty and fill applications\u003cbr\u003eâ€¢ \u0026gt;For use with analogue (eg level transmitter) or digital sensor (eg float switch)\u003cbr\u003eâ€¢ Grundfos Go support via Bluetooth\u003cbr\u003eâ€¢ Usage, alarm and warning log\u003cbr\u003eâ€¢ BMS options (CIM module required)\u003c\/p\u003e\n\u003ctable class=\"spec-table\"\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eProduct Name\u003c\/td\u003e\n    \u003ctd\u003eLC 231 2 x 1-9 DOL PI\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eProduct Number\u003c\/td\u003e\n    \u003ctd\u003e99369650\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eEAN Number\u003c\/td\u003e\n    \u003ctd\u003e5713827986697\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003ePrice\u003c\/td\u003e\n    \u003ctd\u003eAUD 1916\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eSuitable For\u003c\/td\u003e\n    \u003ctd\u003eWater treatment - Commercial buildings, Drinking water treatment, Wastewater transport, Flood control, Wastewater treatment\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eNumber of Pumps\u003c\/td\u003e\n    \u003ctd\u003e2\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eMethod of Start\u003c\/td\u003e\n    \u003ctd\u003eDirect-on-line (DOL)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eRated Voltage\u003c\/td\u003e\n    \u003ctd\u003e1 x 110-240 V [3 x 200-460 V]\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eRated Current\u003c\/td\u003e\n    \u003ctd\u003e1-9 A\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eMains Frequency\u003c\/td\u003e\n    \u003ctd\u003e50 \/ 60 Hz\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eEnclosure Class\u003c\/td\u003e\n    \u003ctd\u003eIP54\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eCabinet Material\u003c\/td\u003e\n    \u003ctd\u003ePlastic\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eAmbient Temperature Range\u003c\/td\u003e\n    \u003ctd\u003e-25 â€¦ 40 °C\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eCabinet Mounting\u003c\/td\u003e\n    \u003ctd\u003eWall mounting\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eEarth Connection\u003c\/td\u003e\n    \u003ctd\u003eN, PE\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eBack-up Fuse Required\u003c\/td\u003e\n    \u003ctd\u003e35 A\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eCurrent Measurement\u003c\/td\u003e\n    \u003ctd\u003eYes\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eRequired Cos Phi (Full Load)\u003c\/td\u003e\n    \u003ctd\u003e0.86-1.00\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eNet Weight\u003c\/td\u003e\n    \u003ctd\u003e2 kg\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eGross Weight\u003c\/td\u003e\n    \u003ctd\u003e2.79 kg\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eShipping Volume\u003c\/td\u003e\n    \u003ctd\u003e0.015 m³\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eCountry of Origin\u003c\/td\u003e\n    \u003ctd\u003eAustralia (AU)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eApprovals\u003c\/td\u003e\n    \u003ctd\u003eCE, EAC, UKCA, MOROCCO, RCM\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eCustom Tariff No.\u003c\/td\u003e\n    \u003ctd\u003e8537109019\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eDanish VVS No.\u003c\/td\u003e\n    \u003ctd\u003e391378580\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eSwedish RSK No.\u003c\/td\u003e\n    \u003ctd\u003e5886184\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eFinnish LVI No.\u003c\/td\u003e\n    \u003ctd\u003e4981136\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003eExplore more of our \u003ca href=\"https:\/\/pumptastic.com.au\/collections\/pump-controllers?sort_by=price-ascending\" title=\"Grundfos Pumps Controller\"\u003eGrundfos Pumps Controller\u003c\/a\u003eÂ at \u003ca title=\"Pumptastic\" href=\"https:\/\/pumptastic.com.au\/\"\u003ePumptasticÂ®\u003c\/a\u003e.\u003c\/span\u003e\u003c\/p\u003e","brand":"Grundfos","offers":[{"title":"Default Title","offer_id":42631291961453,"sku":"99369650","price":1521.37,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/PUMPS_CONTROLLER.png?v=1757573228"},{"product_id":"grundfos-lc-231-1-x-1-12-dol-pi-pumps-controller","title":"Grundfos LC 231 1 x 1-12 DOL PI Pumps Controller","description":"\u003cp\u003eThe LC 231 pump controllers are designed for level control, monitoring and protection of Grundfos pumping systems oneÂ pumps or two pumps starting direct-on-line.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures include\u003c\/strong\u003e:\u003cbr\u003eâ€¢ Supports both empty and fill applications\u003cbr\u003eâ€¢ \u0026gt;For use with analogue (eg level transmitter) or digital sensor (eg float switch)\u003cbr\u003eâ€¢ Grundfos Go support via Bluetooth\u003cbr\u003eâ€¢ Usage, alarm and warning log\u003cbr\u003eâ€¢ BMS options (CIM module required)\u003c\/p\u003e\n\n\u003ctable class=\"spec-table\"\u003e\n  \u003ccaption\u003e\n    LC 231 1 x 1-12 DOL PI - Primary Specifications\n  \u003c\/caption\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003cth\u003eProduct Name\u003c\/th\u003e\n      \u003ctd\u003eLC 231 1 x 1-12 DOL PI\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth\u003eProduct Number\u003c\/th\u003e\n      \u003ctd\u003e99369644\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth\u003eSuitable For\u003c\/th\u003e\n      \u003ctd\u003e\n        Water treatment - Commercial buildings, Drinking water treatment,\n        Wastewater transport, Flood control, Wastewater treatment\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth\u003eNumber of Pumps\u003c\/th\u003e\n      \u003ctd\u003e1\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth\u003eMethod of Start\u003c\/th\u003e\n      \u003ctd\u003eDirect-on-line (DOL)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth\u003eRated Voltage\u003c\/th\u003e\n      \u003ctd\u003e1 x 110-240 V (3 x 200-460 V)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth\u003eRated Current\u003c\/th\u003e\n      \u003ctd\u003e1-12 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth\u003eMains Frequency\u003c\/th\u003e\n      \u003ctd\u003e50 \/ 60 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth\u003eEnclosure Class\u003c\/th\u003e\n      \u003ctd\u003eIP54\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth\u003eCabinet Material\u003c\/th\u003e\n      \u003ctd\u003ePlastic\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth\u003eAmbient Temperature Range\u003c\/th\u003e\n      \u003ctd\u003e-25 â€¦ 45 °C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth\u003eCabinet Mounting\u003c\/th\u003e\n      \u003ctd\u003eWall mounting\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth\u003eEarth Connection\u003c\/th\u003e\n      \u003ctd\u003eN, PE\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth\u003eBack-up Fuse Required\u003c\/th\u003e\n      \u003ctd\u003e16 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth\u003eCurrent Measurement\u003c\/th\u003e\n      \u003ctd\u003eYes\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth\u003eRequired Cos Phi (Full Load)\u003c\/th\u003e\n      \u003ctd\u003e0.86-1.00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth\u003eNet Weight\u003c\/th\u003e\n      \u003ctd\u003e1.78 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth\u003eGross Weight\u003c\/th\u003e\n      \u003ctd\u003e2.56 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth\u003eShipping Volume\u003c\/th\u003e\n      \u003ctd\u003e0.015 m³\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth\u003eCountry of Origin\u003c\/th\u003e\n      \u003ctd\u003eDenmark\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth\u003eApprovals\u003c\/th\u003e\n      \u003ctd\u003eCE, EAC, UKCA, MOROCCO, RCM\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cspan\u003eExplore more of our \u003ca href=\"https:\/\/pumptastic.com.au\/collections\/pump-controllers?sort_by=price-ascending\" title=\"Grundfos Pumps Controller\"\u003eGrundfos Pumps Controller\u003c\/a\u003eÂ at \u003ca title=\"Pumptastic\" href=\"https:\/\/pumptastic.com.au\/\"\u003ePumptasticÂ®\u003c\/a\u003e.\u003c\/span\u003e\u003c\/p\u003e","brand":"Grundfos","offers":[{"title":"Default Title","offer_id":42631395049581,"sku":"99369644","price":1212.98,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/PUMPS_CONTROLLER.png?v=1757573228"},{"product_id":"grundfos-lc-241-4-6-3-dol-30-150-1x230-mi-pumps-controller","title":"Grundfos LC 241 4-6,3 DOL 30 150 1x230 MI Pumps Controller","description":"\u003cp\u003eLC241 level controllers offer a comprehensive range of features for waste water pumping systems with monitoring andÂ  control of one or two pumps. The LC241 is metal cabinet solution with both indoor and outdoor versions available. Its modularity gives the flexibility required for customized solutions to match your needs.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures include\u003c\/strong\u003e:\u003cbr\u003eâ€¢ DOL and Soft Start Options\u003cbr\u003eâ€¢ Standard with Strobe and Audible alarms\u003cbr\u003eâ€¢ Support for both empty and filling applications\u003cbr\u003eâ€¢ For use with analogue level transmitters or digital float switches\u003cbr\u003eâ€¢ Easy setup wizard with Grundfos Go\u003cbr\u003eâ€¢ Alarms and Warning Logs\u003cbr\u003eâ€¢ BMS connectivity and much more\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e: 1x 220-240 V DOL\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIn [A]\u003c\/strong\u003e: 6-10\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec-table\"\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eModel\u003c\/td\u003e\n    \u003ctd\u003eLC 241 2 x 4-6,3 DOL 30 150 1X230 MI OPT\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eProduct Number\u003c\/td\u003e\n    \u003ctd\u003e99922188\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eApplication\u003c\/td\u003e\n    \u003ctd\u003eWastewater and water supply level control\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eSuitable For\u003c\/td\u003e\n    \u003ctd\u003e\n      Water treatment - Commercial buildings\u003cbr\u003e\n      Drinking water treatment\u003cbr\u003e\n      Wastewater transport\u003cbr\u003e\n      Flood control\u003cbr\u003e\n      Wastewater treatment\n    \u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eNumber of Pumps\u003c\/td\u003e\n    \u003ctd\u003e2\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eMethod of Start\u003c\/td\u003e\n    \u003ctd\u003eDirect-on-line (DOL)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eRated Voltage\u003c\/td\u003e\n    \u003ctd\u003e1 x 220-240 V\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eRated Current\u003c\/td\u003e\n    \u003ctd\u003e4-6.3 A\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eMains Frequency\u003c\/td\u003e\n    \u003ctd\u003e50 \/ 60 Hz\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eEnclosure Class\u003c\/td\u003e\n    \u003ctd\u003eIP54\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eCabinet Material\u003c\/td\u003e\n    \u003ctd\u003eMetal, painted\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eAmbient Temperature Range\u003c\/td\u003e\n    \u003ctd\u003e-5 to 40 °C\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cspan\u003eExplore more of our \u003ca href=\"https:\/\/pumptastic.com.au\/collections\/pump-controllers?sort_by=price-ascending\" title=\"Grundfos Pumps Controller\"\u003eGrundfos Pumps Controller\u003c\/a\u003eÂ at \u003ca title=\"Pumptastic\" href=\"https:\/\/pumptastic.com.au\/\"\u003ePumptasticÂ®\u003c\/a\u003e.\u003c\/span\u003e\u003c\/p\u003e","brand":"Grundfos","offers":[{"title":"Default Title","offer_id":42631422115949,"sku":"99922188","price":3604.58,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/Screenshot2025-06-30100629.png?v=1751249210"},{"product_id":"grundfos-lc-241-6-10-dol-30-150-1x230-mi-pumps-controller","title":"Grundfos LC 241 6-10 DOL 30 150 1x230 MI Pumps Controller","description":"\u003cp\u003eLC241 level controllers offer a comprehensive range of features for waste water pumping systems with monitoring andÂ  control of one or two pumps. The LC241 is metal cabinet solution with both indoor and outdoor versions available. Its modularity gives the flexibility required for customized solutions to match your needs.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures include\u003c\/strong\u003e:\u003cbr\u003eâ€¢ DOL and Soft Start Options\u003cbr\u003eâ€¢ Standard with Strobe and Audible alarms\u003cbr\u003eâ€¢ Support for both empty and filling applications\u003cbr\u003eâ€¢ For use with analogue level transmitters or digital float switches\u003cbr\u003eâ€¢ Easy setup wizard with Grundfos Go\u003cbr\u003eâ€¢ Alarms and Warning Logs\u003cbr\u003eâ€¢ BMS connectivity and much more\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e: 1x 220-240 V DOL\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIn [A]\u003c\/strong\u003e: 6-10\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec-table\"\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eModel\u003c\/td\u003e\n    \u003ctd\u003eLC 241 2 x 6-10 DOL 30 150 1X230 MI OPT\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eProduct Number\u003c\/td\u003e\n    \u003ctd\u003e99922189\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eApplication\u003c\/td\u003e\n    \u003ctd\u003eWastewater and water supply level control\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eSuitable For\u003c\/td\u003e\n    \u003ctd\u003e\n      Water treatment - Commercial buildings\u003cbr\u003e\n      Drinking water treatment\u003cbr\u003e\n      Wastewater transport\u003cbr\u003e\n      Flood control\u003cbr\u003e\n      Wastewater treatment\n    \u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eNumber of Pumps\u003c\/td\u003e\n    \u003ctd\u003e2\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eMethod of Start\u003c\/td\u003e\n    \u003ctd\u003eDirect-on-line (DOL)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eRated Voltage\u003c\/td\u003e\n    \u003ctd\u003e1 x 220-240 V\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eRated Current\u003c\/td\u003e\n    \u003ctd\u003e6-10 A\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eMains Frequency\u003c\/td\u003e\n    \u003ctd\u003e50 \/ 60 Hz\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eEnclosure Class\u003c\/td\u003e\n    \u003ctd\u003eIP54\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eCabinet Material\u003c\/td\u003e\n    \u003ctd\u003eMetal, painted\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eAmbient Temperature Range\u003c\/td\u003e\n    \u003ctd\u003e-5 to 40 °C\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cspan\u003eExplore more of our \u003ca href=\"https:\/\/pumptastic.com.au\/collections\/pump-controllers?sort_by=price-ascending\" title=\"Grundfos Pumps Controller\"\u003eGrundfos Pumps Controller\u003c\/a\u003eÂ at \u003ca title=\"Pumptastic\" href=\"https:\/\/pumptastic.com.au\/\"\u003ePumptasticÂ®\u003c\/a\u003e.\u003c\/span\u003e\u003c\/p\u003e","brand":"Grundfos","offers":[{"title":"Default Title","offer_id":42631461896301,"sku":"99922189","price":3612.98,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/Screenshot2025-06-30100629.png?v=1751249210"},{"product_id":"grundfos-lc-241-2-5-4-dol-3x400-mi-pumps-controller","title":"Grundfos LC 241 2,5-4 DOL 3x400 MI Pumps Controller","description":"\u003cp\u003eLC241 level controllers offer a comprehensive range of features for waste water pumping systems with monitoring andÂ  control of one or two pumps. The LC241 is metal cabinet solution with both indoor and outdoor versions available. Its modularity gives the flexibility required for customized solutions to match your needs.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures include\u003c\/strong\u003e:\u003cbr\u003eâ€¢ DOL and Soft Start Options\u003cbr\u003eâ€¢ Standard with Strobe and Audible alarms\u003cbr\u003eâ€¢ Support for both empty and filling applications\u003cbr\u003eâ€¢ For use with analogue level transmitters or digital float switches\u003cbr\u003eâ€¢ Easy setup wizard with Grundfos Go\u003cbr\u003eâ€¢ Alarms and Warning Logs\u003cbr\u003eâ€¢ BMS connectivity and much more\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e: 3x 220-240\/380-415 V DOL\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIn [A]\u003c\/strong\u003e: 2.5-4\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec-table\"\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eModel\u003c\/td\u003e\n    \u003ctd\u003eLC 241 2 x 2,5-4 DOL 3X230\/400 MI OPT\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eProduct Number\u003c\/td\u003e\n    \u003ctd\u003e99837575\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eApplication\u003c\/td\u003e\n    \u003ctd\u003eWastewater and water supply level control\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eSuitable For\u003c\/td\u003e\n    \u003ctd\u003e\n      Water treatment - Commercial buildings\u003cbr\u003e\n      Drinking water treatment\u003cbr\u003e\n      Wastewater transport\u003cbr\u003e\n      Flood control\u003cbr\u003e\n      Wastewater treatment\n    \u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eNumber of Pumps\u003c\/td\u003e\n    \u003ctd\u003e2\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eMethod of Start\u003c\/td\u003e\n    \u003ctd\u003eDirect-on-line (DOL)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eRated Voltage\u003c\/td\u003e\n    \u003ctd\u003e3 x 220-240 \/ 380-415 V\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eRated Current\u003c\/td\u003e\n    \u003ctd\u003e2.5-4 A\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eMains Frequency\u003c\/td\u003e\n    \u003ctd\u003e50 \/ 60 Hz\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eEnclosure Class\u003c\/td\u003e\n    \u003ctd\u003eIP54\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eCabinet Material\u003c\/td\u003e\n    \u003ctd\u003eMetal, painted\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eAmbient Temperature Range\u003c\/td\u003e\n    \u003ctd\u003e-5 to 40 °C\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cspan\u003eExplore more of our \u003ca href=\"https:\/\/pumptastic.com.au\/collections\/pump-controllers?sort_by=price-ascending\" title=\"Grundfos Pumps Controller\"\u003eGrundfos Pumps Controller\u003c\/a\u003eÂ at \u003ca title=\"Pumptastic\" href=\"https:\/\/pumptastic.com.au\/\"\u003ePumptasticÂ®\u003c\/a\u003e.\u003c\/span\u003e\u003c\/p\u003e","brand":"Grundfos","offers":[{"title":"Default Title","offer_id":42631462879341,"sku":"99837575","price":3419.85,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/Screenshot2025-06-30100629.png?v=1751249210"},{"product_id":"grundfos-lc-241-4-6-3-dol-3x400-mi-pumps-controller","title":"Grundfos LC 241 4-6,3 DOL 3x400 MI Pumps Controller","description":"\u003cp\u003eLC241 level controllers offer a comprehensive range of features for waste water pumping systems with monitoring andÂ  control of one or two pumps. The LC241 is metal cabinet solution with both indoor and outdoor versions available. Its modularity gives the flexibility required for customized solutions to match your needs.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures include\u003c\/strong\u003e:\u003cbr\u003eâ€¢ DOL and Soft Start Options\u003cbr\u003eâ€¢ Standard with Strobe and Audible alarms\u003cbr\u003eâ€¢ Support for both empty and filling applications\u003cbr\u003eâ€¢ For use with analogue level transmitters or digital float switches\u003cbr\u003eâ€¢ Easy setup wizard with Grundfos Go\u003cbr\u003eâ€¢ Alarms and Warning Logs\u003cbr\u003eâ€¢ BMS connectivity and much more\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e: 3x 220-240\/380-415 V DOL\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIn [A]\u003c\/strong\u003e: 4-6.3\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec-table\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eLevel Controller \/ Control Panel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel\u003c\/td\u003e\n      \u003ctd\u003eLC 241 2 x 4-6,3 DOL 3X230\/400 MI OPT\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Number\u003c\/td\u003e\n      \u003ctd\u003e99837576\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eApplications\u003c\/td\u003e\n      \u003ctd\u003e\n        Commercial Water Treatment, Drinking Water Treatment, Wastewater\n        Transport, Flood Control, Wastewater Treatment\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Pumps Controlled\u003c\/td\u003e\n      \u003ctd\u003e2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCabinet Material\u003c\/td\u003e\n      \u003ctd\u003eMetal, painted\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCabinet Mounting\u003c\/td\u003e\n      \u003ctd\u003eWall mounting\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAmbient Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e-5 .. 40 °C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEarth Connection\u003c\/td\u003e\n      \u003ctd\u003eN, PE\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRated Voltage\u003c\/td\u003e\n      \u003ctd\u003e3 x 220-240 \/ 380-415 V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRated Current\u003c\/td\u003e\n      \u003ctd\u003e4-6.3 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMethod of Start\u003c\/td\u003e\n      \u003ctd\u003eDirect-on-line (DOL)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMains Frequency\u003c\/td\u003e\n      \u003ctd\u003e50 \/ 60 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEnclosure Class\u003c\/td\u003e\n      \u003ctd\u003eIP54\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBack-up Fuse Required\u003c\/td\u003e\n      \u003ctd\u003e16 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eApprovals\u003c\/td\u003e\n      \u003ctd\u003eCE, RCM\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNet Weight\u003c\/td\u003e\n      \u003ctd\u003e30 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eGross Weight\u003c\/td\u003e\n      \u003ctd\u003e50 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eShipping Volume\u003c\/td\u003e\n      \u003ctd\u003e0.17 m³\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCountry of Origin\u003c\/td\u003e\n      \u003ctd\u003eCN\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCustom Tariff No.\u003c\/td\u003e\n      \u003ctd\u003e8537109019\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEAN Number\u003c\/td\u003e\n      \u003ctd\u003e5713834984600\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSales Region\u003c\/td\u003e\n      \u003ctd\u003eOCEANIA\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cspan\u003eExplore more of our \u003ca href=\"https:\/\/pumptastic.com.au\/collections\/pump-controllers?sort_by=price-ascending\" title=\"Grundfos Pumps Controller\"\u003eGrundfos Pumps Controller\u003c\/a\u003eÂ at \u003ca title=\"Pumptastic\" href=\"https:\/\/pumptastic.com.au\/\"\u003ePumptasticÂ®\u003c\/a\u003e.\u003c\/span\u003e\u003c\/p\u003e","brand":"Grundfos","offers":[{"title":"Default Title","offer_id":42631464190061,"sku":"99837576","price":3419.85,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/Screenshot2025-06-30100629.png?v=1751249210"},{"product_id":"grundfos-lc-241-6-10-dol-3x400-mi-pumps-controller","title":"Grundfos LC 241 6-10 DOL 3x400 MI Pumps Controller","description":"\u003cp\u003eLC241 level controllers offer a comprehensive range of features for waste water pumping systems with monitoring andÂ  control of one or two pumps. The LC241 is metal cabinet solution with both indoor and outdoor versions available. Its modularity gives the flexibility required for customized solutions to match your needs.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures include\u003c\/strong\u003e:\u003cbr\u003eâ€¢ DOL and Soft Start Options\u003cbr\u003eâ€¢ Standard with Strobe and Audible alarms\u003cbr\u003eâ€¢ Support for both empty and filling applications\u003cbr\u003eâ€¢ For use with analogue level transmitters or digital float switches\u003cbr\u003eâ€¢ Easy setup wizard with Grundfos Go\u003cbr\u003eâ€¢ Alarms and Warning Logs\u003cbr\u003eâ€¢ BMS connectivity and much more\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e: 3x 220-240\/380-415 V DOL\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIn [A]\u003c\/strong\u003e: 6-10\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrimary Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec-table\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003ePump Level Controller\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel\u003c\/td\u003e\n      \u003ctd\u003eLC 241 2 x 6-10 DOL 3X230\/400 MI OPT\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Number\u003c\/td\u003e\n      \u003ctd\u003e99837577\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eApplications\u003c\/td\u003e\n      \u003ctd\u003e\n        Commercial Wastewater, Drinking Water Treatment, Wastewater Transport,\n        Flood Control, Wastewater Treatment\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Pumps Controlled\u003c\/td\u003e\n      \u003ctd\u003e2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCabinet Material\u003c\/td\u003e\n      \u003ctd\u003eMetal, painted\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAmbient Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e-5 .. 40 °C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCabinet Mounting\u003c\/td\u003e\n      \u003ctd\u003eWall mounted\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEarth Connection\u003c\/td\u003e\n      \u003ctd\u003eN, PE\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRated Voltage\u003c\/td\u003e\n      \u003ctd\u003e3 x 220-240 \/ 380-415 V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRated Current\u003c\/td\u003e\n      \u003ctd\u003e6-10 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMethod of Start\u003c\/td\u003e\n      \u003ctd\u003eDirect-on-line (DOL)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEnclosure Class\u003c\/td\u003e\n      \u003ctd\u003eIP54\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBack-up Fuse Required\u003c\/td\u003e\n      \u003ctd\u003e35 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eControls\u003c\/td\u003e\n      \u003ctd\u003eMains switch: Yes, Circuit breaker per pump: Yes, Others: No\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eApprovals\u003c\/td\u003e\n      \u003ctd\u003eCE, RCM\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNet Weight\u003c\/td\u003e\n      \u003ctd\u003e30 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eGross Weight\u003c\/td\u003e\n      \u003ctd\u003e50 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eShipping Volume\u003c\/td\u003e\n      \u003ctd\u003e0.17 m³\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEAN Number\u003c\/td\u003e\n      \u003ctd\u003e5713834984617\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSales Region\u003c\/td\u003e\n      \u003ctd\u003eOCEANIA\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cspan\u003eExplore more of our \u003ca href=\"https:\/\/pumptastic.com.au\/collections\/pump-controllers?sort_by=price-ascending\" title=\"Grundfos Pumps Controller\"\u003eGrundfos Pumps Controller\u003c\/a\u003eÂ at \u003ca title=\"Pumptastic\" href=\"https:\/\/pumptastic.com.au\/\"\u003ePumptasticÂ®\u003c\/a\u003e.\u003c\/span\u003e\u003c\/p\u003e","brand":"Grundfos","offers":[{"title":"Default Title","offer_id":42631464321133,"sku":"99837577","price":3438.17,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/Screenshot2025-06-30100629.png?v=1751249210"},{"product_id":"grundfos-lc-241-9-14-dol-3x400-mi-pumps-controller","title":"Grundfos LC 241 9-14 DOL 3x400 MI Pumps Controller","description":"\u003cp\u003eLC241 level controllers offer a comprehensive range of features for waste water pumping systems with monitoring andÂ  control of one or two pumps. The LC241 is metal cabinet solution with both indoor and outdoor versions available. Its modularity gives the flexibility required for customized solutions to match your needs.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures include\u003c\/strong\u003e:\u003cbr\u003eâ€¢ DOL and Soft Start Options\u003cbr\u003eâ€¢ Standard with Strobe and Audible alarms\u003cbr\u003eâ€¢ Support for both empty and filling applications\u003cbr\u003eâ€¢ For use with analogue level transmitters or digital float switches\u003cbr\u003eâ€¢ Easy setup wizard with Grundfos Go\u003cbr\u003eâ€¢ Alarms and Warning Logs\u003cbr\u003eâ€¢ BMS connectivity and much more\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e: 3x 220-240\/380-415 V DOL\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIn [A]\u003c\/strong\u003e: 9-14\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec-table\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003ePump Level Controller\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel\u003c\/td\u003e\n      \u003ctd\u003eLC 241 2 x 9-14 DOL 3X230\/400 MI OPT\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Number\u003c\/td\u003e\n      \u003ctd\u003e99837578\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eApplications\u003c\/td\u003e\n      \u003ctd\u003e\n        Commercial Wastewater, Drinking Water Treatment, Wastewater Transport,\n        Flood Control, Wastewater Treatment\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Pumps Controlled\u003c\/td\u003e\n      \u003ctd\u003e2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCabinet Material\u003c\/td\u003e\n      \u003ctd\u003eMetal, painted\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAmbient Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e-5 .. 40 °C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCabinet Mounting\u003c\/td\u003e\n      \u003ctd\u003eWall mounted\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEarth Connection\u003c\/td\u003e\n      \u003ctd\u003eN, PE\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRated Voltage\u003c\/td\u003e\n      \u003ctd\u003e3 x 220-240 \/ 380-415 V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRated Current\u003c\/td\u003e\n      \u003ctd\u003e9-14 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMethod of Start\u003c\/td\u003e\n      \u003ctd\u003eDirect-on-line (DOL)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEnclosure Class\u003c\/td\u003e\n      \u003ctd\u003eIP54\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBack-up Fuse Required\u003c\/td\u003e\n      \u003ctd\u003e35 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eControls\u003c\/td\u003e\n      \u003ctd\u003eMains switch: Yes, Circuit breaker per pump: Yes, Others: No\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eApprovals\u003c\/td\u003e\n      \u003ctd\u003eCE, RCM\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNet Weight\u003c\/td\u003e\n      \u003ctd\u003e30 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eGross Weight\u003c\/td\u003e\n      \u003ctd\u003e50 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eShipping Volume\u003c\/td\u003e\n      \u003ctd\u003e0.17 m³\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEAN Number\u003c\/td\u003e\n      \u003ctd\u003e5713834984624\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSales Region\u003c\/td\u003e\n      \u003ctd\u003eOCEANIA\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cspan\u003eExplore more of our \u003ca href=\"https:\/\/pumptastic.com.au\/collections\/pump-controllers?sort_by=price-ascending\" title=\"Grundfos Pumps Controller\"\u003eGrundfos Pumps Controller\u003c\/a\u003eÂ at \u003ca title=\"Pumptastic\" href=\"https:\/\/pumptastic.com.au\/\"\u003ePumptasticÂ®\u003c\/a\u003e.\u003c\/span\u003e\u003c\/p\u003e","brand":"Grundfos","offers":[{"title":"Default Title","offer_id":42631464419437,"sku":"99837578","price":3502.29,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/Screenshot2025-06-30100629.png?v=1751249210"},{"product_id":"grundfos-lc-241-13-18-dol-3x400-mi-pumps-controller","title":"Grundfos LC 241 13-18 DOL 3x400 MI Pumps Controller","description":"\u003cp\u003eLC241 level controllers offer a comprehensive range of features for waste water pumping systems with monitoring andÂ  control of one or two pumps. The LC241 is metal cabinet solution with both indoor and outdoor versions available. Its modularity gives the flexibility required for customized solutions to match your needs.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures include\u003c\/strong\u003e:\u003cbr\u003eâ€¢ DOL and Soft Start Options\u003cbr\u003eâ€¢ Standard with Strobe and Audible alarms\u003cbr\u003eâ€¢ Support for both empty and filling applications\u003cbr\u003eâ€¢ For use with analogue level transmitters or digital float switches\u003cbr\u003eâ€¢ Easy setup wizard with Grundfos Go\u003cbr\u003eâ€¢ Alarms and Warning Logs\u003cbr\u003eâ€¢ BMS connectivity and much more\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e: 3x 220-240\/380-415 V DOL\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIn [A]\u003c\/strong\u003e: 13-18\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec-table\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003ePump Level Controller\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel\u003c\/td\u003e\n      \u003ctd\u003eLC 241 2 x 13-18 DOL 3X230\/400 MI OPT\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Number\u003c\/td\u003e\n      \u003ctd\u003e99837579\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eApplications\u003c\/td\u003e\n      \u003ctd\u003e\n        Commercial Wastewater, Drinking Water Treatment, Wastewater Transport,\n        Flood Control, Wastewater Treatment\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Pumps Controlled\u003c\/td\u003e\n      \u003ctd\u003e2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCabinet Material\u003c\/td\u003e\n      \u003ctd\u003eMetal, painted\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAmbient Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e-5 .. 40 °C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCabinet Mounting\u003c\/td\u003e\n      \u003ctd\u003eWall mounted\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEarth Connection\u003c\/td\u003e\n      \u003ctd\u003eN, PE\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRated Voltage\u003c\/td\u003e\n      \u003ctd\u003e3 x 220-240 \/ 380-415 V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRated Current\u003c\/td\u003e\n      \u003ctd\u003e13-18 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMethod of Start\u003c\/td\u003e\n      \u003ctd\u003eDirect-on-line (DOL)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEnclosure Class\u003c\/td\u003e\n      \u003ctd\u003eIP54\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBack-up Fuse Required\u003c\/td\u003e\n      \u003ctd\u003e50 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eControls\u003c\/td\u003e\n      \u003ctd\u003eMains switch: Yes, Circuit breaker per pump: Yes, Others: No\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eApprovals\u003c\/td\u003e\n      \u003ctd\u003eCE, RCM\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNet Weight\u003c\/td\u003e\n      \u003ctd\u003e40 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eGross Weight\u003c\/td\u003e\n      \u003ctd\u003e65 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eShipping Volume\u003c\/td\u003e\n      \u003ctd\u003e0.25 m³\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEAN Number\u003c\/td\u003e\n      \u003ctd\u003e5713834984631\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSales Region\u003c\/td\u003e\n      \u003ctd\u003eOCEANIA\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003eExplore more of our \u003ca href=\"https:\/\/pumptastic.com.au\/collections\/pump-controllers?sort_by=price-ascending\" title=\"Grundfos Pumps Controller\"\u003eGrundfos Pumps Controller\u003c\/a\u003eÂ at \u003ca title=\"Pumptastic\" href=\"https:\/\/pumptastic.com.au\/\"\u003ePumptasticÂ®\u003c\/a\u003e.\u003c\/span\u003e\u003c\/p\u003e","brand":"Grundfos","offers":[{"title":"Default Title","offer_id":42631464550509,"sku":"99837579","price":3866.41,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/Screenshot2025-06-30100629.png?v=1751249210"},{"product_id":"grundfos-lc-241-17-23-dol-3x400-mi-pumps-controller","title":"Grundfos LC 241 17-23 DOL 3x400 MI Pumps Controller","description":"\u003cp\u003eLC241 level controllers offer a comprehensive range of features for waste water pumping systems with monitoring andÂ  control of one or two pumps. The LC241 is metal cabinet solution with both indoor and outdoor versions available. Its modularity gives the flexibility required for customized solutions to match your needs.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures include\u003c\/strong\u003e:\u003cbr\u003eâ€¢ DOL and Soft Start Options\u003cbr\u003eâ€¢ Standard with Strobe and Audible alarms\u003cbr\u003eâ€¢ Support for both empty and filling applications\u003cbr\u003eâ€¢ For use with analogue level transmitters or digital float switches\u003cbr\u003eâ€¢ Easy setup wizard with Grundfos Go\u003cbr\u003eâ€¢ Alarms and Warning Logs\u003cbr\u003eâ€¢ BMS connectivity and much more\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e: 3x 220-240\/380-415 V DOL\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIn [A]\u003c\/strong\u003e: 17-23\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec-table\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003ePump Level Controller\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel\u003c\/td\u003e\n      \u003ctd\u003eLC 241 2 x 17-23 DOL 3X230\/400 MI OPT\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Number\u003c\/td\u003e\n      \u003ctd\u003e99837478\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eApplications\u003c\/td\u003e\n      \u003ctd\u003e\n        Commercial Wastewater, Drinking Water Treatment, Wastewater Transport,\n        Flood Control, Wastewater Treatment\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Pumps Controlled\u003c\/td\u003e\n      \u003ctd\u003e2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCabinet Material\u003c\/td\u003e\n      \u003ctd\u003eMetal, painted\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAmbient Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e-5 .. 40 °C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCabinet Mounting\u003c\/td\u003e\n      \u003ctd\u003eWall mounted\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEarth Connection\u003c\/td\u003e\n      \u003ctd\u003eN, PE\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRated Voltage\u003c\/td\u003e\n      \u003ctd\u003e3 x 220-240 \/ 380-415 V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRated Current\u003c\/td\u003e\n      \u003ctd\u003e17-23 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMethod of Start\u003c\/td\u003e\n      \u003ctd\u003eDirect-on-line (DOL)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEnclosure Class\u003c\/td\u003e\n      \u003ctd\u003eIP54\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBack-up Fuse Required\u003c\/td\u003e\n      \u003ctd\u003e50 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eControls\u003c\/td\u003e\n      \u003ctd\u003eMains switch: Yes, Circuit breaker per pump: Yes, Others: No\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eApprovals\u003c\/td\u003e\n      \u003ctd\u003eCE, RCM\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNet Weight\u003c\/td\u003e\n      \u003ctd\u003e40 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eGross Weight\u003c\/td\u003e\n      \u003ctd\u003e65 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eShipping Volume\u003c\/td\u003e\n      \u003ctd\u003e0.25 m³\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEAN Number\u003c\/td\u003e\n      \u003ctd\u003e5713834983603\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSales Region\u003c\/td\u003e\n      \u003ctd\u003eOCEANIA\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cspan\u003eExplore more of our \u003ca href=\"https:\/\/pumptastic.com.au\/collections\/pump-controllers?sort_by=price-ascending\" title=\"Grundfos Pumps Controller\"\u003eGrundfos Pumps Controller\u003c\/a\u003eÂ at \u003ca title=\"Pumptastic\" href=\"https:\/\/pumptastic.com.au\/\"\u003ePumptasticÂ®\u003c\/a\u003e.\u003c\/span\u003e\u003c\/p\u003e","brand":"Grundfos","offers":[{"title":"Default Title","offer_id":42631465468013,"sku":"99837478","price":3933.59,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/Screenshot2025-06-30100629.png?v=1751249210"},{"product_id":"grundfos-lc-241-10-16-sst-3x400-mi-pumps-controller","title":"Grundfos LC 241 10-16 SST 3x400 MI Pumps Controller","description":"\u003cp\u003eLC241 level controllers offer a comprehensive range of features for waste water pumping systems with monitoring andÂ  control of one or two pumps. The LC241 is metal cabinet solution with both indoor and outdoor versions available. Its modularity gives the flexibility required for customized solutions to match your needs.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures include\u003c\/strong\u003e:\u003cbr\u003eâ€¢ DOL and Soft Start Options\u003cbr\u003eâ€¢ Standard with Strobe and Audible alarms\u003cbr\u003eâ€¢ Support for both empty and filling applications\u003cbr\u003eâ€¢ For use with analogue level transmitters or digital float switches\u003cbr\u003eâ€¢ Easy setup wizard with Grundfos Go\u003cbr\u003eâ€¢ Alarms and Warning Logs\u003cbr\u003eâ€¢ BMS connectivity and much more\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e: 3x 220-240\/380-415 V SS\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIn [A]\u003c\/strong\u003e: 10-16\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003ePump Level Controller\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel\u003c\/td\u003e\n      \u003ctd\u003eLC 241 2 x 10-16 SST 3X230\/400 MI OPT\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Number\u003c\/td\u003e\n      \u003ctd\u003e99837486\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eApplications\u003c\/td\u003e\n      \u003ctd\u003e\n        Commercial Wastewater, Drinking Water Treatment, Wastewater Transport,\n        Flood Control, Wastewater Treatment\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Pumps Controlled\u003c\/td\u003e\n      \u003ctd\u003e2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCabinet Material\u003c\/td\u003e\n      \u003ctd\u003eMetal, painted\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAmbient Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e-5 .. 40 °C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCabinet Mounting\u003c\/td\u003e\n      \u003ctd\u003eWall mounted\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEarth Connection\u003c\/td\u003e\n      \u003ctd\u003eN, PE\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRated Voltage\u003c\/td\u003e\n      \u003ctd\u003e3 x 220-240 \/ 380-415 V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRated Current\u003c\/td\u003e\n      \u003ctd\u003e10-16 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMethod of Start\u003c\/td\u003e\n      \u003ctd\u003eSoft starter\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEnclosure Class\u003c\/td\u003e\n      \u003ctd\u003eIP54\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBack-up Fuse Required\u003c\/td\u003e\n      \u003ctd\u003e35 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eControls\u003c\/td\u003e\n      \u003ctd\u003eMains switch: Yes, Circuit breaker per pump: Yes, Others: No\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eApprovals\u003c\/td\u003e\n      \u003ctd\u003eCE, RCM\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNet Weight\u003c\/td\u003e\n      \u003ctd\u003e40 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eGross Weight\u003c\/td\u003e\n      \u003ctd\u003e65 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEAN Number\u003c\/td\u003e\n      \u003ctd\u003e5713834983689\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSales Region\u003c\/td\u003e\n      \u003ctd\u003eOCEANIA\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cspan\u003eExplore more of our \u003ca href=\"https:\/\/pumptastic.com.au\/collections\/pump-controllers?sort_by=price-ascending\" title=\"Grundfos Pumps Controller\"\u003eGrundfos Pumps Controller\u003c\/a\u003eÂ at \u003ca title=\"Pumptastic\" href=\"https:\/\/pumptastic.com.au\/\"\u003ePumptasticÂ®\u003c\/a\u003e.\u003c\/span\u003e\u003c\/p\u003e","brand":"Grundfos","offers":[{"title":"Default Title","offer_id":42631465893997,"sku":"99837486","price":5787.02,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/Screenshot2025-06-30100629.png?v=1751249210"},{"product_id":"grundfos-lc-241-16-20-sst-3x400-mi-pumps-controllers","title":"Grundfos LC 241 16-20 SST 3x400 MI Pumps Controllers","description":"\u003cp\u003eLC241 level controllers offer a comprehensive range of features for waste water pumping systems with monitoring andÂ  control of one or two pumps. The LC241 is metal cabinet solution with both indoor and outdoor versions available. Its modularity gives the flexibility required for customized solutions to match your needs.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures include\u003c\/strong\u003e:\u003cbr\u003eâ€¢ DOL and Soft Start Options\u003cbr\u003eâ€¢ Standard with Strobe and Audible alarms\u003cbr\u003eâ€¢ Support for both empty and filling applications\u003cbr\u003eâ€¢ For use with analogue level transmitters or digital float switches\u003cbr\u003eâ€¢ Easy setup wizard with Grundfos Go\u003cbr\u003eâ€¢ Alarms and Warning Logs\u003cbr\u003eâ€¢ BMS connectivity and much more\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e: 3x 220-240\/380-415 V SS\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIn [A]\u003c\/strong\u003e: 16-20\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec-table\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003ePump Level Controller\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel\u003c\/td\u003e\n      \u003ctd\u003eLC 241 2 x 16-20 SST 3X230\/400 MI OPT\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Number\u003c\/td\u003e\n      \u003ctd\u003e99837487\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eApplications\u003c\/td\u003e\n      \u003ctd\u003e\n        Commercial Wastewater, Drinking Water Treatment, Wastewater Transport,\n        Flood Control, Wastewater Treatment\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Pumps Controlled\u003c\/td\u003e\n      \u003ctd\u003e2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCabinet Material\u003c\/td\u003e\n      \u003ctd\u003eMetal, painted\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAmbient Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e-5 .. 40 °C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCabinet Mounting\u003c\/td\u003e\n      \u003ctd\u003eWall mounted\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEarth Connection\u003c\/td\u003e\n      \u003ctd\u003eN, PE\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRated Voltage\u003c\/td\u003e\n      \u003ctd\u003e3 x 220-240 \/ 380-415 V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRated Current\u003c\/td\u003e\n      \u003ctd\u003e16-20 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMethod of Start\u003c\/td\u003e\n      \u003ctd\u003eSoft starter\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEnclosure Class\u003c\/td\u003e\n      \u003ctd\u003eIP54\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBack-up Fuse Required\u003c\/td\u003e\n      \u003ctd\u003e50 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eControls\u003c\/td\u003e\n      \u003ctd\u003eMains switch: Yes, Circuit breaker per pump: Yes, Others: No\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eApprovals\u003c\/td\u003e\n      \u003ctd\u003eCE, RCM\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNet Weight\u003c\/td\u003e\n      \u003ctd\u003e40 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eGross Weight\u003c\/td\u003e\n      \u003ctd\u003e65 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEAN Number\u003c\/td\u003e\n      \u003ctd\u003e5713834983696\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSales Region\u003c\/td\u003e\n      \u003ctd\u003eOCEANIA\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cspan\u003eExplore more of our \u003ca title=\"Grundfos Pumps Controller\" href=\"https:\/\/pumptastic.com.au\/collections\/pump-controllers?sort_by=price-ascending\"\u003eGrundfos Pumps Controller\u003c\/a\u003eÂ at \u003ca href=\"https:\/\/pumptastic.com.au\/\" title=\"Pumptastic\"\u003ePumptasticÂ®\u003c\/a\u003e.\u003c\/span\u003e\u003c\/p\u003e","brand":"Grundfos","offers":[{"title":"Default Title","offer_id":42631468875885,"sku":"99837487","price":6116.79,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/Screenshot2025-06-30100629.png?v=1751249210"},{"product_id":"grundfos-lc-241-20-25-sst-3x400-mi-pumps-controllers","title":"Grundfos LC 241 20-25 SST 3x400 MI Pumps Controllers","description":"\u003cp\u003eLC241 level controllers offer a comprehensive range of features for waste water pumping systems with monitoring andÂ  control of one or two pumps. The LC241 is metal cabinet solution with both indoor and outdoor versions available. Its modularity gives the flexibility required for customized solutions to match your needs.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures include\u003c\/strong\u003e:\u003cbr\u003eâ€¢ DOL and Soft Start Options\u003cbr\u003eâ€¢ Standard with Strobe and Audible alarms\u003cbr\u003eâ€¢ Support for both empty and filling applications\u003cbr\u003eâ€¢ For use with analogue level transmitters or digital float switches\u003cbr\u003eâ€¢ Easy setup wizard with Grundfos Go\u003cbr\u003eâ€¢ Alarms and Warning Logs\u003cbr\u003eâ€¢ BMS connectivity and much more\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e: 3x 220-240\/380-415 V SS\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIn [A]\u003c\/strong\u003e: 20-25\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrimary Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec-table\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003ePump Level Controller\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel\u003c\/td\u003e\n      \u003ctd\u003eLC 241 2 x 20-25 SST 3X230\/400 MI OPT\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Number\u003c\/td\u003e\n      \u003ctd\u003e99837488\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eApplications\u003c\/td\u003e\n      \u003ctd\u003e\n        Commercial Wastewater, Drinking Water Treatment, Wastewater Transport,\n        Flood Control, Wastewater Treatment\n      \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Pumps Controlled\u003c\/td\u003e\n      \u003ctd\u003e2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCabinet Material\u003c\/td\u003e\n      \u003ctd\u003eMetal, painted\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAmbient Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e-5 .. 40 °C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCabinet Mounting\u003c\/td\u003e\n      \u003ctd\u003eWall mounted\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRated Voltage\u003c\/td\u003e\n      \u003ctd\u003e3 x 220-240 \/ 380-415 V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRated Current\u003c\/td\u003e\n      \u003ctd\u003e20-25 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMethod of Start\u003c\/td\u003e\n      \u003ctd\u003eSoft starter\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEnclosure Class\u003c\/td\u003e\n      \u003ctd\u003eIP54\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBack-up Fuse Required\u003c\/td\u003e\n      \u003ctd\u003e50 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eControls\u003c\/td\u003e\n      \u003ctd\u003eMains switch: Yes, Circuit breaker per pump: Yes, Others: No\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eApprovals\u003c\/td\u003e\n      \u003ctd\u003eCE, RCM\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNet Weight\u003c\/td\u003e\n      \u003ctd\u003e40 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eGross Weight\u003c\/td\u003e\n      \u003ctd\u003e65 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEAN Number\u003c\/td\u003e\n      \u003ctd\u003e5713834983702\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cspan\u003eExplore more of our \u003ca title=\"Grundfos Pumps Controller\" href=\"https:\/\/pumptastic.com.au\/collections\/pump-controllers?sort_by=price-ascending\"\u003eGrundfos Pumps Controller\u003c\/a\u003eÂ at \u003ca href=\"https:\/\/pumptastic.com.au\/\" title=\"Pumptastic\"\u003ePumptasticÂ®\u003c\/a\u003e.\u003c\/span\u003e\u003c\/p\u003e","brand":"Grundfos","offers":[{"title":"Default Title","offer_id":42631470874733,"sku":"99837488","price":6158.02,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/Screenshot2025-06-30100629.png?v=1751249210"},{"product_id":"matelec-deluxe-standard-set-point-level-alarm-plus-12651","title":"Matelec Deluxe Standard Set-Point Level Alarm Plus – FPC-12651","description":"\u003cp\u003eThe Matelec Deluxe Standard Set-Point Level Alarm Plus (Part No. 12651) is a high-level alarm control panel designed for reliable monitoring of water storage tanks. It provides audible and visual alarm indication with a built-in strobe light that continues flashing even after the buzzer auto-silences until the alarm condition is cleared. Built in an IP54-rated enclosure, it supports both float switch and conductivity probe inputs and is suitable for flexible installation in domestic, commercial, and industrial water systems.\u003c\/p\u003e\n\u003ch3\u003eSuitable Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWater storage tank high\/low level monitoring\u003c\/li\u003e\n\u003cli\u003eDomestic and commercial water systems\u003c\/li\u003e\n\u003cli\u003ePump protection and dry-run prevention\u003c\/li\u003e\n\u003cli\u003eIndustrial and process water level con\u003cimg\u003etrol\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Name\u003c\/td\u003e\n\u003ctd\u003eDeluxe Standard Set-Point Level Alarm Plus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Number\u003c\/td\u003e\n\u003ctd\u003e12651\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump Type\u003c\/td\u003e\n\u003ctd\u003eLevel Alarm Panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e230Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Class\u003c\/td\u003e\n\u003ctd\u003eIP54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"Default Title","offer_id":45137691082861,"sku":"FPC-12651","price":396.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/DeluxeHighlevelalarm_1.jpg?v=1777015995"},{"product_id":"matelec-basic-high-level-alarm-level-alarm-panel-12650","title":"Matelec Basic High Level Alarm Level Alarm Panel – FPC-12650","description":"\u003cp\u003e\n  The Matelec Basic High Level Alarm (Part No. 12650) is a set-point alarm panel designed to provide reliable audible warning for water storage tank level conditions without the need for a float switch. It accepts either a 12Vdc switched control input or conductivity probe signals and triggers a buzzer alarm when activated. Housed in a robust IP54-rated polycarbonate enclosure, it features a keypad interface with status indicators, alarm mute\/reset controls, and built-in protection through low-voltage control circuitry.\n\u003c\/p\u003e\n\n\u003ch3\u003eSuitable Applications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eWater storage tank high or low level alarm monitoring\u003c\/li\u003e\n  \u003cli\u003ePump protection and dry-run warning systems\u003c\/li\u003e\n  \u003cli\u003eDomestic and commercial water level control systems\u003c\/li\u003e\n  \u003cli\u003eIndustrial liquid level alarm applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eProduct Name\u003c\/td\u003e\n    \u003ctd\u003eBasic High Level Alarm\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eProduct Number\u003c\/td\u003e\n    \u003ctd\u003e12650\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003ePump Type\u003c\/td\u003e\n    \u003ctd\u003eLevel Alarm Panel\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eVoltage\u003c\/td\u003e\n    \u003ctd\u003e230Vac\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eEnclosure\u003c\/td\u003e\n    \u003ctd\u003eIP54 Polycarbonate\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eInputs\u003c\/td\u003e\n    \u003ctd\u003e12Vdc digital input \/ conductivity probes\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eOutputs\u003c\/td\u003e\n    \u003ctd\u003eBMS Volt-free (NO \u0026amp; NC)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eIncluded Accessories\u003c\/td\u003e\n    \u003ctd\u003e10 Amp 3-pin 1m power supply lead\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"Default Title","offer_id":45137751179373,"sku":"FPC-12650","price":297.44,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/BasicHighlevelalarm.jpg?v=1777017598"},{"product_id":"standard-under-sink-sullage-alarm-with-valve-shutoff-fpc-12659","title":"Standard Under Sink\/Sullage Alarm with Valve Shutoff - FPC-12659","description":"\u003cp\u003eThe Standard Under Sink\/Sullage Alarm with Valve Shutoff monitors the level in an under sink sullage tank and in the event that the tank level goes full, possibly due to pump failure, the control will shut the mains water supply valve and give an alarm signal.\u003c\/p\u003e\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003ch4\u003eEnclosure\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIP54 rated, polycarbonate enclosure with mounting brackets\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProtection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eLow voltage control and input circuitry\u003c\/li\u003e\n\u003cli\u003ePre-wired connections - no hard wiring needed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eAudible (buzzer) alarm\u003c\/li\u003e\n\u003cli\u003eLevel alarm keypad interface, with:\n\u003cul\u003e\n\u003cli\u003eIndicator lights for power on and level alarm\u003c\/li\u003e\n\u003cli\u003eAudible alarm mute\/reset\/test button\u003c\/li\u003e\n\u003cli\u003eShut-off controller PCB control module\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSingle phase (230Vac) power supply\u003c\/li\u003e\n\u003cli\u003eDigital 12Vdc input for float switch\u003c\/li\u003e\n\u003cli\u003eProprietary 'install from the outside of the tank finger float' with 10m lead included\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOutputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e12Vdc output for solenoid valve\u003c\/li\u003e\n\u003cli\u003eBMS volt-free output for common fault\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eIncluded with Panel\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e10 Amp 3 pin 1.5m power supply lead\u003c\/li\u003e\n\u003cli\u003eMagnetic float switch with 10m cable\u003c\/li\u003e\n\u003cli\u003e20mm male\/male 12Vdc pulse latching solenoid valve\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Datasheet\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/1e6c59c34289a6cac05dbf17d2c87c7d884aa0c3.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"Default Title","offer_id":45504726564973,"sku":"FPC-12659","price":1026.96,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPC-12659-product.webp?v=1784968880"},{"product_id":"standard-under-sink-sullage-alarm-with-valve-shutoff-fpc-12660","title":"Standard Under Sink\/Sullage Alarm with Valve Shutoff - FPC-12660","description":"\u003cp\u003eThe Under Sink\/Sullage Alarm and Dishwasher Interlock has been specifically designed to monitor the level in an under sink sullage tank. If it detects the tank level full, possibly due to pump failure, the control will shut the mains supply to the Dishwasher in the system, ensuring no further water can enter the sullage tank.\u003c\/p\u003e\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003ch4\u003eEnclosure\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIP54 rated, polycarbonate enclosure with mounting brackets\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProtection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eLow voltage control and input circuitry\u003c\/li\u003e\n\u003cli\u003ePre-wired connections - no hard wiring needed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eAudible (buzzer) alarm\u003c\/li\u003e\n\u003cli\u003eLevel alarm keypad interface, with:\n\u003cul\u003e\n\u003cli\u003eIndicator lights for power on and level alarm\u003c\/li\u003e\n\u003cli\u003eAudible alarm mute\/reset\/test button\u003c\/li\u003e\n\u003cli\u003eShut-off controller PCB control module\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSingle phase (230Vac) power supply\u003c\/li\u003e\n\u003cli\u003eDigital 12Vdc input for float switch\u003c\/li\u003e\n\u003cli\u003eProprietary 'install from the outside of the tank finger float' with 10m lead included\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOutputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e10 Amp GPOs for supply to dishwasher\u003c\/li\u003e\n\u003cli\u003eBMS volt-free output for common fault\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eIncluded with Panel\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e10 Amp 3 pin 1.5m power supply lead\u003c\/li\u003e\n\u003cli\u003eMagnetic float switch with 10m cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Datasheet\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/0ef9fce5c1b2b87ba273f9e49d7815a9579351f2.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"Default Title","offer_id":45504736690285,"sku":"FPC-12660","price":923.12,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPC-12660-product.webp?v=1784969220"},{"product_id":"hydrowhiz-submersible-level-controller-1ph-1-pump-fpc-63141-aa-d","title":"HydroWHIZ Submersible Level Controller (1PH 1 Pump) - FPC-63141-(AA-D)","description":"\u003cp\u003eMATelec Australia's HydroWHIZ Controller has been designed with ease of use at the core of the system design. Building on the wealth of the pump control features in the Advanced controller, the HydroWHIZ brings these features into a new age with a colour touch screen interface and a streamlined setup process. In a world where information is power the HydroWHIZ has extensive time and date stamped alarms, logged data, trend graphs and diagnostic pages to provide the user with all the information required for optimisation and preventative maintenance. Featuring the flexibility of level, pressure and temperature system modes with a wide range of functions and protections, the HydroWHIZ controller is ideal for a vast range of applications including water transfer, stormwater and sewage pump out, pressure boosting, hot water circulation and chiller supply, to name a few.\u003c\/p\u003e\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003ch4\u003eEnclosure\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIP56 rated, powder coated mild steel enclosure with inner door and removable gland plate\u003c\/li\u003e\n\u003cli\u003eEnclosure size: 400x400x250mm+\u003c\/li\u003e\n\u003cli\u003eEnclosure size will increase for high overload ratings and optional additions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProtection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003ePad-lockable mains power isolator switch\u003c\/li\u003e\n\u003cli\u003eCircuit breaker protected low voltage control and input circuitry\u003c\/li\u003e\n\u003cli\u003eIndividual pump isolation\u003c\/li\u003e\n\u003cli\u003eContactor and thermal overload protection of pump motors\u003c\/li\u003e\n\u003cli\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHydroWHIZ colour touch screen HMI (see interface features)\u003c\/li\u003e\n\u003cli\u003eHydroWHIZ PCB control module\u003c\/li\u003e\n\u003cli\u003eVisual (strobe) and mutable audible (buzzer) alarms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSingle phase (230Vac) power supply\u003c\/li\u003e\n\u003cli\u003eAnalog 4-20mA input for level, pressure or temperature transducer\u003c\/li\u003e\n\u003cli\u003eUp to 8x digital 24Vdc inputs for low, stop, start, standby start and high float switches, pressure switches or thermostats, system enable\/disable input and a low flow switch\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOutputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e1 pump output\u003c\/li\u003e\n\u003cli\u003eBMS volt-free output for common fault\u003c\/li\u003e\n\u003cli\u003eAnalog 0-10V output (mirrors analog input)\u003c\/li\u003e\n\u003cli\u003eOutput for solenoid valve available on request\u003c\/li\u003e\n\u003cli\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommon Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWater transfer\u003c\/li\u003e\n\u003cli\u003eTank fill\u003c\/li\u003e\n\u003cli\u003eSewage pump out\u003c\/li\u003e\n\u003cli\u003eStormwater pump out\u003c\/li\u003e\n\u003cli\u003ePressure boosting\u003c\/li\u003e\n\u003cli\u003eHot water recirculation\u003c\/li\u003e\n\u003cli\u003eChiller supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/e54d9eba0e4ab3257a8d93c1c52aaa5a00c4f088.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/0fde2ce949a2d88c6cf6a1fee529c31b7451011f.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation Manual\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/fdc519f87300ef0ff4be440566ef9e32807e6c39.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuick Start Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/c13fbd566a0336d45cfecb1d3ad611f50101893b.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"-AA (1.6-2.5 Amp)","offer_id":45591606263917,"sku":"FPC-63141-AA","price":2823.92,"currency_code":"AUD","in_stock":true},{"title":"-A (2.5-4 Amp)","offer_id":45591606657133,"sku":"FPC-63141-A","price":2823.92,"currency_code":"AUD","in_stock":true},{"title":"-B (4-6 Amp)","offer_id":45591607050349,"sku":"FPC-63141-B","price":2823.92,"currency_code":"AUD","in_stock":true},{"title":"-BB (5.5-8 Amp)","offer_id":45591607443565,"sku":"FPC-63141-BB","price":2823.92,"currency_code":"AUD","in_stock":true},{"title":"-C (7-10 Amp)","offer_id":45591607836781,"sku":"FPC-63141-C","price":2823.92,"currency_code":"AUD","in_stock":true},{"title":"-D (9-13 Amp)","offer_id":45591608229997,"sku":"FPC-63141-D","price":2823.92,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPC-63141-product.webp?v=1785388512"},{"product_id":"hydrowhiz-submersible-level-controller-3ph-1-pump-fpc-63143-aa-d","title":"HydroWHIZ Submersible Level Controller (3PH 1 Pump) - FPC-63143-(AA-D)","description":"\u003cp bis_size='{\"x\":12,\"y\":9,\"w\":560,\"h\":195,\"abs_x\":618,\"abs_y\":270}'\u003eMATelec Australia's HydroWHIZ Controller has been designed with ease of use at the core of the system design. Building on the wealth of the pump control features in the Advanced controller, the HydroWHIZ brings these features into a new age with a colour touch screen interface and a streamlined setup process. In a world where information is power the HydroWHIZ has extensive time and date stamped alarms, logged data, trend graphs and diagnostic pages to provide the user with all the information required for optimisation and preventative maintenance. Featuring the flexibility of level, pressure and temperature system modes with a wide range of functions and protections, the HydroWHIZ controller is ideal for a vast range of applications including water transfer, stormwater and sewage pump out, pressure boosting, hot water circulation and chiller supply, to name a few.\u003c\/p\u003e\n\u003ch3 bis_size='{\"x\":12,\"y\":221,\"w\":560,\"h\":22,\"abs_x\":618,\"abs_y\":482}'\u003eProduct Details\u003c\/h3\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":255,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":516}'\u003eEnclosure\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":288,\"w\":560,\"h\":58,\"abs_x\":618,\"abs_y\":549}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":288,\"w\":520,\"h\":39,\"abs_x\":658,\"abs_y\":549}'\u003eIP56 rated, powder coated mild steel enclosure with inner door and removable gland plate\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":327,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":588}'\u003eEnclosure size: 400x400x250mm+\u003c\/li\u003e\n\u003cli\u003eEnclosure size will increase for high overload ratings and optional additions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":361,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":622}'\u003eProtection\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":394,\"w\":560,\"h\":97,\"abs_x\":618,\"abs_y\":655}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":394,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":655}'\u003ePad-lockable mains power isolator switch\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":414,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":675}'\u003eCircuit breaker protected low voltage control and input circuitry\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":434,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":695}'\u003eIndividual pump isolation\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":453,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":714}'\u003eContactor and thermal overload protection of pump motors\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":473,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":734}'\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":506,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":767}'\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":540,\"w\":560,\"h\":58,\"abs_x\":618,\"abs_y\":801}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":540,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":801}'\u003eHydroWHIZ colour touch screen HMI (see interface features)\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":560,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":821}'\u003eHydroWHIZ PCB control module\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":579,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":840}'\u003eVisual (strobe) and mutable audible (buzzer) alarms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":613,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":874}'\u003eInputs\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":646,\"w\":560,\"h\":117,\"abs_x\":618,\"abs_y\":907}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":646,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":907}'\u003eThree phase (400Vac) power supply\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":666,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":927}'\u003eAnalog 4-20mA input for level, pressure or temperature transducer\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":686,\"w\":520,\"h\":58,\"abs_x\":658,\"abs_y\":947}'\u003eUp to 8x digital 24Vdc inputs for low, stop, start, standby start and high float switches, pressure switches or thermostats, system enable\/disable input and a low flow switch\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":744,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1005}'\u003eThermal switch inputs per pump (three phase only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":778,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":1039}'\u003eOutputs\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":812,\"w\":560,\"h\":97,\"abs_x\":618,\"abs_y\":1073}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":812,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1073}'\u003e1 pump output\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":831,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1092}'\u003eBMS volt-free output for common fault\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":851,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1112}'\u003eAnalog 0-10V output (mirrors analog input)\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":870,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1131}'\u003eOutput for solenoid valve available on request\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":890,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1151}'\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 bis_size='{\"x\":12,\"y\":924,\"w\":560,\"h\":22,\"abs_x\":618,\"abs_y\":1185}'\u003eCommon Applications\u003c\/h3\u003e\n\u003cul bis_size='{\"x\":12,\"y\":960,\"w\":560,\"h\":137,\"abs_x\":618,\"abs_y\":1221}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":960,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1221}'\u003eWater transfer\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":980,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1241}'\u003eTank fill\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1000,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1261}'\u003eSewage pump out\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1019,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1280}'\u003eStormwater pump out\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1039,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1300}'\u003ePressure boosting\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1058,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1319}'\u003eHot water recirculation\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1078,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1339}'\u003eChiller supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 bis_size='{\"x\":12,\"y\":1112,\"w\":560,\"h\":22,\"abs_x\":618,\"abs_y\":1373}'\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\" bis_size='{\"x\":12,\"y\":1145,\"w\":560,\"h\":106,\"abs_x\":618,\"abs_y\":1406}'\u003e\n\u003ctbody bis_size='{\"x\":15,\"y\":1148,\"w\":554,\"h\":100,\"abs_x\":621,\"abs_y\":1409}'\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":1148,\"w\":554,\"h\":23,\"abs_x\":621,\"abs_y\":1409}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":1148,\"w\":358,\"h\":23,\"abs_x\":621,\"abs_y\":1409}'\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":375,\"y\":1148,\"w\":193,\"h\":23,\"abs_x\":981,\"abs_y\":1409}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/e54d9eba0e4ab3257a8d93c1c52aaa5a00c4f088.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":377,\"y\":1150,\"w\":63,\"h\":19,\"abs_x\":983,\"abs_y\":1411}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":1174,\"w\":554,\"h\":23,\"abs_x\":621,\"abs_y\":1435}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":1174,\"w\":358,\"h\":23,\"abs_x\":621,\"abs_y\":1435}'\u003eProduct Guide\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":375,\"y\":1174,\"w\":193,\"h\":23,\"abs_x\":981,\"abs_y\":1435}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/0fde2ce949a2d88c6cf6a1fee529c31b7451011f.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":377,\"y\":1176,\"w\":63,\"h\":19,\"abs_x\":983,\"abs_y\":1437}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":1199,\"w\":554,\"h\":23,\"abs_x\":621,\"abs_y\":1460}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":1199,\"w\":358,\"h\":23,\"abs_x\":621,\"abs_y\":1460}'\u003eOperation Manual\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":375,\"y\":1199,\"w\":193,\"h\":23,\"abs_x\":981,\"abs_y\":1460}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/fdc519f87300ef0ff4be440566ef9e32807e6c39.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":377,\"y\":1201,\"w\":63,\"h\":19,\"abs_x\":983,\"abs_y\":1462}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":1225,\"w\":554,\"h\":23,\"abs_x\":621,\"abs_y\":1486}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":1225,\"w\":358,\"h\":23,\"abs_x\":621,\"abs_y\":1486}'\u003eQuick Start Guide\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":375,\"y\":1225,\"w\":193,\"h\":23,\"abs_x\":981,\"abs_y\":1486}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/c13fbd566a0336d45cfecb1d3ad611f50101893b.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":377,\"y\":1227,\"w\":63,\"h\":19,\"abs_x\":983,\"abs_y\":1488}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"-AA (1.6-2.5 Amp)","offer_id":45591612096621,"sku":"FPC-63143-AA","price":2884.64,"currency_code":"AUD","in_stock":true},{"title":"-A (2.5-4 Amp)","offer_id":45591612489837,"sku":"FPC-63143-A","price":2884.64,"currency_code":"AUD","in_stock":true},{"title":"-B (4-6 Amp)","offer_id":45591612883053,"sku":"FPC-63143-B","price":2884.64,"currency_code":"AUD","in_stock":true},{"title":"-BB (5.5-8 Amp)","offer_id":45591613276269,"sku":"FPC-63143-BB","price":2884.64,"currency_code":"AUD","in_stock":true},{"title":"-C (7-10 Amp)","offer_id":45591613669485,"sku":"FPC-63143-C","price":2884.64,"currency_code":"AUD","in_stock":true},{"title":"-D (9-13 Amp)","offer_id":45591614062701,"sku":"FPC-63143-D","price":2884.64,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPC-63143-product.webp?v=1785393097"},{"product_id":"hydrowhiz-submersible-level-controller-2ph-1-pump-fpc-63141-aa-d","title":"HydroWHIZ Submersible Level Controller (1PH 2 Pump) - FPC-63241-(AA-D)","description":"\u003cp\u003eMATelec Australia's HydroWHIZ Controller has been designed with ease of use at the core of the system design. Building on the wealth of the pump control features in the Advanced controller, the HydroWHIZ brings these features into a new age with a colour touch screen interface and a streamlined setup process. In a world where information is power the HydroWHIZ has extensive time and date stamped alarms, logged data, trend graphs and diagnostic pages to provide the user with all the information required for optimisation and preventative maintenance. Featuring the flexibility of level, pressure and temperature system modes with a wide range of functions and protections, the HydroWHIZ controller is ideal for a vast range of applications including water transfer, stormwater and sewage pump out, pressure boosting, hot water circulation and chiller supply, to name a few.\u003c\/p\u003e\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003ch4\u003eEnclosure\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIP56 rated, powder coated mild steel enclosure with inner door and removable gland plate\u003c\/li\u003e\n\u003cli\u003eEnclosure size: 400x400x250mm+\u003c\/li\u003e\n\u003cli\u003eEnclosure size will increase for high overload ratings and optional additions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProtection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003ePad-lockable mains power isolator switch\u003c\/li\u003e\n\u003cli\u003eCircuit breaker protected low voltage control and input circuitry\u003c\/li\u003e\n\u003cli\u003eIndividual pump isolation\u003c\/li\u003e\n\u003cli\u003eContactor and thermal overload protection of pump motors\u003c\/li\u003e\n\u003cli\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHydroWHIZ colour touch screen HMI (see interface features)\u003c\/li\u003e\n\u003cli\u003eHydroWHIZ PCB control module\u003c\/li\u003e\n\u003cli\u003eVisual (strobe) and mutable audible (buzzer) alarms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSingle phase (230Vac) power supply\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eAnalog 4-20mA input for level, pressure or temperature transducer\u003c\/li\u003e\n\u003cli\u003eUp to 8x digital 24Vdc inputs for low, stop, start, standby start and high float switches, pressure switches or thermostats, system enable\/disable input and a low flow switch\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOutputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e2 pump output\u003c\/li\u003e\n\u003cli\u003eBMS volt-free output for common fault\u003c\/li\u003e\n\u003cli\u003eAnalog 0-10V output (mirrors analog input)\u003c\/li\u003e\n\u003cli\u003eOutput for solenoid valve available on request\u003c\/li\u003e\n\u003cli\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommon Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWater transfer\u003c\/li\u003e\n\u003cli\u003eTank fill\u003c\/li\u003e\n\u003cli\u003eSewage pump out\u003c\/li\u003e\n\u003cli\u003eStormwater pump out\u003c\/li\u003e\n\u003cli\u003ePressure boosting\u003c\/li\u003e\n\u003cli\u003eHot water recirculation\u003c\/li\u003e\n\u003cli\u003eChiller supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/e54d9eba0e4ab3257a8d93c1c52aaa5a00c4f088.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/0fde2ce949a2d88c6cf6a1fee529c31b7451011f.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation Manual\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/fdc519f87300ef0ff4be440566ef9e32807e6c39.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuick Start Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/c13fbd566a0336d45cfecb1d3ad611f50101893b.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"-AA (1.6-2.5 Amp)","offer_id":45591610622061,"sku":"FPC-63241-AA","price":3037.76,"currency_code":"AUD","in_stock":true},{"title":"-A (2.5-4 Amp)","offer_id":45591610654829,"sku":"FPC-63241-A","price":3037.76,"currency_code":"AUD","in_stock":true},{"title":"-B (4-6 Amp)","offer_id":45591610687597,"sku":"FPC-63241-B","price":3037.76,"currency_code":"AUD","in_stock":true},{"title":"-BB (5.5-8 Amp)","offer_id":45591610720365,"sku":"FPC-63241-BB","price":3037.76,"currency_code":"AUD","in_stock":true},{"title":"-C (7-10 Amp)","offer_id":45591610753133,"sku":"FPC-63241-C","price":3037.76,"currency_code":"AUD","in_stock":true},{"title":"-D (9-13 Amp)","offer_id":45591610785901,"sku":"FPC-63241-D","price":3037.76,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPC-63241-product.webp?v=1785394900"},{"product_id":"hydrowhiz-submersible-level-controller-3ph-2-pump-fpc-63243-aa-d","title":"HydroWHIZ Submersible Level Controller (3PH 2 Pump) - FPC-63243-(AA-D)","description":"\u003cp bis_size='{\"x\":12,\"y\":9,\"w\":560,\"h\":195,\"abs_x\":618,\"abs_y\":270}'\u003eMATelec Australia's HydroWHIZ Controller has been designed with ease of use at the core of the system design. Building on the wealth of the pump control features in the Advanced controller, the HydroWHIZ brings these features into a new age with a colour touch screen interface and a streamlined setup process. In a world where information is power the HydroWHIZ has extensive time and date stamped alarms, logged data, trend graphs and diagnostic pages to provide the user with all the information required for optimisation and preventative maintenance. Featuring the flexibility of level, pressure and temperature system modes with a wide range of functions and protections, the HydroWHIZ controller is ideal for a vast range of applications including water transfer, stormwater and sewage pump out, pressure boosting, hot water circulation and chiller supply, to name a few.\u003c\/p\u003e\n\u003ch3 bis_size='{\"x\":12,\"y\":221,\"w\":560,\"h\":22,\"abs_x\":618,\"abs_y\":482}'\u003eProduct Details\u003c\/h3\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":255,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":516}'\u003eEnclosure\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":288,\"w\":560,\"h\":58,\"abs_x\":618,\"abs_y\":549}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":288,\"w\":520,\"h\":39,\"abs_x\":658,\"abs_y\":549}'\u003eIP56 rated, powder coated mild steel enclosure with inner door and removable gland plate\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":327,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":588}'\u003eEnclosure size: 400x400x250mm+\u003c\/li\u003e\n\u003cli\u003eEnclosure size will increase for high overload ratings and optional additions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":361,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":622}'\u003eProtection\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":394,\"w\":560,\"h\":97,\"abs_x\":618,\"abs_y\":655}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":394,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":655}'\u003ePad-lockable mains power isolator switch\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":414,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":675}'\u003eCircuit breaker protected low voltage control and input circuitry\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":434,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":695}'\u003eIndividual pump isolation\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":453,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":714}'\u003eContactor and thermal overload protection of pump motors\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":473,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":734}'\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":506,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":767}'\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":540,\"w\":560,\"h\":58,\"abs_x\":618,\"abs_y\":801}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":540,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":801}'\u003eHydroWHIZ colour touch screen HMI (see interface features)\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":560,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":821}'\u003eHydroWHIZ PCB control module\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":579,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":840}'\u003eVisual (strobe) and mutable audible (buzzer) alarms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":613,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":874}'\u003eInputs\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":646,\"w\":560,\"h\":117,\"abs_x\":618,\"abs_y\":907}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":646,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":907}'\u003eThree phase (400Vac) power supply\u003cbr bis_size='{\"x\":270,\"y\":646,\"w\":0,\"h\":19,\"abs_x\":876,\"abs_y\":907}'\u003e\n\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":666,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":927}'\u003eAnalog 4-20mA input for level, pressure or temperature transducer\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":686,\"w\":520,\"h\":58,\"abs_x\":658,\"abs_y\":947}'\u003eUp to 8x digital 24Vdc inputs for low, stop, start, standby start and high float switches, pressure switches or thermostats, system enable\/disable input and a low flow switch\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":744,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1005}'\u003eThermal switch inputs per pump (three phase only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":778,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":1039}'\u003eOutputs\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":812,\"w\":560,\"h\":97,\"abs_x\":618,\"abs_y\":1073}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":812,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1073}'\u003e2 pump output\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":831,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1092}'\u003eBMS volt-free output for common fault\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":851,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1112}'\u003eAnalog 0-10V output (mirrors analog input)\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":870,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1131}'\u003eOutput for solenoid valve available on request\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":890,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1151}'\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 bis_size='{\"x\":12,\"y\":924,\"w\":560,\"h\":22,\"abs_x\":618,\"abs_y\":1185}'\u003eCommon Applications\u003c\/h3\u003e\n\u003cul bis_size='{\"x\":12,\"y\":960,\"w\":560,\"h\":137,\"abs_x\":618,\"abs_y\":1221}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":960,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1221}'\u003eWater transfer\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":980,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1241}'\u003eTank fill\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1000,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1261}'\u003eSewage pump out\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1019,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1280}'\u003eStormwater pump out\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1039,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1300}'\u003ePressure boosting\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1058,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1319}'\u003eHot water recirculation\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1078,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1339}'\u003eChiller supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 bis_size='{\"x\":12,\"y\":1112,\"w\":560,\"h\":22,\"abs_x\":618,\"abs_y\":1373}'\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\" bis_size='{\"x\":12,\"y\":1145,\"w\":560,\"h\":106,\"abs_x\":618,\"abs_y\":1406}'\u003e\n\u003ctbody bis_size='{\"x\":15,\"y\":1148,\"w\":554,\"h\":100,\"abs_x\":621,\"abs_y\":1409}'\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":1148,\"w\":554,\"h\":23,\"abs_x\":621,\"abs_y\":1409}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":1148,\"w\":358,\"h\":23,\"abs_x\":621,\"abs_y\":1409}'\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":375,\"y\":1148,\"w\":193,\"h\":23,\"abs_x\":981,\"abs_y\":1409}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/e54d9eba0e4ab3257a8d93c1c52aaa5a00c4f088.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":377,\"y\":1150,\"w\":63,\"h\":19,\"abs_x\":983,\"abs_y\":1411}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":1174,\"w\":554,\"h\":23,\"abs_x\":621,\"abs_y\":1435}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":1174,\"w\":358,\"h\":23,\"abs_x\":621,\"abs_y\":1435}'\u003eProduct Guide\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":375,\"y\":1174,\"w\":193,\"h\":23,\"abs_x\":981,\"abs_y\":1435}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/0fde2ce949a2d88c6cf6a1fee529c31b7451011f.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":377,\"y\":1176,\"w\":63,\"h\":19,\"abs_x\":983,\"abs_y\":1437}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":1199,\"w\":554,\"h\":23,\"abs_x\":621,\"abs_y\":1460}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":1199,\"w\":358,\"h\":23,\"abs_x\":621,\"abs_y\":1460}'\u003eOperation Manual\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":375,\"y\":1199,\"w\":193,\"h\":23,\"abs_x\":981,\"abs_y\":1460}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/fdc519f87300ef0ff4be440566ef9e32807e6c39.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":377,\"y\":1201,\"w\":63,\"h\":19,\"abs_x\":983,\"abs_y\":1462}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":1225,\"w\":554,\"h\":23,\"abs_x\":621,\"abs_y\":1486}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":1225,\"w\":358,\"h\":23,\"abs_x\":621,\"abs_y\":1486}'\u003eQuick Start Guide\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":375,\"y\":1225,\"w\":193,\"h\":23,\"abs_x\":981,\"abs_y\":1486}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/c13fbd566a0336d45cfecb1d3ad611f50101893b.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":377,\"y\":1227,\"w\":63,\"h\":19,\"abs_x\":983,\"abs_y\":1488}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"-AA (1.6-2.5 Amp)","offer_id":45591624548461,"sku":"FPC-63243-AA","price":3120.48,"currency_code":"AUD","in_stock":true},{"title":"-A (2.5-4 Amp)","offer_id":45591624941677,"sku":"FPC-63243-A","price":3120.48,"currency_code":"AUD","in_stock":true},{"title":"-B (4-6 Amp)","offer_id":45591625334893,"sku":"FPC-63243-B","price":3120.48,"currency_code":"AUD","in_stock":true},{"title":"-BB (5.5-8 Amp)","offer_id":45591625728109,"sku":"FPC-63243-BB","price":3120.48,"currency_code":"AUD","in_stock":true},{"title":"-C (7-10 Amp)","offer_id":45591626121325,"sku":"FPC-63243-C","price":3120.48,"currency_code":"AUD","in_stock":true},{"title":"-D (9-13 Amp)","offer_id":45591626514541,"sku":"FPC-63243-D","price":3120.48,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPC-63243-product.webp?v=1785395454"},{"product_id":"hydrowhiz-submersible-level-controller-1ph-3-pump-fpc-63341-aa-d","title":"HydroWHIZ Submersible Level Controller (1PH 3 Pump) - FPC-63341-(AA-D)","description":"\u003cp bis_size='{\"x\":12,\"y\":9,\"w\":560,\"h\":195,\"abs_x\":618,\"abs_y\":270}'\u003eMATelec Australia's HydroWHIZ Controller has been designed with ease of use at the core of the system design. Building on the wealth of the pump control features in the Advanced controller, the HydroWHIZ brings these features into a new age with a colour touch screen interface and a streamlined setup process. In a world where information is power the HydroWHIZ has extensive time and date stamped alarms, logged data, trend graphs and diagnostic pages to provide the user with all the information required for optimisation and preventative maintenance. Featuring the flexibility of level, pressure and temperature system modes with a wide range of functions and protections, the HydroWHIZ controller is ideal for a vast range of applications including water transfer, stormwater and sewage pump out, pressure boosting, hot water circulation and chiller supply, to name a few.\u003c\/p\u003e\n\u003ch3 bis_size='{\"x\":12,\"y\":221,\"w\":560,\"h\":22,\"abs_x\":618,\"abs_y\":482}'\u003eProduct Details\u003c\/h3\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":255,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":516}'\u003eEnclosure\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":288,\"w\":560,\"h\":58,\"abs_x\":618,\"abs_y\":549}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":288,\"w\":520,\"h\":39,\"abs_x\":658,\"abs_y\":549}'\u003eIP56 rated, powder coated mild steel enclosure with inner door and removable gland plate\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":327,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":588}'\u003eEnclosure size: 400x400x250mm+\u003c\/li\u003e\n\u003cli\u003eEnclosure size will increase for high overload ratings and optional additions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":361,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":622}'\u003eProtection\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":394,\"w\":560,\"h\":97,\"abs_x\":618,\"abs_y\":655}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":394,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":655}'\u003ePad-lockable mains power isolator switch\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":414,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":675}'\u003eCircuit breaker protected low voltage control and input circuitry\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":434,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":695}'\u003eIndividual pump isolation\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":453,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":714}'\u003eContactor and thermal overload protection of pump motors\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":473,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":734}'\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":506,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":767}'\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":540,\"w\":560,\"h\":58,\"abs_x\":618,\"abs_y\":801}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":540,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":801}'\u003eHydroWHIZ colour touch screen HMI (see interface features)\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":560,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":821}'\u003eHydroWHIZ PCB control module\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":579,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":840}'\u003eVisual (strobe) and mutable audible (buzzer) alarms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":613,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":874}'\u003eInputs\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":646,\"w\":560,\"h\":97,\"abs_x\":618,\"abs_y\":907}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":646,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":907}'\u003eSingle phase (230Vac) power supply\u003cbr bis_size='{\"x\":273,\"y\":646,\"w\":0,\"h\":19,\"abs_x\":879,\"abs_y\":907}'\u003e\n\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":666,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":927}'\u003eAnalog 4-20mA input for level, pressure or temperature transducer\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":686,\"w\":520,\"h\":58,\"abs_x\":658,\"abs_y\":947}'\u003eUp to 8x digital 24Vdc inputs for low, stop, start, standby start and high float switches, pressure switches or thermostats, system enable\/disable input and a low flow switch\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":758,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":1019}'\u003eOutputs\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":792,\"w\":560,\"h\":97,\"abs_x\":618,\"abs_y\":1053}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":792,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1053}'\u003e3 pump output\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":812,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1073}'\u003eBMS volt-free output for common fault\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":831,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1092}'\u003eAnalog 0-10V output (mirrors analog input)\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":851,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1112}'\u003eOutput for solenoid valve available on request\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":870,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1131}'\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 bis_size='{\"x\":12,\"y\":904,\"w\":560,\"h\":22,\"abs_x\":618,\"abs_y\":1165}'\u003eCommon Applications\u003c\/h3\u003e\n\u003cul bis_size='{\"x\":12,\"y\":941,\"w\":560,\"h\":137,\"abs_x\":618,\"abs_y\":1202}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":941,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1202}'\u003eWater transfer\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":960,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1221}'\u003eTank fill\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":980,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1241}'\u003eSewage pump out\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1000,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1261}'\u003eStormwater pump out\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1019,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1280}'\u003ePressure boosting\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1039,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1300}'\u003eHot water recirculation\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1058,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1319}'\u003eChiller supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 bis_size='{\"x\":12,\"y\":1092,\"w\":560,\"h\":22,\"abs_x\":618,\"abs_y\":1353}'\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\" bis_size='{\"x\":12,\"y\":1125,\"w\":560,\"h\":106,\"abs_x\":618,\"abs_y\":1386}'\u003e\n\u003ctbody bis_size='{\"x\":15,\"y\":1128,\"w\":554,\"h\":100,\"abs_x\":621,\"abs_y\":1389}'\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":1128,\"w\":554,\"h\":23,\"abs_x\":621,\"abs_y\":1389}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":1128,\"w\":358,\"h\":23,\"abs_x\":621,\"abs_y\":1389}'\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":375,\"y\":1128,\"w\":193,\"h\":23,\"abs_x\":981,\"abs_y\":1389}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/e54d9eba0e4ab3257a8d93c1c52aaa5a00c4f088.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":377,\"y\":1130,\"w\":63,\"h\":19,\"abs_x\":983,\"abs_y\":1391}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":1154,\"w\":554,\"h\":23,\"abs_x\":621,\"abs_y\":1415}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":1154,\"w\":358,\"h\":23,\"abs_x\":621,\"abs_y\":1415}'\u003eProduct Guide\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":375,\"y\":1154,\"w\":193,\"h\":23,\"abs_x\":981,\"abs_y\":1415}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/0fde2ce949a2d88c6cf6a1fee529c31b7451011f.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":377,\"y\":1156,\"w\":63,\"h\":19,\"abs_x\":983,\"abs_y\":1417}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":1180,\"w\":554,\"h\":23,\"abs_x\":621,\"abs_y\":1441}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":1180,\"w\":358,\"h\":23,\"abs_x\":621,\"abs_y\":1441}'\u003eOperation Manual\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":375,\"y\":1180,\"w\":193,\"h\":23,\"abs_x\":981,\"abs_y\":1441}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/fdc519f87300ef0ff4be440566ef9e32807e6c39.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":377,\"y\":1182,\"w\":63,\"h\":19,\"abs_x\":983,\"abs_y\":1443}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":1205,\"w\":554,\"h\":23,\"abs_x\":621,\"abs_y\":1466}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":1205,\"w\":358,\"h\":23,\"abs_x\":621,\"abs_y\":1466}'\u003eQuick Start Guide\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":375,\"y\":1205,\"w\":193,\"h\":23,\"abs_x\":981,\"abs_y\":1466}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/c13fbd566a0336d45cfecb1d3ad611f50101893b.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":377,\"y\":1207,\"w\":63,\"h\":19,\"abs_x\":983,\"abs_y\":1468}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"-AA (1.6-2.5 Amp)","offer_id":45591611572333,"sku":"FPC-63341-AA","price":3578.96,"currency_code":"AUD","in_stock":true},{"title":"-A (2.5-4 Amp)","offer_id":45591611605101,"sku":"FPC-63341-A","price":3578.96,"currency_code":"AUD","in_stock":true},{"title":"-B (4-6 Amp)","offer_id":45591611637869,"sku":"FPC-63341-B","price":3578.96,"currency_code":"AUD","in_stock":true},{"title":"-BB (5.5-8 Amp)","offer_id":45591611670637,"sku":"FPC-63341-BB","price":3578.96,"currency_code":"AUD","in_stock":true},{"title":"-C (7-10 Amp)","offer_id":45591611703405,"sku":"FPC-63341-C","price":3578.96,"currency_code":"AUD","in_stock":true},{"title":"-D (9-13 Amp)","offer_id":45591611736173,"sku":"FPC-63341-D","price":3578.96,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPC-63341-product.webp?v=1785395770"},{"product_id":"hydrowhiz-submersible-level-controller-3ph-3-pump-fpc-63343-aa-d","title":"HydroWHIZ Submersible Level Controller (3PH 3 Pump) - FPC-63343-(AA-D)","description":"\u003cp bis_size='{\"x\":12,\"y\":9,\"w\":560,\"h\":195,\"abs_x\":618,\"abs_y\":270}'\u003eMATelec Australia's HydroWHIZ Controller has been designed with ease of use at the core of the system design. Building on the wealth of the pump control features in the Advanced controller, the HydroWHIZ brings these features into a new age with a colour touch screen interface and a streamlined setup process. In a world where information is power the HydroWHIZ has extensive time and date stamped alarms, logged data, trend graphs and diagnostic pages to provide the user with all the information required for optimisation and preventative maintenance. Featuring the flexibility of level, pressure and temperature system modes with a wide range of functions and protections, the HydroWHIZ controller is ideal for a vast range of applications including water transfer, stormwater and sewage pump out, pressure boosting, hot water circulation and chiller supply, to name a few.\u003c\/p\u003e\n\u003ch3 bis_size='{\"x\":12,\"y\":221,\"w\":560,\"h\":22,\"abs_x\":618,\"abs_y\":482}'\u003eProduct Details\u003c\/h3\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":255,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":516}'\u003eEnclosure\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":288,\"w\":560,\"h\":58,\"abs_x\":618,\"abs_y\":549}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":288,\"w\":520,\"h\":39,\"abs_x\":658,\"abs_y\":549}'\u003eIP56 rated, powder coated mild steel enclosure with inner door and removable gland plate\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":327,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":588}'\u003eEnclosure size: 400x400x250mm+\u003c\/li\u003e\n\u003cli\u003eEnclosure size will increase for high overload ratings and optional additions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":361,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":622}'\u003eProtection\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":394,\"w\":560,\"h\":97,\"abs_x\":618,\"abs_y\":655}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":394,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":655}'\u003ePad-lockable mains power isolator switch\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":414,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":675}'\u003eCircuit breaker protected low voltage control and input circuitry\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":434,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":695}'\u003eIndividual pump isolation\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":453,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":714}'\u003eContactor and thermal overload protection of pump motors\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":473,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":734}'\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":506,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":767}'\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":540,\"w\":560,\"h\":58,\"abs_x\":618,\"abs_y\":801}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":540,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":801}'\u003eHydroWHIZ colour touch screen HMI (see interface features)\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":560,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":821}'\u003eHydroWHIZ PCB control module\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":579,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":840}'\u003eVisual (strobe) and mutable audible (buzzer) alarms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":613,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":874}'\u003eInputs\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":646,\"w\":560,\"h\":117,\"abs_x\":618,\"abs_y\":907}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":646,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":907}'\u003eThree phase (400Vac) power supply\u003cbr bis_size='{\"x\":270,\"y\":646,\"w\":0,\"h\":19,\"abs_x\":876,\"abs_y\":907}'\u003e\n\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":666,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":927}'\u003eAnalog 4-20mA input for level, pressure or temperature transducer\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":686,\"w\":520,\"h\":58,\"abs_x\":658,\"abs_y\":947}'\u003eUp to 8x digital 24Vdc inputs for low, stop, start, standby start and high float switches, pressure switches or thermostats, system enable\/disable input and a low flow switch\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":744,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1005}'\u003eThermal switch inputs per pump (three phase only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":778,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":1039}'\u003eOutputs\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":812,\"w\":560,\"h\":97,\"abs_x\":618,\"abs_y\":1073}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":812,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1073}'\u003e3 pump output\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":831,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1092}'\u003eBMS volt-free output for common fault\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":851,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1112}'\u003eAnalog 0-10V output (mirrors analog input)\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":870,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1131}'\u003eOutput for solenoid valve available on request\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":890,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1151}'\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 bis_size='{\"x\":12,\"y\":924,\"w\":560,\"h\":22,\"abs_x\":618,\"abs_y\":1185}'\u003eCommon Applications\u003c\/h3\u003e\n\u003cul bis_size='{\"x\":12,\"y\":960,\"w\":560,\"h\":137,\"abs_x\":618,\"abs_y\":1221}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":960,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1221}'\u003eWater transfer\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":980,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1241}'\u003eTank fill\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1000,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1261}'\u003eSewage pump out\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1019,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1280}'\u003eStormwater pump out\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1039,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1300}'\u003ePressure boosting\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1058,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1319}'\u003eHot water recirculation\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1078,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1339}'\u003eChiller supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 bis_size='{\"x\":12,\"y\":1112,\"w\":560,\"h\":22,\"abs_x\":618,\"abs_y\":1373}'\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\" bis_size='{\"x\":12,\"y\":1145,\"w\":560,\"h\":106,\"abs_x\":618,\"abs_y\":1406}'\u003e\n\u003ctbody bis_size='{\"x\":15,\"y\":1148,\"w\":554,\"h\":100,\"abs_x\":621,\"abs_y\":1409}'\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":1148,\"w\":554,\"h\":23,\"abs_x\":621,\"abs_y\":1409}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":1148,\"w\":358,\"h\":23,\"abs_x\":621,\"abs_y\":1409}'\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":375,\"y\":1148,\"w\":193,\"h\":23,\"abs_x\":981,\"abs_y\":1409}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/e54d9eba0e4ab3257a8d93c1c52aaa5a00c4f088.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":377,\"y\":1150,\"w\":63,\"h\":19,\"abs_x\":983,\"abs_y\":1411}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":1174,\"w\":554,\"h\":23,\"abs_x\":621,\"abs_y\":1435}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":1174,\"w\":358,\"h\":23,\"abs_x\":621,\"abs_y\":1435}'\u003eProduct Guide\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":375,\"y\":1174,\"w\":193,\"h\":23,\"abs_x\":981,\"abs_y\":1435}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/0fde2ce949a2d88c6cf6a1fee529c31b7451011f.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":377,\"y\":1176,\"w\":63,\"h\":19,\"abs_x\":983,\"abs_y\":1437}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":1199,\"w\":554,\"h\":23,\"abs_x\":621,\"abs_y\":1460}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":1199,\"w\":358,\"h\":23,\"abs_x\":621,\"abs_y\":1460}'\u003eOperation Manual\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":375,\"y\":1199,\"w\":193,\"h\":23,\"abs_x\":981,\"abs_y\":1460}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/fdc519f87300ef0ff4be440566ef9e32807e6c39.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":377,\"y\":1201,\"w\":63,\"h\":19,\"abs_x\":983,\"abs_y\":1462}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":1225,\"w\":554,\"h\":23,\"abs_x\":621,\"abs_y\":1486}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":1225,\"w\":358,\"h\":23,\"abs_x\":621,\"abs_y\":1486}'\u003eQuick Start Guide\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":375,\"y\":1225,\"w\":193,\"h\":23,\"abs_x\":981,\"abs_y\":1486}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/c13fbd566a0336d45cfecb1d3ad611f50101893b.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":377,\"y\":1227,\"w\":63,\"h\":19,\"abs_x\":983,\"abs_y\":1488}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"-AA (1.6-2.5 Amp)","offer_id":45591627366509,"sku":"FPC-63343-AA","price":3769.04,"currency_code":"AUD","in_stock":true},{"title":"-A (2.5-4 Amp)","offer_id":45591627759725,"sku":"FPC-63343-A","price":3769.04,"currency_code":"AUD","in_stock":true},{"title":"-B (4-6 Amp)","offer_id":45591628152941,"sku":"FPC-63343-B","price":3769.04,"currency_code":"AUD","in_stock":true},{"title":"-BB (5.5-8 Amp)","offer_id":45591628546157,"sku":"FPC-63343-BB","price":3769.04,"currency_code":"AUD","in_stock":true},{"title":"-C (7-10 Amp)","offer_id":45591628939373,"sku":"FPC-63343-C","price":3769.04,"currency_code":"AUD","in_stock":true},{"title":"-D (9-13 Amp)","offer_id":45591629332589,"sku":"FPC-63343-D","price":3769.04,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPC-63343-product.webp?v=1785397859"},{"product_id":"hydrowhiz-submersible-level-controller-1ph-4-pump-fpc-63441-aa-d","title":"HydroWHIZ Submersible Level Controller (1PH 4 Pump) - FPC-63441-(AA-D)","description":"\u003cp\u003eMATelec Australia's HydroWHIZ Controller has been designed with ease of use at the core of the system design. Building on the wealth of the pump control features in the Advanced controller, the HydroWHIZ brings these features into a new age with a colour touch screen interface and a streamlined setup process. In a world where information is power the HydroWHIZ has extensive time and date stamped alarms, logged data, trend graphs and diagnostic pages to provide the user with all the information required for optimisation and preventative maintenance. Featuring the flexibility of level, pressure and temperature system modes with a wide range of functions and protections, the HydroWHIZ controller is ideal for a vast range of applications including water transfer, stormwater and sewage pump out, pressure boosting, hot water circulation and chiller supply, to name a few.\u003c\/p\u003e\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003ch4\u003eEnclosure\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIP56 rated, powder coated mild steel enclosure with inner door and removable gland plate\u003c\/li\u003e\n\u003cli\u003eEnclosure size: 400x400x250mm+\u003c\/li\u003e\n\u003cli\u003eEnclosure size will increase for high overload ratings and optional additions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProtection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003ePad-lockable mains power isolator switch\u003c\/li\u003e\n\u003cli\u003eCircuit breaker protected low voltage control and input circuitry\u003c\/li\u003e\n\u003cli\u003eIndividual pump isolation\u003c\/li\u003e\n\u003cli\u003eContactor and thermal overload protection of pump motors\u003c\/li\u003e\n\u003cli\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHydroWHIZ colour touch screen HMI (see interface features)\u003c\/li\u003e\n\u003cli\u003eHydroWHIZ PCB control module\u003c\/li\u003e\n\u003cli\u003eVisual (strobe) and mutable audible (buzzer) alarms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSingle phase (230Vac) power supply\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eAnalog 4-20mA input for level, pressure or temperature transducer\u003c\/li\u003e\n\u003cli\u003eUp to 8x digital 24Vdc inputs for low, stop, start, standby start and high float switches, pressure switches or thermostats, system enable\/disable input and a low flow switch\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOutputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e4 pump output\u003c\/li\u003e\n\u003cli\u003eBMS volt-free output for common fault\u003c\/li\u003e\n\u003cli\u003eAnalog 0-10V output (mirrors analog input)\u003c\/li\u003e\n\u003cli\u003eOutput for solenoid valve available on request\u003c\/li\u003e\n\u003cli\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommon Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWater transfer\u003c\/li\u003e\n\u003cli\u003eTank fill\u003c\/li\u003e\n\u003cli\u003eSewage pump out\u003c\/li\u003e\n\u003cli\u003eStormwater pump out\u003c\/li\u003e\n\u003cli\u003ePressure boosting\u003c\/li\u003e\n\u003cli\u003eHot water recirculation\u003c\/li\u003e\n\u003cli\u003eChiller supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/e54d9eba0e4ab3257a8d93c1c52aaa5a00c4f088.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/0fde2ce949a2d88c6cf6a1fee529c31b7451011f.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation Manual\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/fdc519f87300ef0ff4be440566ef9e32807e6c39.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuick Start Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/c13fbd566a0336d45cfecb1d3ad611f50101893b.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"-AA (1.6-2.5 Amp)","offer_id":45591611834477,"sku":"FPC-63441-AA","price":4488.0,"currency_code":"AUD","in_stock":true},{"title":"-A (2.5-4 Amp)","offer_id":45591611867245,"sku":"FPC-63441-A","price":4488.0,"currency_code":"AUD","in_stock":true},{"title":"-B (4-6 Amp)","offer_id":45591611900013,"sku":"FPC-63441-B","price":4488.0,"currency_code":"AUD","in_stock":true},{"title":"-BB (5.5-8 Amp)","offer_id":45591611932781,"sku":"FPC-63441-BB","price":4488.0,"currency_code":"AUD","in_stock":true},{"title":"-C (7-10 Amp)","offer_id":45591611965549,"sku":"FPC-63441-C","price":4488.0,"currency_code":"AUD","in_stock":true},{"title":"-D (9-13 Amp)","offer_id":45591611998317,"sku":"FPC-63441-D","price":4488.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPC-63441-product.webp?v=1785399085"},{"product_id":"hydrowhiz-submersible-level-controller-3ph-4-pump-fpc-63443-aa-d","title":"HydroWHIZ Submersible Level Controller (3PH 4 Pump) - FPC-63443-(AA-D)","description":"\u003cp bis_size='{\"x\":12,\"y\":9,\"w\":560,\"h\":195,\"abs_x\":618,\"abs_y\":270}'\u003eMATelec Australia's HydroWHIZ Controller has been designed with ease of use at the core of the system design. Building on the wealth of the pump control features in the Advanced controller, the HydroWHIZ brings these features into a new age with a colour touch screen interface and a streamlined setup process. In a world where information is power the HydroWHIZ has extensive time and date stamped alarms, logged data, trend graphs and diagnostic pages to provide the user with all the information required for optimisation and preventative maintenance. Featuring the flexibility of level, pressure and temperature system modes with a wide range of functions and protections, the HydroWHIZ controller is ideal for a vast range of applications including water transfer, stormwater and sewage pump out, pressure boosting, hot water circulation and chiller supply, to name a few.\u003c\/p\u003e\n\u003ch3 bis_size='{\"x\":12,\"y\":221,\"w\":560,\"h\":22,\"abs_x\":618,\"abs_y\":482}'\u003eProduct Details\u003c\/h3\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":255,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":516}'\u003eEnclosure\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":288,\"w\":560,\"h\":58,\"abs_x\":618,\"abs_y\":549}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":288,\"w\":520,\"h\":39,\"abs_x\":658,\"abs_y\":549}'\u003eIP56 rated, powder coated mild steel enclosure with inner door and removable gland plate\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":327,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":588}'\u003eEnclosure size: 500x500x350mm+\u003c\/li\u003e\n\u003cli\u003eEnclosure size will increase for high overload ratings and optional additions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":361,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":622}'\u003eProtection\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":394,\"w\":560,\"h\":97,\"abs_x\":618,\"abs_y\":655}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":394,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":655}'\u003ePad-lockable mains power isolator switch\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":414,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":675}'\u003eCircuit breaker protected low voltage control and input circuitry\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":434,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":695}'\u003eIndividual pump isolation\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":453,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":714}'\u003eContactor and thermal overload protection of pump motors\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":473,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":734}'\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":506,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":767}'\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":540,\"w\":560,\"h\":58,\"abs_x\":618,\"abs_y\":801}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":540,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":801}'\u003eHydroWHIZ colour touch screen HMI (see interface features)\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":560,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":821}'\u003eHydroWHIZ PCB control module\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":579,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":840}'\u003eVisual (strobe) and mutable audible (buzzer) alarms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":613,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":874}'\u003eInputs\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":646,\"w\":560,\"h\":117,\"abs_x\":618,\"abs_y\":907}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":646,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":907}'\u003eThree phase (400Vac) power supply\u003cbr bis_size='{\"x\":270,\"y\":646,\"w\":0,\"h\":19,\"abs_x\":876,\"abs_y\":907}'\u003e\n\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":666,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":927}'\u003eAnalog 4-20mA input for level, pressure or temperature transducer\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":686,\"w\":520,\"h\":58,\"abs_x\":658,\"abs_y\":947}'\u003eUp to 8x digital 24Vdc inputs for low, stop, start, standby start and high float switches, pressure switches or thermostats, system enable\/disable input and a low flow switch\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":744,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1005}'\u003eThermal switch inputs per pump (three phase only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":778,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":1039}'\u003eOutputs\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":812,\"w\":560,\"h\":97,\"abs_x\":618,\"abs_y\":1073}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":812,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1073}'\u003e4 pump output\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":831,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1092}'\u003eBMS volt-free output for common fault\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":851,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1112}'\u003eAnalog 0-10V output (mirrors analog input)\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":870,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1131}'\u003eOutput for solenoid valve available on request\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":890,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1151}'\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 bis_size='{\"x\":12,\"y\":924,\"w\":560,\"h\":22,\"abs_x\":618,\"abs_y\":1185}'\u003eCommon Applications\u003c\/h3\u003e\n\u003cul bis_size='{\"x\":12,\"y\":960,\"w\":560,\"h\":137,\"abs_x\":618,\"abs_y\":1221}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":960,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1221}'\u003eWater transfer\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":980,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1241}'\u003eTank fill\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1000,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1261}'\u003eSewage pump out\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1019,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1280}'\u003eStormwater pump out\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1039,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1300}'\u003ePressure boosting\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1058,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1319}'\u003eHot water recirculation\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1078,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1339}'\u003eChiller supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 bis_size='{\"x\":12,\"y\":1112,\"w\":560,\"h\":22,\"abs_x\":618,\"abs_y\":1373}'\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\" bis_size='{\"x\":12,\"y\":1145,\"w\":560,\"h\":106,\"abs_x\":618,\"abs_y\":1406}'\u003e\n\u003ctbody bis_size='{\"x\":15,\"y\":1148,\"w\":554,\"h\":100,\"abs_x\":621,\"abs_y\":1409}'\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":1148,\"w\":554,\"h\":23,\"abs_x\":621,\"abs_y\":1409}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":1148,\"w\":358,\"h\":23,\"abs_x\":621,\"abs_y\":1409}'\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":375,\"y\":1148,\"w\":193,\"h\":23,\"abs_x\":981,\"abs_y\":1409}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/e54d9eba0e4ab3257a8d93c1c52aaa5a00c4f088.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":377,\"y\":1150,\"w\":63,\"h\":19,\"abs_x\":983,\"abs_y\":1411}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":1174,\"w\":554,\"h\":23,\"abs_x\":621,\"abs_y\":1435}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":1174,\"w\":358,\"h\":23,\"abs_x\":621,\"abs_y\":1435}'\u003eProduct Guide\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":375,\"y\":1174,\"w\":193,\"h\":23,\"abs_x\":981,\"abs_y\":1435}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/0fde2ce949a2d88c6cf6a1fee529c31b7451011f.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":377,\"y\":1176,\"w\":63,\"h\":19,\"abs_x\":983,\"abs_y\":1437}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":1199,\"w\":554,\"h\":23,\"abs_x\":621,\"abs_y\":1460}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":1199,\"w\":358,\"h\":23,\"abs_x\":621,\"abs_y\":1460}'\u003eOperation Manual\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":375,\"y\":1199,\"w\":193,\"h\":23,\"abs_x\":981,\"abs_y\":1460}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/fdc519f87300ef0ff4be440566ef9e32807e6c39.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":377,\"y\":1201,\"w\":63,\"h\":19,\"abs_x\":983,\"abs_y\":1462}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":1225,\"w\":554,\"h\":23,\"abs_x\":621,\"abs_y\":1486}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":1225,\"w\":358,\"h\":23,\"abs_x\":621,\"abs_y\":1486}'\u003eQuick Start Guide\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":375,\"y\":1225,\"w\":193,\"h\":23,\"abs_x\":981,\"abs_y\":1486}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/c13fbd566a0336d45cfecb1d3ad611f50101893b.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":377,\"y\":1227,\"w\":63,\"h\":19,\"abs_x\":983,\"abs_y\":1488}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"-AA (1.6-2.5 Amp)","offer_id":45591630413933,"sku":"FPC-63443-AA","price":4641.12,"currency_code":"AUD","in_stock":true},{"title":"-A (2.5-4 Amp)","offer_id":45591630446701,"sku":"FPC-63443-A","price":4641.12,"currency_code":"AUD","in_stock":true},{"title":"-B (4-6 Amp)","offer_id":45591630479469,"sku":"FPC-63443-B","price":4641.12,"currency_code":"AUD","in_stock":true},{"title":"-BB (5.5-8 Amp)","offer_id":45591630512237,"sku":"FPC-63443-BB","price":4641.12,"currency_code":"AUD","in_stock":true},{"title":"-C (7-10 Amp)","offer_id":45591630545005,"sku":"FPC-63443-C","price":4641.12,"currency_code":"AUD","in_stock":true},{"title":"-D (9-13 Amp)","offer_id":45591630577773,"sku":"FPC-63443-D","price":4641.12,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPC-63443-product.webp?v=1785399898"},{"product_id":"hydrostart-hwc-1ph-2-pump-0-1-16a-fpc-81241","title":"HydroSTART Hot Water Controller (1PH 2 Pump 0.1-16A) - FPC-81241-HWC","description":"\u003cp bis_size='{\"x\":12,\"y\":9,\"w\":560,\"h\":78,\"abs_x\":618,\"abs_y\":270}'\u003eMATelec Australia's HydroSTART Controller brings the features of the standard single and dual pump controllers into a new age with a redesigned capacitive touch keypad and control module with pump current sensing, providing wide range electronic overload protection which now functions with both single and three phase pumps.\u003c\/p\u003e\n\u003cp bis_size='{\"x\":12,\"y\":103,\"w\":560,\"h\":58,\"abs_x\":618,\"abs_y\":364}'\u003eAdditional control inputs and functionality have been incorporated into the new design to enhance the controller's flexibility and cover an even wider range of pumping applications. The HydroSTART is the new standard for pump controls.\u003c\/p\u003e\n\u003ch3 bis_size='{\"x\":12,\"y\":178,\"w\":560,\"h\":22,\"abs_x\":618,\"abs_y\":439}'\u003eProduct Details\u003c\/h3\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":212,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":473}'\u003eEnclosure\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":245,\"w\":560,\"h\":58,\"abs_x\":618,\"abs_y\":506}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":245,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":506}'\u003eEnclosure size: 400x300x150mm\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":265,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":526}'\u003ePowder coated mild steel enclosure with removable gland plate\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":285,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":546}'\u003e\u003cspan bis_size='{\"x\":52,\"y\":285,\"w\":148,\"h\":19,\"abs_x\":658,\"abs_y\":546}'\u003eIP54 rated single door for indoor mounting (single door version) \u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":318,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":579}'\u003eProtection\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":352,\"w\":560,\"h\":137,\"abs_x\":618,\"abs_y\":613}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":352,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":613}'\u003eSelectable overload range: 0.1-6 Amp, 5-16 Amp\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":371,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":632}'\u003ePad-lockable mains power isolator switch\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":391,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":652}'\u003eLow voltage control and input circuitry\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":410,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":671}'\u003eIndividual pump circuit breaker protection\/isolation\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":430,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":691}'\u003eContactors for pump switching (three-phase panels)\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":450,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":711}'\u003eElectronic short and overload protection of alarms\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":469,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":730}'\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":503,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":764}'\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":536,\"w\":560,\"h\":117,\"abs_x\":618,\"abs_y\":797}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":536,\"w\":520,\"h\":58,\"abs_x\":658,\"abs_y\":797}'\u003eHydroSTART single or dual pump capacitive touch keypad interface:\n\u003cul bis_size='{\"x\":52,\"y\":556,\"w\":520,\"h\":39,\"abs_x\":658,\"abs_y\":817}'\u003e\n\u003cli bis_size='{\"x\":92,\"y\":556,\"w\":480,\"h\":19,\"abs_x\":698,\"abs_y\":817}'\u003eIndicator lights for system and pump status\u003c\/li\u003e\n\u003cli bis_size='{\"x\":92,\"y\":576,\"w\":480,\"h\":19,\"abs_x\":698,\"abs_y\":837}'\u003eButtons for alarm mute\/reset and pump mode selection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":595,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":856}'\u003eHydroSTART PCB control module with dipswitches for adjusting configuration\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":615,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":876}'\u003eVisual (strobe) and audible (buzzer) alarms\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":634,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":895}'\u003ePump current sensing providing adjustable overload \u0026amp; other protections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":668,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":929}'\u003eInputs\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":702,\"w\":560,\"h\":58,\"abs_x\":618,\"abs_y\":963}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":702,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":963}'\u003eSingle phase (230Vac) power supply\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":721,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":982}'\u003eDigital input for thermostat and time clock\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":741,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1002}'\u003eHot water terminal set up, with volt free BMS outputs and system enable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":774,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":1035}'\u003eOutputs\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":808,\"w\":560,\"h\":58,\"abs_x\":618,\"abs_y\":1069}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":808,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1069}'\u003e2x pump supply outputs\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":828,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1089}'\u003eBMS volt-free output for common fault\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":847,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1108}'\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 bis_size='{\"x\":12,\"y\":881,\"w\":560,\"h\":22,\"abs_x\":618,\"abs_y\":1142}'\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\" bis_size='{\"x\":12,\"y\":914,\"w\":560,\"h\":106,\"abs_x\":618,\"abs_y\":1175}'\u003e\n\u003ctbody bis_size='{\"x\":15,\"y\":917,\"w\":554,\"h\":100,\"abs_x\":621,\"abs_y\":1178}'\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":917,\"w\":554,\"h\":23,\"abs_x\":621,\"abs_y\":1178}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":917,\"w\":358,\"h\":23,\"abs_x\":621,\"abs_y\":1178}'\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":375,\"y\":917,\"w\":193,\"h\":23,\"abs_x\":981,\"abs_y\":1178}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/08f5a11902b64509503920491cac62bb60c5a92e.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":377,\"y\":919,\"w\":63,\"h\":19,\"abs_x\":983,\"abs_y\":1180}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":943,\"w\":554,\"h\":23,\"abs_x\":621,\"abs_y\":1204}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":943,\"w\":358,\"h\":23,\"abs_x\":621,\"abs_y\":1204}'\u003eProduct Guide\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":375,\"y\":943,\"w\":193,\"h\":23,\"abs_x\":981,\"abs_y\":1204}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/0fde2ce949a2d88c6cf6a1fee529c31b7451011f.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":377,\"y\":945,\"w\":63,\"h\":19,\"abs_x\":983,\"abs_y\":1206}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":968,\"w\":554,\"h\":23,\"abs_x\":621,\"abs_y\":1229}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":968,\"w\":358,\"h\":23,\"abs_x\":621,\"abs_y\":1229}'\u003eOperation Manual\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":375,\"y\":968,\"w\":193,\"h\":23,\"abs_x\":981,\"abs_y\":1229}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/2bd7c38a494e8c01cbfb4d1f1189308a61b1a103.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":377,\"y\":970,\"w\":63,\"h\":19,\"abs_x\":983,\"abs_y\":1231}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":994,\"w\":554,\"h\":23,\"abs_x\":621,\"abs_y\":1255}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":994,\"w\":358,\"h\":23,\"abs_x\":621,\"abs_y\":1255}'\u003eQuick Start Guide\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":375,\"y\":994,\"w\":193,\"h\":23,\"abs_x\":981,\"abs_y\":1255}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/85a2dcb6f7983bd6b95a1a57c28f6e6839cb322b.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":377,\"y\":996,\"w\":63,\"h\":19,\"abs_x\":983,\"abs_y\":1257}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"0.1-6amp","offer_id":45615482077293,"sku":"FPC-81241-HWC-1","price":1654.4,"currency_code":"AUD","in_stock":true},{"title":"5-16 amp","offer_id":45615482110061,"sku":"FPC-81241-HWC-2","price":1654.4,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPC-81241-product.webp?v=1785465493"},{"product_id":"hydrostart-hwc-1ph-2-pump-0-1-10a-fpc-81241-qp","title":"HydroSTART Hot Water Controller (1PH 2 Pump 0.1-10A with Quick Plug) - FPC-81241-HWC\/QP","description":"\u003cp\u003eMATelec Australia's HydroSTART Controller brings the features of the standard single and dual pump controllers into a new age with a redesigned capacitive touch keypad and control module with pump current sensing, providing wide range electronic overload protection which now functions with both single and three phase pumps.\u003c\/p\u003e\n\u003cp\u003eAdditional control inputs and functionality have been incorporated into the new design to enhance the controller's flexibility and cover an even wider range of pumping applications. The HydroSTART is the new standard for pump controls.\u003c\/p\u003e\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003ch4\u003eEnclosure\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eEnclosure size: 400x300x150mm\u003c\/li\u003e\n\u003cli\u003ePowder coated mild steel enclosure with removable gland plate\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIP54 rated single door for indoor mounting (single door version) \u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProtection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSelectable overload range: 0.1-6 Amp, 5-16 Amp\u003c\/li\u003e\n\u003cli\u003ePad-lockable mains power isolator switch\u003c\/li\u003e\n\u003cli\u003eLow voltage control and input circuitry\u003c\/li\u003e\n\u003cli\u003eIndividual pump circuit breaker protection\/isolation\u003c\/li\u003e\n\u003cli\u003eContactors for pump switching (three-phase panels)\u003c\/li\u003e\n\u003cli\u003eElectronic short and overload protection of alarms\u003c\/li\u003e\n\u003cli\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHydroSTART single or dual pump capacitive touch keypad interface:\n\u003cul\u003e\n\u003cli\u003eIndicator lights for system and pump status\u003c\/li\u003e\n\u003cli\u003eButtons for alarm mute\/reset and pump mode selection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eHydroSTART PCB control module with dipswitches for adjusting configuration\u003c\/li\u003e\n\u003cli\u003eVisual (strobe) and audible (buzzer) alarms\u003c\/li\u003e\n\u003cli\u003ePump current sensing providing adjustable overload \u0026amp; other protections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSingle phase (230Vac) power supply\u003c\/li\u003e\n\u003cli\u003eDigital input for thermostat and time clock\u003c\/li\u003e\n\u003cli\u003eHot water terminal set up, with volt free BMS outputs and system enable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOutputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e2x pump supply outputs\u003c\/li\u003e\n\u003cli\u003eBMS volt-free output for common fault\u003c\/li\u003e\n\u003cli\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/08f5a11902b64509503920491cac62bb60c5a92e.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/0fde2ce949a2d88c6cf6a1fee529c31b7451011f.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation Manual\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/2bd7c38a494e8c01cbfb4d1f1189308a61b1a103.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuick Start Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/85a2dcb6f7983bd6b95a1a57c28f6e6839cb322b.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"0.1-6amp","offer_id":45615479881837,"sku":"FPC-81241-HWC\/QP-1","price":1694.0,"currency_code":"AUD","in_stock":true},{"title":"5-16 amp","offer_id":45615479914605,"sku":"FPC-81241-HWC\/QP-2","price":1694.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPC-81241-QP-product.webp?v=1785465773"},{"product_id":"hydrostart-hwc-1ph-2-pump-0-1-16a-c-w-time-clock-fpc-81241","title":"HydroSTART Hot Water Controller (1PH 2 Pump 0.1-16A with Time Clock) - FPC-81241-HWC\/TC","description":"\u003cp\u003eMATelec Australia's HydroSTART Controller brings the features of the standard single and dual pump controllers into a new age with a redesigned capacitive touch keypad and control module with pump current sensing, providing wide range electronic overload protection which now functions with both single and three phase pumps.\u003c\/p\u003e\n\u003cp\u003eAdditional control inputs and functionality have been incorporated into the new design to enhance the controller's flexibility and cover an even wider range of pumping applications. The HydroSTART is the new standard for pump controls.\u003c\/p\u003e\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003ch4\u003eEnclosure\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eEnclosure size: 400x300x150mm\u003c\/li\u003e\n\u003cli\u003ePowder coated mild steel enclosure with removable gland plate\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIP54 rated single door\u003cspan\u003e for indoor mounting (single door version) \u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProtection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSelectable overload range: 0.1-6 Amp, 5-16 Amp\u003c\/li\u003e\n\u003cli\u003ePad-lockable mains power isolator switch\u003c\/li\u003e\n\u003cli\u003eLow voltage control and input circuitry\u003c\/li\u003e\n\u003cli\u003eIndividual pump circuit breaker protection\/isolation\u003c\/li\u003e\n\u003cli\u003eContactors for pump switching (three-phase panels)\u003c\/li\u003e\n\u003cli\u003eElectronic short and overload protection of alarms\u003c\/li\u003e\n\u003cli\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHydroSTART single or dual pump capacitive touch keypad interface:\n\u003cul\u003e\n\u003cli\u003eIndicator lights for system and pump status\u003c\/li\u003e\n\u003cli\u003eButtons for alarm mute\/reset and pump mode selection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eHydroSTART PCB control module with dipswitches for adjusting configuration\u003c\/li\u003e\n\u003cli\u003eVisual (strobe) and audible (buzzer) alarms\u003c\/li\u003e\n\u003cli\u003ePump current sensing providing adjustable overload \u0026amp; other protections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSingle phase (230Vac) power supply\u003c\/li\u003e\n\u003cli\u003eDigital input for thermostat and time clock\u003c\/li\u003e\n\u003cli\u003eHot water terminal set up, with volt free BMS outputs and system enable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOutputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e2x pump supply outputs\u003c\/li\u003e\n\u003cli\u003eBMS volt-free output for common fault\u003c\/li\u003e\n\u003cli\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/08f5a11902b64509503920491cac62bb60c5a92e.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/0fde2ce949a2d88c6cf6a1fee529c31b7451011f.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation Manual\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/2bd7c38a494e8c01cbfb4d1f1189308a61b1a103.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuick Start Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/85a2dcb6f7983bd6b95a1a57c28f6e6839cb322b.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"0.1-6amp","offer_id":45615477948525,"sku":"FPC-81241-HWC\/TC-1","price":1749.44,"currency_code":"AUD","in_stock":true},{"title":"5-16 amp","offer_id":45615477981293,"sku":"FPC-81241-HWC\/TC-2","price":1749.44,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPC-81241-TC-product.webp?v=1785466240"},{"product_id":"hydrostart-hwc-1ph-2-pump-0-1-16a-c-w-id-fpc-82241","title":"HydroSTART Hot Water Controller (1PH 2 Pump 0.1-16A with ID) - FPC-82241-HWC","description":"\u003cp\u003eMATelec Australia's HydroSTART Controller brings the features of the standard single and dual pump controllers into a new age with a redesigned capacitive touch keypad and control module with pump current sensing, providing wide range electronic overload protection which now functions with both single and three phase pumps.\u003c\/p\u003e\n\u003cp\u003eAdditional control inputs and functionality have been incorporated into the new design to enhance the controller's flexibility and cover an even wider range of pumping applications. The HydroSTART is the new standard for pump controls.\u003c\/p\u003e\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003ch4\u003eEnclosure\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eEnclosure size: 400x400x200mm\u003c\/li\u003e\n\u003cli\u003ePowder coated mild steel enclosure with removable gland plate\u003c\/li\u003e\n\u003cli\u003eIP56 rated with inner door for outdoor mounting (inner door version)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProtection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSelectable overload range: 0.1-6 Amp, 5-16 Amp\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003ePad-lockable mains power isolator switch\u003c\/li\u003e\n\u003cli\u003eLow voltage control and input circuitry\u003c\/li\u003e\n\u003cli\u003eIndividual pump circuit breaker protection\/isolation\u003c\/li\u003e\n\u003cli\u003eContactors for pump switching (three-phase panels)\u003c\/li\u003e\n\u003cli\u003eElectronic short and overload protection of alarms\u003c\/li\u003e\n\u003cli\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHydroSTART single or dual pump capacitive touch keypad interface:\n\u003cul\u003e\n\u003cli\u003eIndicator lights for system and pump status\u003c\/li\u003e\n\u003cli\u003eButtons for alarm mute\/reset and pump mode selection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eHydroSTART PCB control module with dipswitches for adjusting configuration\u003c\/li\u003e\n\u003cli\u003eVisual (strobe) and audible (buzzer) alarms\u003c\/li\u003e\n\u003cli\u003ePump current sensing providing adjustable overload \u0026amp; other protections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSingle phase (230Vac) power supply\u003c\/li\u003e\n\u003cli\u003eDigital input for thermostat and time clock\u003c\/li\u003e\n\u003cli\u003eHot water terminal set up, with volt free BMS outputs and system enable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOutputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e2x pump supply outputs\u003c\/li\u003e\n\u003cli\u003eBMS volt-free output for common fault\u003c\/li\u003e\n\u003cli\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/08f5a11902b64509503920491cac62bb60c5a92e.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/0fde2ce949a2d88c6cf6a1fee529c31b7451011f.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation Manual\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/2bd7c38a494e8c01cbfb4d1f1189308a61b1a103.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuick Start Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/85a2dcb6f7983bd6b95a1a57c28f6e6839cb322b.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"0.1-6amp","offer_id":45615470051437,"sku":"FPC-82241-HWC-1","price":1716.0,"currency_code":"AUD","in_stock":true},{"title":"5-16 amp","offer_id":45615470084205,"sku":"FPC-82241-HWC-2","price":1716.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPC-82241-ID-product.webp?v=1785468967"},{"product_id":"hydrostart-hwc-1ph-2-pump-0-1-16a-c-w-id-time-clock-fpc-82241","title":"HydroSTART Hot Water Controller (1PH 2 Pump 0.1-16A with ID \u0026 Time Clock) - FPC-82241-HWC\/TC","description":"\u003cp\u003eMATelec Australia's HydroSTART Controller brings the features of the standard single and dual pump controllers into a new age with a redesigned capacitive touch keypad and control module with pump current sensing, providing wide range electronic overload protection which now functions with both single and three phase pumps.\u003c\/p\u003e\n\u003cp\u003eAdditional control inputs and functionality have been incorporated into the new design to enhance the controller's flexibility and cover an even wider range of pumping applications. The HydroSTART is the new standard for pump controls.\u003c\/p\u003e\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003ch4\u003eEnclosure\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eEnclosure size: 400x400x200mm\u003c\/li\u003e\n\u003cli\u003ePowder coated mild steel enclosure with removable gland plate\u003c\/li\u003e\n\u003cli\u003eIP56 rated with inner door for outdoor mounting (inner door version)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProtection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSelectable overload range: 0.1-6 Amp, 5-16 Amp\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003ePad-lockable mains power isolator switch\u003c\/li\u003e\n\u003cli\u003eLow voltage control and input circuitry\u003c\/li\u003e\n\u003cli\u003eIndividual pump circuit breaker protection\/isolation\u003c\/li\u003e\n\u003cli\u003eContactors for pump switching (three-phase panels)\u003c\/li\u003e\n\u003cli\u003eElectronic short and overload protection of alarms\u003c\/li\u003e\n\u003cli\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHydroSTART single or dual pump capacitive touch keypad interface:\n\u003cul\u003e\n\u003cli\u003eIndicator lights for system and pump status\u003c\/li\u003e\n\u003cli\u003eButtons for alarm mute\/reset and pump mode selection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eHydroSTART PCB control module with dipswitches for adjusting configuration\u003c\/li\u003e\n\u003cli\u003eVisual (strobe) and audible (buzzer) alarms\u003c\/li\u003e\n\u003cli\u003ePump current sensing providing adjustable overload \u0026amp; other protections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSingle phase (230Vac) power supply\u003c\/li\u003e\n\u003cli\u003eDigital input for thermostat and time clock\u003c\/li\u003e\n\u003cli\u003eHot water terminal set up, with volt free BMS outputs and system enable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOutputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e2x pump supply outputs\u003c\/li\u003e\n\u003cli\u003eBMS volt-free output for common fault\u003c\/li\u003e\n\u003cli\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/08f5a11902b64509503920491cac62bb60c5a92e.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/0fde2ce949a2d88c6cf6a1fee529c31b7451011f.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation Manual\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/2bd7c38a494e8c01cbfb4d1f1189308a61b1a103.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuick Start Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/85a2dcb6f7983bd6b95a1a57c28f6e6839cb322b.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"0.1-6amp","offer_id":45615467167853,"sku":"FPC-82241-HWC\/TC-1","price":1803.12,"currency_code":"AUD","in_stock":true},{"title":"5-16 amp","offer_id":45615467200621,"sku":"FPC-82241-HWC\/TC-2","price":1803.12,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPC-82241-TC-product.webp?v=1785469180"},{"product_id":"hydrostart-hwc-1ph-2-pump-0-1-16a-c-w-id-tc-bms-fpc-82241","title":"HydroSTART Hot Water Controller (1PH 2 Pump 0.1-16A with ID, TC \u0026 BMS) - FPC-82241-HWC\/TC\/BMS","description":"\u003cp\u003eMATelec Australia's HydroSTART Controller brings the features of the standard single and dual pump controllers into a new age with a redesigned capacitive touch keypad and control module with pump current sensing, providing wide range electronic overload protection which now functions with both single and three phase pumps.\u003c\/p\u003e\n\u003cp\u003eAdditional control inputs and functionality have been incorporated into the new design to enhance the controller's flexibility and cover an even wider range of pumping applications. The HydroSTART is the new standard for pump controls.\u003c\/p\u003e\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003ch4\u003eEnclosure\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eEnclosure size: 400x400x200mm\u003c\/li\u003e\n\u003cli\u003ePowder coated mild steel enclosure with removable gland plate\u003c\/li\u003e\n\u003cli\u003eIP56 rated with inner door for outdoor mounting (inner door version)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProtection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSelectable overload range: 0.1-6 Amp, 5-16 Amp\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003ePad-lockable mains power isolator switch\u003c\/li\u003e\n\u003cli\u003eLow voltage control and input circuitry\u003c\/li\u003e\n\u003cli\u003eIndividual pump circuit breaker protection\/isolation\u003c\/li\u003e\n\u003cli\u003eContactors for pump switching (three-phase panels)\u003c\/li\u003e\n\u003cli\u003eElectronic short and overload protection of alarms\u003c\/li\u003e\n\u003cli\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHydroSTART single or dual pump capacitive touch keypad interface:\n\u003cul\u003e\n\u003cli\u003eIndicator lights for system and pump status\u003c\/li\u003e\n\u003cli\u003eButtons for alarm mute\/reset and pump mode selection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eHydroSTART PCB control module with dipswitches for adjusting configuration\u003c\/li\u003e\n\u003cli\u003eVisual (strobe) and audible (buzzer) alarms\u003c\/li\u003e\n\u003cli\u003ePump current sensing providing adjustable overload \u0026amp; other protections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSingle phase (230Vac) power supply\u003c\/li\u003e\n\u003cli\u003eDigital input for thermostat and time clock\u003c\/li\u003e\n\u003cli\u003eHot water terminal set up, with volt free BMS outputs and system enable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOutputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e2x pump supply outputs\u003c\/li\u003e\n\u003cli\u003eBMS volt-free output for common fault\u003c\/li\u003e\n\u003cli\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/08f5a11902b64509503920491cac62bb60c5a92e.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/0fde2ce949a2d88c6cf6a1fee529c31b7451011f.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation Manual\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/2bd7c38a494e8c01cbfb4d1f1189308a61b1a103.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuick Start Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/85a2dcb6f7983bd6b95a1a57c28f6e6839cb322b.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"0.1-6amp","offer_id":45615465758829,"sku":"FPC-82241-HWC\/TC\/BMS-1","price":2351.36,"currency_code":"AUD","in_stock":true},{"title":"5-16 amp","offer_id":45615465791597,"sku":"FPC-82241-HWC\/TC\/BMS-2","price":2351.36,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPC-82241-TC-BMS-product.webp?v=1785471551"},{"product_id":"hydrostart-hwc-3ph-2-pump-0-1-16a-c-w-id-fpc-82243","title":"HydroSTART Hot Water Controller (3PH 2 Pump 0.1-16A with ID) - FPC-82243-HWC","description":"\u003cp\u003eMATelec Australia's HydroSTART Controller brings the features of the standard single and dual pump controllers into a new age with a redesigned capacitive touch keypad and control module with pump current sensing, providing wide range electronic overload protection which now functions with both single and three phase pumps.\u003c\/p\u003e\n\u003cp\u003eAdditional control inputs and functionality have been incorporated into the new design to enhance the controller's flexibility and cover an even wider range of pumping applications. The HydroSTART is the new standard for pump controls.\u003c\/p\u003e\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003ch4\u003eEnclosure\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eEnclosure size: 400x400x200mm\u003c\/li\u003e\n\u003cli\u003ePowder coated mild steel enclosure with removable gland plate\u003c\/li\u003e\n\u003cli\u003eIP56 rated with inner door for outdoor mounting (inner door version)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProtection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSelectable overload range: 0.1-6 Amp, 5-16 Amp\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003ePad-lockable mains power isolator switch\u003c\/li\u003e\n\u003cli\u003eLow voltage control and input circuitry\u003c\/li\u003e\n\u003cli\u003eIndividual pump circuit breaker protection\/isolation\u003c\/li\u003e\n\u003cli\u003eContactors for pump switching (three-phase panels)\u003c\/li\u003e\n\u003cli\u003eElectronic short and overload protection of alarms\u003c\/li\u003e\n\u003cli\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHydroSTART single or dual pump capacitive touch keypad interface:\n\u003cul\u003e\n\u003cli\u003eIndicator lights for system and pump status\u003c\/li\u003e\n\u003cli\u003eButtons for alarm mute\/reset and pump mode selection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eHydroSTART PCB control module with dipswitches for adjusting configuration\u003c\/li\u003e\n\u003cli\u003eVisual (strobe) and audible (buzzer) alarms\u003c\/li\u003e\n\u003cli\u003ePump current sensing providing adjustable overload \u0026amp; other protections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThree phase (400Vac) power supply \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eDigital input for thermostat and time clock\u003c\/li\u003e\n\u003cli\u003eHot water terminal set up, with volt free BMS outputs and system enable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOutputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e2x pump supply outputs\u003c\/li\u003e\n\u003cli\u003eBMS volt-free output for common fault\u003c\/li\u003e\n\u003cli\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/08f5a11902b64509503920491cac62bb60c5a92e.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/0fde2ce949a2d88c6cf6a1fee529c31b7451011f.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation Manual\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/2bd7c38a494e8c01cbfb4d1f1189308a61b1a103.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuick Start Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/85a2dcb6f7983bd6b95a1a57c28f6e6839cb322b.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"0.1-6amp","offer_id":45615492661357,"sku":"FPC-82243-HWC-1","price":1807.52,"currency_code":"AUD","in_stock":true},{"title":"5-16 amp","offer_id":45615492694125,"sku":"FPC-82243-HWC-2","price":1807.52,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPC-82243-ID-product.webp?v=1785473370"},{"product_id":"hydrostart-hwc-3ph-2-pump-0-1-16a-c-w-id-tc-fpc-82243","title":"HydroSTART Hot Water Controller (3PH 2 Pump 0.1-16A with ID \u0026 TC) - FPC-82243-HWC\/TC","description":"\u003cp\u003eMATelec Australia's HydroSTART Controller brings the features of the standard single and dual pump controllers into a new age with a redesigned capacitive touch keypad and control module with pump current sensing, providing wide range electronic overload protection which now functions with both single and three phase pumps.\u003c\/p\u003e\n\u003cp\u003eAdditional control inputs and functionality have been incorporated into the new design to enhance the controller's flexibility and cover an even wider range of pumping applications. The HydroSTART is the new standard for pump controls.\u003c\/p\u003e\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003ch4\u003eEnclosure\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eEnclosure size: 400x400x200mm\u003c\/li\u003e\n\u003cli\u003ePowder coated mild steel enclosure with removable gland plate\u003c\/li\u003e\n\u003cli\u003eIP56 rated with inner door for outdoor mounting (inner door version)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProtection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSelectable overload range: 0.1-6 Amp, 5-16 Amp\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003ePad-lockable mains power isolator switch\u003c\/li\u003e\n\u003cli\u003eLow voltage control and input circuitry\u003c\/li\u003e\n\u003cli\u003eIndividual pump circuit breaker protection\/isolation\u003c\/li\u003e\n\u003cli\u003eContactors for pump switching (three-phase panels)\u003c\/li\u003e\n\u003cli\u003eElectronic short and overload protection of alarms\u003c\/li\u003e\n\u003cli\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHydroSTART single or dual pump capacitive touch keypad interface:\n\u003cul\u003e\n\u003cli\u003eIndicator lights for system and pump status\u003c\/li\u003e\n\u003cli\u003eButtons for alarm mute\/reset and pump mode selection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eHydroSTART PCB control module with dipswitches for adjusting configuration\u003c\/li\u003e\n\u003cli\u003eVisual (strobe) and audible (buzzer) alarms\u003c\/li\u003e\n\u003cli\u003ePump current sensing providing adjustable overload \u0026amp; other protections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThree phase (400Vac) power supply \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eDigital input for thermostat and time clock\u003c\/li\u003e\n\u003cli\u003eHot water terminal set up, with volt free BMS outputs and system enable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOutputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e2x pump supply outputs\u003c\/li\u003e\n\u003cli\u003eBMS volt-free output for common fault\u003c\/li\u003e\n\u003cli\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/08f5a11902b64509503920491cac62bb60c5a92e.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/0fde2ce949a2d88c6cf6a1fee529c31b7451011f.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation Manual\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/2bd7c38a494e8c01cbfb4d1f1189308a61b1a103.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuick Start Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/85a2dcb6f7983bd6b95a1a57c28f6e6839cb322b.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"0.1-6amp","offer_id":45615456551021,"sku":"FPC-82243-HWC\/TC-2","price":2759.68,"currency_code":"AUD","in_stock":true},{"title":"5-16 amp","offer_id":45615456583789,"sku":"FPC-82243-HWC\/TC-1","price":2759.68,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPC-82243-ID-TC-product.webp?v=1785473553"},{"product_id":"hydrostart-hwc-3ph-2-pump-0-1-16a-c-w-id-tc-bms-fpc-82243","title":"HydroSTART Hot Water Controller (3PH 2 Pump 0.1-16A with ID, TC \u0026 BMS) - FPC-82243-HWC\/TC\/BMS","description":"\u003cp\u003eMATelec Australia's HydroSTART Controller brings the features of the standard single and dual pump controllers into a new age with a redesigned capacitive touch keypad and control module with pump current sensing, providing wide range electronic overload protection which now functions with both single and three phase pumps.\u003c\/p\u003e\n\u003cp\u003eAdditional control inputs and functionality have been incorporated into the new design to enhance the controller's flexibility and cover an even wider range of pumping applications. The HydroSTART is the new standard for pump controls.\u003c\/p\u003e\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003ch4\u003eEnclosure\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eEnclosure size: 400x400x200mm\u003c\/li\u003e\n\u003cli\u003ePowder coated mild steel enclosure with removable gland plate\u003c\/li\u003e\n\u003cli\u003eIP56 rated with inner door for outdoor mounting (inner door version)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProtection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSelectable overload range: 0.1-6 Amp, 5-16 Amp\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003ePad-lockable mains power isolator switch\u003c\/li\u003e\n\u003cli\u003eLow voltage control and input circuitry\u003c\/li\u003e\n\u003cli\u003eIndividual pump circuit breaker protection\/isolation\u003c\/li\u003e\n\u003cli\u003eContactors for pump switching (three-phase panels)\u003c\/li\u003e\n\u003cli\u003eElectronic short and overload protection of alarms\u003c\/li\u003e\n\u003cli\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHydroSTART single or dual pump capacitive touch keypad interface:\n\u003cul\u003e\n\u003cli\u003eIndicator lights for system and pump status\u003c\/li\u003e\n\u003cli\u003eButtons for alarm mute\/reset and pump mode selection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eHydroSTART PCB control module with dipswitches for adjusting configuration\u003c\/li\u003e\n\u003cli\u003eVisual (strobe) and audible (buzzer) alarms\u003c\/li\u003e\n\u003cli\u003ePump current sensing providing adjustable overload \u0026amp; other protections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThree phase (400Vac) power supply \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eDigital input for thermostat and time clock\u003c\/li\u003e\n\u003cli\u003eHot water terminal set up, with volt free BMS outputs and system enable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOutputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e2x pump supply outputs\u003c\/li\u003e\n\u003cli\u003eBMS volt-free output for common fault\u003c\/li\u003e\n\u003cli\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/08f5a11902b64509503920491cac62bb60c5a92e.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/0fde2ce949a2d88c6cf6a1fee529c31b7451011f.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation Manual\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/2bd7c38a494e8c01cbfb4d1f1189308a61b1a103.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuick Start Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/85a2dcb6f7983bd6b95a1a57c28f6e6839cb322b.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"0.1-6amp","offer_id":45615456452717,"sku":"FPC-82243-HWC\/TC\/BMS-1","price":3057.12,"currency_code":"AUD","in_stock":true},{"title":"5-16 amp","offer_id":45615456485485,"sku":"FPC-82243-HWC\/TC\/BMS-2","price":3057.12,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPC-82243-ID-TC-BMS-Product.webp?v=1785473787"},{"product_id":"hydrowhiz-submersible-level-controller-3ph-2-pump-soft-starter-fpc-63243-s4-0-s90","title":"HydroWHIZ Submersible Level Controller (3PH 2 Pump Soft Starter) - FPC-63243-(S4.0-S22)","description":"\u003cp\u003eMATelec Australia's HydroWHIZ Submersible Level Controller is a premium multi-pump controller designed for advanced control of submersible pumping systems. Featuring a colour touchscreen HMI, HydroWHIZ PCB control module and flexible level, pressure and temperature control modes, it provides comprehensive pump control, monitoring and protection. This three-phase, two-pump version supports advanced functions including pump staging and destaging, duty sharing and alternation, staggered pump start and stop, pump limiting, data logging, trend graphs and diagnostic functions. The soft starter version is available with soft starter ratings from 4.0 kW to 90 kW.\u003c\/p\u003e\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003ch4\u003eEnclosure\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIP56 rated, powder-coated mild steel enclosure with inner door and removable gland plate\u003c\/li\u003e\n\u003cli\u003eEnclosure size: 400x400x250mm\u003c\/li\u003e\n\u003cli\u003eEnclosure size will increase for soft starter ratings and optional additions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProtection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003ePad-lockable mains power isolator switch\u003c\/li\u003e\n\u003cli\u003eCircuit breaker protected low voltage control and input circuitry\u003c\/li\u003e\n\u003cli\u003eIndividual pump isolation\u003c\/li\u003e\n\u003cli\u003eContactor protection of pump motors\u003c\/li\u003e\n\u003cli\u003eDin rail-mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHydroWHIZ colour touch screen HMI\u003c\/li\u003e\n\u003cli\u003eHydroWHIZ PCB control module\u003c\/li\u003e\n\u003cli\u003eVisual strobe and mutable audible buzzer alarms\u003c\/li\u003e\n\u003cli\u003eMain screen with system status and auto\/off\/manual modes\u003c\/li\u003e\n\u003cli\u003ePump screens with status, logged data and auto\/off\/manual control\u003c\/li\u003e\n\u003cli\u003eAlarm screens with mute\/reset and date and time-stamped historical faults\u003c\/li\u003e\n\u003cli\u003eLogged data including system event and fault counts, pump starts and run hours\u003c\/li\u003e\n\u003cli\u003eAnalogue feedback value trend graph\u003c\/li\u003e\n\u003cli\u003eSystem diagnostics and factory reset\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThree phase (400Vac) power supply\u003c\/li\u003e\n\u003cli\u003eAnalogue 4-20mA input for level, pressure or temperature transducer\u003c\/li\u003e\n\u003cli\u003eUp to 8x digital 24Vdc inputs for low, stop, start, standby start and high float switches, pressure switches or thermostats\u003c\/li\u003e\n\u003cli\u003eSystem enable\/disable input\u003c\/li\u003e\n\u003cli\u003eLow flow switch input\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eThermal switch inputs per pump\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOutputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e2 pump outputs\u003c\/li\u003e\n\u003cli\u003eBMS volt-free output for common fault\u003c\/li\u003e\n\u003cli\u003eAnalogue 0-10V output mirroring the analogue input\u003c\/li\u003e\n\u003cli\u003eOutput for solenoid valve available on request\u003c\/li\u003e\n\u003cli\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSoft Starter\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSoft starter control\u003c\/li\u003e\n\u003cli\u003eSoft starter rating: 4.0 kW to 90 kW\u003c\/li\u003e\n\u003cli\u003eSoft starter rating above 22 kw to 90kw prices will be available upon request.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFunction Features\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eControl of up to 6 pumps in duty, duty assist and standby configurations\u003c\/li\u003e\n\u003cli\u003ePump limiting for maximum flow or power requirements\u003c\/li\u003e\n\u003cli\u003eAdjustable duty sharing and alternation\u003c\/li\u003e\n\u003cli\u003ePump staging and destaging\u003c\/li\u003e\n\u003cli\u003eStaggered pump start and stop\u003c\/li\u003e\n\u003cli\u003eManual system and pump control with 10-minute timeout\u003c\/li\u003e\n\u003cli\u003eLevel, pressure or temperature control\u003c\/li\u003e\n\u003cli\u003eTank emptying or filling control\u003c\/li\u003e\n\u003cli\u003e4-20mA hydrostatic level transducer and float switch level control\u003c\/li\u003e\n\u003cli\u003eTank top-up valve control\u003c\/li\u003e\n\u003cli\u003eMaintain minimum level function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFault Protection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHigh and low level, pressure or temperature protection\u003c\/li\u003e\n\u003cli\u003eAuxiliary tank level protection\u003c\/li\u003e\n\u003cli\u003ePump anti-seize protection\u003c\/li\u003e\n\u003cli\u003eMaximum run protection\u003c\/li\u003e\n\u003cli\u003ePump cycle protection\u003c\/li\u003e\n\u003cli\u003eNo flow protection\u003c\/li\u003e\n\u003cli\u003eFeedback signal fault protection\u003c\/li\u003e\n\u003cli\u003ePump overload protection\u003c\/li\u003e\n\u003cli\u003ePump thermal switch protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommon Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWater Transfer\u003c\/li\u003e\n\u003cli\u003eTank Fill\u003c\/li\u003e\n\u003cli\u003eSewage Pump Out\u003c\/li\u003e\n\u003cli\u003eStormwater Pump Out\u003c\/li\u003e\n\u003cli\u003ePressure Boosting\u003c\/li\u003e\n\u003cli\u003eHot Water Recirculation\u003c\/li\u003e\n\u003cli\u003eChiller Supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"pdf-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/e54d9eba0e4ab3257a8d93c1c52aaa5a00c4f088.pdf\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"-S4.0 \/ 4.0 kW","offer_id":45597622304877,"sku":"FPC-63243-S4","price":7311.04,"currency_code":"AUD","in_stock":true},{"title":"-S5.5 \/ 5.5 kW","offer_id":45597622337645,"sku":"FPC-63243-S5.5","price":7866.32,"currency_code":"AUD","in_stock":true},{"title":"-S7.5 \/ 7.5 kW","offer_id":45597622370413,"sku":"FPC-63243-S7.5","price":7974.56,"currency_code":"AUD","in_stock":true},{"title":"-S11 \/ 11 kW","offer_id":45597622403181,"sku":"FPC-63243-S11","price":8528.08,"currency_code":"AUD","in_stock":true},{"title":"-S15 \/ 15 kW","offer_id":45597622435949,"sku":"FPC-63243-S15","price":8965.44,"currency_code":"AUD","in_stock":true},{"title":"-S22 \/ 22 kW","offer_id":45597622468717,"sku":"FPC-63243-S22","price":10028.48,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPC-63343-product.webp?v=1785397859"},{"product_id":"hydrowhiz-submersible-level-controller-3ph-3-pump-soft-starter-fpc-63343-s4-0-s90","title":"HydroWHIZ Submersible Level Controller (3PH 3 Pump Soft Starter) - FPC-63343-(S4.0-S22)","description":"\u003cp\u003eMATelec Australia's HydroWHIZ Submersible Level Controller is a premium multi-pump controller designed for advanced control of submersible pumping systems. Featuring a colour touchscreen HMI, HydroWHIZ PCB control module and flexible level, pressure and temperature control modes, it provides comprehensive pump control, monitoring and protection. This three-phase, three-pump version supports advanced functions including pump staging and destaging, duty sharing and alternation, staggered pump start and stop, pump limiting, data logging, trend graphs and diagnostic functions. The soft starter version is available with soft starter ratings from 4.0 kW to 90 kW.\u003c\/p\u003e\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003ch4\u003eEnclosure\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIP56 rated, powder-coated mild steel enclosure with inner door and removable gland plate\u003c\/li\u003e\n\u003cli\u003eEnclosure size: 400x400x250mm\u003c\/li\u003e\n\u003cli\u003eEnclosure size will increase for soft starter ratings and optional additions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProtection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003ePad-lockable mains power isolator switch\u003c\/li\u003e\n\u003cli\u003eCircuit breaker protected low voltage control and input circuitry\u003c\/li\u003e\n\u003cli\u003eIndividual pump isolation\u003c\/li\u003e\n\u003cli\u003eContactor protection of pump motors\u003c\/li\u003e\n\u003cli\u003eDin rail-mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHydroWHIZ colour touch screen HMI\u003c\/li\u003e\n\u003cli\u003eHydroWHIZ PCB control module\u003c\/li\u003e\n\u003cli\u003eVisual strobe and mutable audible buzzer alarms\u003c\/li\u003e\n\u003cli\u003eMain screen with system status and auto\/off\/manual modes\u003c\/li\u003e\n\u003cli\u003ePump screens with status, logged data and auto\/off\/manual control\u003c\/li\u003e\n\u003cli\u003eAlarm screens with mute\/reset and date and time-stamped historical faults\u003c\/li\u003e\n\u003cli\u003eLogged data including system event and fault counts, pump starts and run hours\u003c\/li\u003e\n\u003cli\u003eAnalogue feedback value trend graph\u003c\/li\u003e\n\u003cli\u003eSystem diagnostics and factory reset\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThree phase (400Vac) power supply\u003c\/li\u003e\n\u003cli\u003eAnalogue 4-20mA input for level, pressure or temperature transducer\u003c\/li\u003e\n\u003cli\u003eUp to 8x digital 24Vdc inputs for low, stop, start, standby start and high float switches, pressure switches or thermostats\u003c\/li\u003e\n\u003cli\u003eSystem enable\/disable input\u003c\/li\u003e\n\u003cli\u003eLow flow switch input\u003c\/li\u003e\n\u003cli\u003eThermal switch inputs per pump\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOutputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e3 pump outputs\u003c\/li\u003e\n\u003cli\u003eBMS volt-free output for common fault\u003c\/li\u003e\n\u003cli\u003eAnalogue 0-10V output mirroring the analogue input\u003c\/li\u003e\n\u003cli\u003eOutput for solenoid valve available on request\u003c\/li\u003e\n\u003cli\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSoft Starter\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSoft starter control\u003c\/li\u003e\n\u003cli\u003eSoft starter rating: 4.0 kW to 90 kW\u003c\/li\u003e\n\u003cli\u003eSoft starter rating above 22 kw to 90kw prices will be available upon request.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFunction Features\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eControl of up to 6 pumps in duty, duty assist and standby configurations\u003c\/li\u003e\n\u003cli\u003ePump limiting for maximum flow or power requirements\u003c\/li\u003e\n\u003cli\u003eAdjustable duty sharing and alternation\u003c\/li\u003e\n\u003cli\u003ePump staging and destaging\u003c\/li\u003e\n\u003cli\u003eStaggered pump start and stop\u003c\/li\u003e\n\u003cli\u003eManual system and pump control with 10-minute timeout\u003c\/li\u003e\n\u003cli\u003eLevel, pressure or temperature control\u003c\/li\u003e\n\u003cli\u003eTank emptying or filling control\u003c\/li\u003e\n\u003cli\u003e4-20mA hydrostatic level transducer and float switch level control\u003c\/li\u003e\n\u003cli\u003eTank top-up valve control\u003c\/li\u003e\n\u003cli\u003eMaintain minimum level function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFault Protection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHigh and low level, pressure or temperature protection\u003c\/li\u003e\n\u003cli\u003eAuxiliary tank level protection\u003c\/li\u003e\n\u003cli\u003ePump anti-seize protection\u003c\/li\u003e\n\u003cli\u003eMaximum run protection\u003c\/li\u003e\n\u003cli\u003ePump cycle protection\u003c\/li\u003e\n\u003cli\u003eNo flow protection\u003c\/li\u003e\n\u003cli\u003eFeedback signal fault protection\u003c\/li\u003e\n\u003cli\u003ePump overload protection\u003c\/li\u003e\n\u003cli\u003ePump thermal switch protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommon Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWater Transfer\u003c\/li\u003e\n\u003cli\u003eTank Fill\u003c\/li\u003e\n\u003cli\u003eSewage Pump Out\u003c\/li\u003e\n\u003cli\u003eStormwater Pump Out\u003c\/li\u003e\n\u003cli\u003ePressure Boosting\u003c\/li\u003e\n\u003cli\u003eHot Water Recirculation\u003c\/li\u003e\n\u003cli\u003eChiller Supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"pdf-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/e54d9eba0e4ab3257a8d93c1c52aaa5a00c4f088.pdf\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"-S4.0 \/ 4.0 kW","offer_id":45597630791789,"sku":"FPC-63343-S4","price":9850.72,"currency_code":"AUD","in_stock":true},{"title":"-S5.5 \/ 5.5 kW","offer_id":45597630824557,"sku":"FPC-63343-S5.5","price":10380.48,"currency_code":"AUD","in_stock":true},{"title":"-S7.5 \/ 7.5 kW","offer_id":45597630857325,"sku":"FPC-63343-S7.5","price":10936.64,"currency_code":"AUD","in_stock":true},{"title":"-S11 \/ 11 kW","offer_id":45597630890093,"sku":"FPC-63343-S11","price":12046.32,"currency_code":"AUD","in_stock":true},{"title":"-S15 \/ 15 kW","offer_id":45597630922861,"sku":"FPC-63343-S15","price":12874.4,"currency_code":"AUD","in_stock":true},{"title":"-S22 \/ 22 kW","offer_id":45597630955629,"sku":"FPC-63343-S22","price":16356.56,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPC-63343-product.webp?v=1785397859"},{"product_id":"hydrostart-hot-water-circulation-controller-3ph-1-pump-soft-starter-fpc-82143-s4-0-s90","title":"HydroSTART Submersible Level Controller (3PH 1 Pump Soft Starter) - FPC-82143-(S4.0-S90)","description":"\u003cp\u003eMATelec Australia's HydroSTART Controller brings the features of the standard single and dual pump controllers into a new age with a redesigned capacitive touch keypad and control module with pump current sensing, providing flexible pump control for both single and three phase pumps.\u003c\/p\u003e\n\u003cp\u003eAdditional control inputs and functionality have been incorporated into the new design to enhance the controller's flexibility and cover an even wider range of pumping applications. The HydroSTART is the new standard for pump controls.\u003c\/p\u003e\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003ch4\u003eEnclosure\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eEnclosure size: 400x400x200mm\u003c\/li\u003e\n\u003cli\u003eEnclosure size will increase for soft starter ratings and optional additions.\u003c\/li\u003e\n\u003cli\u003ePowder coated mild steel enclosure with removable gland plate\u003c\/li\u003e\n\u003cli\u003eIP56 rated with inner door for outdoor mounting (inner door version)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProtection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003ePad-lockable mains power isolator switch\u003c\/li\u003e\n\u003cli\u003eLow voltage control and input circuitry\u003c\/li\u003e\n\u003cli\u003eIndividual pump circuit breaker protection\/isolation\u003c\/li\u003e\n\u003cli\u003eContactors for pump switching (three-phase panels)\u003c\/li\u003e\n\u003cli\u003eElectronic short and overload protection of alarms\u003c\/li\u003e\n\u003cli\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHydroSTART single or dual pump capacitive touch keypad interface:\n\u003cul\u003e\n\u003cli\u003eIndicator lights for system and pump status\u003c\/li\u003e\n\u003cli\u003eButtons for alarm mute\/reset and pump mode selection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eHydroSTART PCB control module with dipswitches for adjusting configuration\u003c\/li\u003e\n\u003cli\u003eVisual (strobe) and audible (buzzer) alarms\u003c\/li\u003e\n\u003cli\u003eSoft starter per pump with adjustable soft start and soft stop\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThree phase (400Vac) power supply\u003c\/li\u003e\n\u003cli\u003eDigital input for thermostat and time clock\u003c\/li\u003e\n\u003cli\u003eHot water terminal set up, with volt free BMS outputs and system enable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOutputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e1x pump supply output\u003c\/li\u003e\n\u003cli\u003eBMS volt-free output for common fault\u003c\/li\u003e\n\u003cli\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSoft Starter Options\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSoft starter control\u003c\/li\u003e\n\u003cli\u003eSoft starter rating: 4.0 kW to 90 kW\u003c\/li\u003e\n\u003cli\u003eSoft starter rating above 55 kw to 90kw prices will be available upon request.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/08f5a11902b64509503920491cac62bb60c5a92e.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/0fde2ce949a2d88c6cf6a1fee529c31b7451011f.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation Manual\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/2bd7c38a494e8c01cbfb4d1f1189308a61b1a103.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuick Start Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/85a2dcb6f7983bd6b95a1a57c28f6e6839cb322b.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"-S4.0 \/ 4.0 kW","offer_id":45599013208173,"sku":"FPC-82143-S4","price":11234.96,"currency_code":"AUD","in_stock":true},{"title":"-S5.5 \/ 5.5 kW","offer_id":45599013240941,"sku":"FPC-82143-S5.5","price":4283.84,"currency_code":"AUD","in_stock":true},{"title":"-S7.5 \/ 7.5 kW","offer_id":45599013273709,"sku":"FPC-82143-S7.5","price":4402.64,"currency_code":"AUD","in_stock":true},{"title":"-S11 \/ 11 kW","offer_id":45599013306477,"sku":"FPC-82143-S11","price":5045.92,"currency_code":"AUD","in_stock":true},{"title":"-S15 \/ 15 kW","offer_id":45599013339245,"sku":"FPC-82143-S15","price":5323.12,"currency_code":"AUD","in_stock":true},{"title":"-S18.5 \/ 18.5 kW","offer_id":45626854113389,"sku":"FPC-82143-S18.5","price":5722.64,"currency_code":"AUD","in_stock":true},{"title":"-S22 \/ 22 kW","offer_id":45599013372013,"sku":"FPC-82143-S22","price":6369.44,"currency_code":"AUD","in_stock":true},{"title":"-S30 \/ 30 kW","offer_id":45599013404781,"sku":"FPC-82143-S30","price":9690.56,"currency_code":"AUD","in_stock":true},{"title":"-S37 \/ 37 kW","offer_id":45599013437549,"sku":"FPC-82143-S37","price":10829.28,"currency_code":"AUD","in_stock":true},{"title":"-S45 \/ 45 kW","offer_id":45599013470317,"sku":"FPC-82143-S45","price":11234.96,"currency_code":"AUD","in_stock":true},{"title":"-S55 \/ 55 kW","offer_id":45599013503085,"sku":"FPC-82143-S55","price":15475.68,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPC-82243-ID-product.webp?v=1785473370"},{"product_id":"hydrostart-hot-water-circulation-controller-3ph-2-pump-soft-starter-fpc-82243-s4-0-s90","title":"HydroSTART Submersible Level Controller (3PH 2 Pump Soft Starter) - FPC-82243-(S4.0-S90)","description":"\u003cp\u003eMATelec Australia's HydroSTART Controller brings the features of the standard single and dual pump controllers into a new age with a redesigned capacitive touch keypad and control module with pump current sensing, providing flexible pump control for both single and three phase pumps.\u003c\/p\u003e\n\u003cp\u003eAdditional control inputs and functionality have been incorporated into the new design to enhance the controller's flexibility and cover an even wider range of pumping applications. The HydroSTART is the new standard for pump controls.\u003c\/p\u003e\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003ch4\u003eEnclosure\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eEnclosure size: 400x400x200mm\u003c\/li\u003e\n\u003cli\u003eEnclosure size will increase for soft starter ratings and optional additions.\u003c\/li\u003e\n\u003cli\u003ePowder coated mild steel enclosure with removable gland plate\u003c\/li\u003e\n\u003cli\u003eIP56 rated with inner door for outdoor mounting (inner door version)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProtection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003ePad-lockable mains power isolator switch\u003c\/li\u003e\n\u003cli\u003eLow voltage control and input circuitry\u003c\/li\u003e\n\u003cli\u003eIndividual pump circuit breaker protection\/isolation\u003c\/li\u003e\n\u003cli\u003eContactors for pump switching (three-phase panels)\u003c\/li\u003e\n\u003cli\u003eElectronic short and overload protection of alarms\u003c\/li\u003e\n\u003cli\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHydroSTART single or dual pump capacitive touch keypad interface:\n\u003cul\u003e\n\u003cli\u003eIndicator lights for system and pump status\u003c\/li\u003e\n\u003cli\u003eButtons for alarm mute\/reset and pump mode selection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eHydroSTART PCB control module with dipswitches for adjusting configuration\u003c\/li\u003e\n\u003cli\u003eVisual (strobe) and audible (buzzer) alarms\u003c\/li\u003e\n\u003cli\u003eSoft starter per pump with adjustable soft start and soft stop\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThree phase (400Vac) power supply\u003c\/li\u003e\n\u003cli\u003eDigital input for thermostat and time clock\u003c\/li\u003e\n\u003cli\u003eHot water terminal set up, with volt free BMS outputs and system enable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOutputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e2x pump supply outputs\u003c\/li\u003e\n\u003cli\u003eBMS volt-free output for common fault\u003c\/li\u003e\n\u003cli\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSoft Starter Options\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSoft starter control\u003c\/li\u003e\n\u003cli\u003eSoft starter rating: 4.0 kW to 90 kW\u003c\/li\u003e\n\u003cli\u003eSoft starter rating above 37 kw to 90kw prices will be available upon request.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/08f5a11902b64509503920491cac62bb60c5a92e.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/0fde2ce949a2d88c6cf6a1fee529c31b7451011f.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation Manual\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/2bd7c38a494e8c01cbfb4d1f1189308a61b1a103.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuick Start Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/85a2dcb6f7983bd6b95a1a57c28f6e6839cb322b.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"-S4.0 \/ 4.0 kW","offer_id":45599015305325,"sku":"FPC-82243-S4","price":6122.16,"currency_code":"AUD","in_stock":true},{"title":"-S5.5 \/ 5.5 kW","offer_id":45599015338093,"sku":"FPC-82243-S5.5","price":6334.24,"currency_code":"AUD","in_stock":true},{"title":"-S7.5 \/ 7.5 kW","offer_id":45599015370861,"sku":"FPC-82243-S7.5","price":6599.12,"currency_code":"AUD","in_stock":true},{"title":"-S11 \/ 11 kW","offer_id":45599015403629,"sku":"FPC-82243-S11","price":7560.96,"currency_code":"AUD","in_stock":true},{"title":"-S15 \/ 15 kW","offer_id":45599015436397,"sku":"FPC-82243-S15","price":7976.32,"currency_code":"AUD","in_stock":true},{"title":"-S18.5 \/ 18.5 kW","offer_id":45626855882861,"sku":"FPC-82243-S18.5","price":8719.04,"currency_code":"AUD","in_stock":true},{"title":"-S22 \/ 22 kW","offer_id":45599015469165,"sku":"FPC-82243-S22","price":9541.84,"currency_code":"AUD","in_stock":true},{"title":"-S37 \/ 37 kW","offer_id":45599015534701,"sku":"FPC-82243-S37","price":19556.24,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPC-82243-ID-product.webp?v=1785473370"},{"product_id":"hydrostart-pro-submersible-pump-controller-1ph-2-pump-fpp-82241","title":"HydroSTART PRO Submersible Pump Controller (1PH 2 Pump) - FPP-82241","description":"\u003cp\u003eMATelec Australia’s HydroSTART PRO Controller is the flagship dual pump controller in the Australian Market. Designed for the professional, this controller features the highest quality enclosure, premium Schneider switchgear, intuitive capacitive touch keypad and Matelec Australia’s Market Leading HydroSTART Pro Control module.\u003c\/p\u003e\n\u003cp\u003eThe unit comes complete with pump current sensing and a wide range of electronic overload protection for both single and three phase pumps. A full suite of control inputs and functionality has been incorporated into the design to enhance the controller’s flexibility and cover an even wider range of pumping applications.\u003c\/p\u003e\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003ch4\u003eEnclosure\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eGrey powder coated galvanised mild steel IP66 with inner door\u003c\/li\u003e\n\u003cli\u003eEnclosure size: 400x400x200mm\u003c\/li\u003e\n\u003cli\u003eEnclosure size will increase for optional additions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProtection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eInner door mounted main isolator with door interlock\u003c\/li\u003e\n\u003cli\u003ePremium Schneider Circuit Breakers for individual pump protection\/isolation\u003c\/li\u003e\n\u003cli\u003eLow voltage control and input circuitry\u003c\/li\u003e\n\u003cli\u003ePremium Schneider Contactors for pump switching (three phase panels)\u003c\/li\u003e\n\u003cli\u003eElectronic short and overload protection of alarms\u003c\/li\u003e\n\u003cli\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHydroSTART dual pump capacitive touch keypad interface\u003c\/li\u003e\n\u003cli\u003eIndicator lights for system, pump and input status, level alarm\u003c\/li\u003e\n\u003cli\u003eButtons for alarm mute\/reset and pump mode selection\u003c\/li\u003e\n\u003cli\u003eHydroSTART PCB control module with dip-switches for adjusting configuration\u003c\/li\u003e\n\u003cli\u003eVisual (strobe) and audible (buzzer) alarms\u003c\/li\u003e\n\u003cli\u003ePump current sensing providing adjustable overload \u0026amp; other protections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSingle phase (230Vac) power supply\u003c\/li\u003e\n\u003cli\u003e6x digital inputs for float or pressure switches, optional prime loss flow switch and system enable\u003c\/li\u003e\n\u003cli\u003eStandard terminal setup: Low level, duty stop, duty start, standby start, high level and system enable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOutputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e2 pump supply outputs\u003c\/li\u003e\n\u003cli\u003eBMS volt free output for common fault\u003c\/li\u003e\n\u003cli\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFunctions\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eLevel control mode – Level empty operation controlled by up to 5 float switches\u003c\/li\u003e\n\u003cli\u003ePressure control mode – Pressure boost operation controlled by up to 3 pressure switches\u003c\/li\u003e\n\u003cli\u003eDuty sharing and alternation – Alternates on pump start and after set run times\u003c\/li\u003e\n\u003cli\u003eStaggered pump start – Prevents excessive current draw and reduces water surge\u003c\/li\u003e\n\u003cli\u003eManual pump control – Manual mode with optional timeout\u003c\/li\u003e\n\u003cli\u003eSystem enable input – Enables\/disables system in auto mode\u003c\/li\u003e\n\u003cli\u003eStatic duty mode – No duty alternation\u003c\/li\u003e\n\u003cli\u003eSmart chirp mode alarms – Audible alarm silences after 5 minutes, chirps every 5 minutes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFault Protection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHigh level alarm – Delayed alarm with auto\/manual reset depending on mode\u003c\/li\u003e\n\u003cli\u003eLow level protection – Shuts down pumps, manual reset only\u003c\/li\u003e\n\u003cli\u003eLow pressure protection – Shuts down pumps if input closed for 60 seconds\u003c\/li\u003e\n\u003cli\u003ePrime loss protection – Shuts down pumps if no flow for 30 seconds\u003c\/li\u003e\n\u003cli\u003ePump anti-seize protection – Runs pumps periodically during low use\u003c\/li\u003e\n\u003cli\u003ePump current sensing – Adjustable overload, undercurrent and zero current protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/49bb51d56250b36b65102dad6bfc116f753bea7e.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomation and Control Product Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/0fde2ce949a2d88c6cf6a1fee529c31b7451011f.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"Default Title","offer_id":45599596937325,"sku":"FPP-82241","price":3631.76,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPP-82241-PC-premium-polycarbonate-product.webp?v=1786437961"},{"product_id":"hydrostart-pro-submersible-pump-controller-1ph-2-pump-fpp-82241-pc","title":"HydroSTART PRO Submersible Pump Controller (1PH 2 Pump) - FPP-82241-PC","description":"\u003cp\u003eMATelec Australia’s HydroSTART PRO Controller is the flagship dual pump controller in the Australian Market. Designed for the professional, this controller features the highest quality enclosure, premium Schneider switchgear, intuitive capacitive touch keypad and Matelec Australia’s Market Leading HydroSTART Pro Control module.\u003c\/p\u003e\n\u003cp\u003eThe unit comes complete with pump current sensing and a wide range of electronic overload protection for both single and three phase pumps. A full suite of control inputs and functionality has been incorporated into the design to enhance the controller’s flexibility and cover an even wider range of pumping applications.\u003c\/p\u003e\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003ch4\u003eEnclosure\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003ePremium polycarbonate IP66 with inner door\u003c\/li\u003e\n\u003cli\u003eEnclosure size: 400x400x200mm\u003c\/li\u003e\n\u003cli\u003eEnclosure size will increase for optional additions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProtection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eInner door mounted main isolator with door interlock\u003c\/li\u003e\n\u003cli\u003ePremium Schneider Circuit Breakers for individual pump protection\/isolation\u003c\/li\u003e\n\u003cli\u003eLow voltage control and input circuitry\u003c\/li\u003e\n\u003cli\u003ePremium Schneider Contactors for pump switching (three phase panels)\u003c\/li\u003e\n\u003cli\u003eElectronic short and overload protection of alarms\u003c\/li\u003e\n\u003cli\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHydroSTART dual pump capacitive touch keypad interface\u003c\/li\u003e\n\u003cli\u003eIndicator lights for system, pump and input status, level alarm\u003c\/li\u003e\n\u003cli\u003eButtons for alarm mute\/reset and pump mode selection\u003c\/li\u003e\n\u003cli\u003eHydroSTART PCB control module with dip-switches for adjusting configuration\u003c\/li\u003e\n\u003cli\u003eVisual (strobe) and audible (buzzer) alarms\u003c\/li\u003e\n\u003cli\u003ePump current sensing providing adjustable overload \u0026amp; other protections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSingle phase (230Vac) power supply\u003c\/li\u003e\n\u003cli\u003e6x digital inputs for float or pressure switches, optional prime loss flow switch and system enable\u003c\/li\u003e\n\u003cli\u003eStandard terminal setup: Low level, duty stop, duty start, standby start, high level and system enable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOutputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e2 pump supply outputs\u003c\/li\u003e\n\u003cli\u003eBMS volt free output for common fault\u003c\/li\u003e\n\u003cli\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFunctions\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eLevel control mode – Level empty operation controlled by up to 5 float switches\u003c\/li\u003e\n\u003cli\u003ePressure control mode – Pressure boost operation controlled by up to 3 pressure switches\u003c\/li\u003e\n\u003cli\u003eDuty sharing and alternation – Alternates on pump start and after set run times\u003c\/li\u003e\n\u003cli\u003eStaggered pump start – Prevents excessive current draw and reduces water surge\u003c\/li\u003e\n\u003cli\u003eManual pump control – Manual mode with optional timeout\u003c\/li\u003e\n\u003cli\u003eSystem enable input – Enables\/disables system in auto mode\u003c\/li\u003e\n\u003cli\u003eStatic duty mode – No duty alternation\u003c\/li\u003e\n\u003cli\u003eSmart chirp mode alarms – Audible alarm silences after 5 minutes, chirps every 5 minutes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFault Protection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHigh level alarm – Delayed alarm with auto\/manual reset depending on mode\u003c\/li\u003e\n\u003cli\u003eLow level protection – Shuts down pumps, manual reset only\u003c\/li\u003e\n\u003cli\u003eLow pressure protection – Shuts down pumps if input closed for 60 seconds\u003c\/li\u003e\n\u003cli\u003ePrime loss protection – Shuts down pumps if no flow for 30 seconds\u003c\/li\u003e\n\u003cli\u003ePump anti-seize protection – Runs pumps periodically during low use\u003c\/li\u003e\n\u003cli\u003ePump current sensing – Adjustable overload, undercurrent and zero current protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/49bb51d56250b36b65102dad6bfc116f753bea7e.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomation and Control Product Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/0fde2ce949a2d88c6cf6a1fee529c31b7451011f.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"Default Title","offer_id":45599612076141,"sku":"FPP-82241-PC","price":4478.32,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPP-82241-PC-premium-polycarbonate-product.webp?v=1786437961"},{"product_id":"hydrostart-pro-submersible-pump-controller-1ph-2-pump-fpp-82241-ss","title":"HydroSTART PRO Submersible Pump Controller (1PH 2 Pump) - FPP-82241-SS","description":"\u003cp\u003eMATelec Australia’s HydroSTART PRO Controller is the flagship dual pump controller in the Australian Market. Designed for the professional, this controller features the highest quality enclosure, premium Schneider switchgear, intuitive capacitive touch keypad and Matelec Australia’s Market Leading HydroSTART Pro Control module.\u003c\/p\u003e\n\u003cp\u003eThe unit comes complete with pump current sensing and a wide range of electronic overload protection for both single and three phase pumps. A full suite of control inputs and functionality has been incorporated into the design to enhance the controller’s flexibility and cover an even wider range of pumping applications.\u003c\/p\u003e\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003ch4\u003eEnclosure Options\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003ePremium powder coated 316 stainless steel, IP66 with inner door\u003c\/li\u003e\n\u003cli\u003eEnclosure size: 400x400x200mm\u003c\/li\u003e\n\u003cli\u003eEnclosure size will increase for optional additions.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProtection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eInner door mounted main isolator with door interlock\u003c\/li\u003e\n\u003cli\u003ePremium Schneider Circuit Breakers for individual pump protection\/isolation\u003c\/li\u003e\n\u003cli\u003eLow voltage control and input circuitry\u003c\/li\u003e\n\u003cli\u003ePremium Schneider Contactors for pump switching (three phase panels)\u003c\/li\u003e\n\u003cli\u003eElectronic short and overload protection of alarms\u003c\/li\u003e\n\u003cli\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHydroSTART dual pump capacitive touch keypad interface\u003c\/li\u003e\n\u003cli\u003eIndicator lights for system, pump and input status, level alarm\u003c\/li\u003e\n\u003cli\u003eButtons for alarm mute\/reset and pump mode selection\u003c\/li\u003e\n\u003cli\u003eHydroSTART PCB control module with dip-switches for adjusting configuration\u003c\/li\u003e\n\u003cli\u003eVisual (strobe) and audible (buzzer) alarms\u003c\/li\u003e\n\u003cli\u003ePump current sensing providing adjustable overload \u0026amp; other protections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSingle phase (230Vac) power supply\u003c\/li\u003e\n\u003cli\u003e6x digital inputs for float or pressure switches, optional prime loss flow switch and system enable\u003c\/li\u003e\n\u003cli\u003eStandard terminal setup: Low level, duty stop, duty start, standby start, high level and system enable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOutputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e2 pump supply outputs\u003c\/li\u003e\n\u003cli\u003eBMS volt free output for common fault\u003c\/li\u003e\n\u003cli\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFunctions\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eLevel control mode – Level empty operation controlled by up to 5 float switches\u003c\/li\u003e\n\u003cli\u003ePressure control mode – Pressure boost operation controlled by up to 3 pressure switches\u003c\/li\u003e\n\u003cli\u003eDuty sharing and alternation – Alternates on pump start and after set run times\u003c\/li\u003e\n\u003cli\u003eStaggered pump start – Prevents excessive current draw and reduces water surge\u003c\/li\u003e\n\u003cli\u003eManual pump control – Manual mode with optional timeout\u003c\/li\u003e\n\u003cli\u003eSystem enable input – Enables\/disables system in auto mode\u003c\/li\u003e\n\u003cli\u003eStatic duty mode – No duty alternation\u003c\/li\u003e\n\u003cli\u003eSmart chirp mode alarms – Audible alarm silences after 5 minutes, chirps every 5 minutes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFault Protection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHigh level alarm – Delayed alarm with auto\/manual reset depending on mode\u003c\/li\u003e\n\u003cli\u003eLow level protection – Shuts down pumps, manual reset only\u003c\/li\u003e\n\u003cli\u003eLow pressure protection – Shuts down pumps if input closed for 60 seconds\u003c\/li\u003e\n\u003cli\u003ePrime loss protection – Shuts down pumps if no flow for 30 seconds\u003c\/li\u003e\n\u003cli\u003ePump anti-seize protection – Runs pumps periodically during low use\u003c\/li\u003e\n\u003cli\u003ePump current sensing – Adjustable overload, undercurrent and zero current protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/49bb51d56250b36b65102dad6bfc116f753bea7e.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomation and Control Product Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/0fde2ce949a2d88c6cf6a1fee529c31b7451011f.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"Default Title","offer_id":45599629639789,"sku":"FPP-82241-SS","price":3828.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPP-82241-SS-premium-polycarbonate-product.webp?v=1786438773"},{"product_id":"hydrostart-pro-submersible-pump-controller-1ph-2-pump-fpp-82241-x15","title":"HydroSTART PRO Submersible Pump Controller (1PH 2 Pump) - FPP-82241-X15","description":"\u003cp\u003eMATelec Australia’s HydroSTART PRO Controller is the flagship dual pump controller in the Australian Market. Designed for the professional, this controller features the highest quality enclosure, premium Schneider switchgear, intuitive capacitive touch keypad and Matelec Australia’s Market Leading HydroSTART Pro Control module.\u003c\/p\u003e\n\u003cp\u003eThe unit comes complete with pump current sensing and a wide range of electronic overload protection for both single and three phase pumps. A full suite of control inputs and functionality has been incorporated into the design to enhance the controller’s flexibility and cover an even wider range of pumping applications.\u003c\/p\u003e\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003ch4\u003eEnclosure Options\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eX15 orange powder coated galvanised mild steel, IP66 with inner door\u003c\/li\u003e\n\u003cli\u003eEnclosure size: 400x400x200mm\u003c\/li\u003e\n\u003cli\u003eEnclosure size will increase for optional additions.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProtection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eInner door mounted main isolator with door interlock\u003c\/li\u003e\n\u003cli\u003ePremium Schneider Circuit Breakers for individual pump protection\/isolation\u003c\/li\u003e\n\u003cli\u003eLow voltage control and input circuitry\u003c\/li\u003e\n\u003cli\u003ePremium Schneider Contactors for pump switching (three phase panels)\u003c\/li\u003e\n\u003cli\u003eElectronic short and overload protection of alarms\u003c\/li\u003e\n\u003cli\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHydroSTART dual pump capacitive touch keypad interface\u003c\/li\u003e\n\u003cli\u003eIndicator lights for system, pump and input status, level alarm\u003c\/li\u003e\n\u003cli\u003eButtons for alarm mute\/reset and pump mode selection\u003c\/li\u003e\n\u003cli\u003eHydroSTART PCB control module with dip-switches for adjusting configuration\u003c\/li\u003e\n\u003cli\u003eVisual (strobe) and audible (buzzer) alarms\u003c\/li\u003e\n\u003cli\u003ePump current sensing providing adjustable overload \u0026amp; other protections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSingle phase (230Vac) power supply\u003c\/li\u003e\n\u003cli\u003e6x digital inputs for float or pressure switches, optional prime loss flow switch and system enable\u003c\/li\u003e\n\u003cli\u003eStandard terminal setup: Low level, duty stop, duty start, standby start, high level and system enable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOutputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e2 pump supply outputs\u003c\/li\u003e\n\u003cli\u003eBMS volt free output for common fault\u003c\/li\u003e\n\u003cli\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFunctions\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eLevel control mode – Level empty operation controlled by up to 5 float switches\u003c\/li\u003e\n\u003cli\u003ePressure control mode – Pressure boost operation controlled by up to 3 pressure switches\u003c\/li\u003e\n\u003cli\u003eDuty sharing and alternation – Alternates on pump start and after set run times\u003c\/li\u003e\n\u003cli\u003eStaggered pump start – Prevents excessive current draw and reduces water surge\u003c\/li\u003e\n\u003cli\u003eManual pump control – Manual mode with optional timeout\u003c\/li\u003e\n\u003cli\u003eSystem enable input – Enables\/disables system in auto mode\u003c\/li\u003e\n\u003cli\u003eStatic duty mode – No duty alternation\u003c\/li\u003e\n\u003cli\u003eSmart chirp mode alarms – Audible alarm silences after 5 minutes, chirps every 5 minutes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFault Protection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHigh level alarm – Delayed alarm with auto\/manual reset depending on mode\u003c\/li\u003e\n\u003cli\u003eLow level protection – Shuts down pumps, manual reset only\u003c\/li\u003e\n\u003cli\u003eLow pressure protection – Shuts down pumps if input closed for 60 seconds\u003c\/li\u003e\n\u003cli\u003ePrime loss protection – Shuts down pumps if no flow for 30 seconds\u003c\/li\u003e\n\u003cli\u003ePump anti-seize protection – Runs pumps periodically during low use\u003c\/li\u003e\n\u003cli\u003ePump current sensing – Adjustable overload, undercurrent and zero current protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/49bb51d56250b36b65102dad6bfc116f753bea7e.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomation and Control Product Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/0fde2ce949a2d88c6cf6a1fee529c31b7451011f.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"Default Title","offer_id":45599637930093,"sku":"FPP-82241-X15","price":4123.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPP-82241-X15-product.webp?v=1786439061"},{"product_id":"hydrostart-pro-submersible-pump-controller-3ph-2-pump-fpp-82243","title":"HydroSTART PRO Submersible Pump Controller (3PH 2 Pump) - FPP-82243","description":"\u003cp bis_size='{\"x\":12,\"y\":9,\"w\":565,\"h\":78,\"abs_x\":618,\"abs_y\":270}'\u003eMATelec Australia’s HydroSTART PRO Controller is the flagship dual pump controller in the Australian Market. Designed for the professional, this controller features the highest quality enclosure, premium Schneider switchgear, intuitive capacitive touch keypad and Matelec Australia’s Market Leading HydroSTART Pro Control module.\u003c\/p\u003e\n\u003cp bis_size='{\"x\":12,\"y\":103,\"w\":565,\"h\":78,\"abs_x\":618,\"abs_y\":364}'\u003eThe unit comes complete with pump current sensing and a wide range of electronic overload protection for both single and three phase pumps. A full suite of control inputs and functionality has been incorporated into the design to enhance the controller’s flexibility and cover an even wider range of pumping applications.\u003c\/p\u003e\n\u003ch3 bis_size='{\"x\":12,\"y\":198,\"w\":565,\"h\":22,\"abs_x\":618,\"abs_y\":459}'\u003eProduct Details\u003c\/h3\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":231,\"w\":565,\"h\":19,\"abs_x\":618,\"abs_y\":492}'\u003eEnclosure Options\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":265,\"w\":565,\"h\":58,\"abs_x\":618,\"abs_y\":526}'\u003e\n\u003cli\u003eGrey powder coated galvanised mild steel IP66 with inner door\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":285,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":546}'\u003eEnclosure size: 400x400x200mm\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":304,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":565}'\u003eEnclosure size will increase for optional additions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":338,\"w\":565,\"h\":19,\"abs_x\":618,\"abs_y\":599}'\u003eProtection\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":371,\"w\":565,\"h\":117,\"abs_x\":618,\"abs_y\":632}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":371,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":632}'\u003eInner door mounted main isolator with door interlock\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":391,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":652}'\u003ePremium Schneider Circuit Breakers for individual pump protection\/isolation\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":410,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":671}'\u003eLow voltage control and input circuitry\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":430,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":691}'\u003ePremium Schneider Contactors for pump switching (three phase panels)\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":450,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":711}'\u003eElectronic short and overload protection of alarms\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":469,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":730}'\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":503,\"w\":565,\"h\":19,\"abs_x\":618,\"abs_y\":764}'\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":536,\"w\":565,\"h\":117,\"abs_x\":618,\"abs_y\":797}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":536,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":797}'\u003eHydroSTART dual pump capacitive touch keypad interface\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":556,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":817}'\u003eIndicator lights for system, pump and input status, level alarm\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":576,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":837}'\u003eButtons for alarm mute\/reset and pump mode selection\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":595,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":856}'\u003eHydroSTART PCB control module with dip-switches for adjusting configuration\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":615,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":876}'\u003eVisual (strobe) and audible (buzzer) alarms\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":634,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":895}'\u003ePump current sensing providing adjustable overload \u0026amp; other protections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":668,\"w\":565,\"h\":19,\"abs_x\":618,\"abs_y\":929}'\u003eInputs\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":702,\"w\":565,\"h\":97,\"abs_x\":618,\"abs_y\":963}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":702,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":963}'\u003ethree phase (400Vac) power supply\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":721,\"w\":525,\"h\":39,\"abs_x\":658,\"abs_y\":982}'\u003e6x digital inputs for float or pressure switches, optional prime loss flow switch and system enable\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":760,\"w\":525,\"h\":39,\"abs_x\":658,\"abs_y\":1021}'\u003eStandard terminal setup: Low level, duty stop, duty start, standby start, high level and system enable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":814,\"w\":565,\"h\":19,\"abs_x\":618,\"abs_y\":1075}'\u003eOutputs\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":847,\"w\":565,\"h\":58,\"abs_x\":618,\"abs_y\":1108}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":847,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":1108}'\u003e2x pump supply outputs\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":867,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":1128}'\u003eBMS volt free output for common fault\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":886,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":1147}'\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":920,\"w\":565,\"h\":19,\"abs_x\":618,\"abs_y\":1181}'\u003eFunctions\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":954,\"w\":565,\"h\":195,\"abs_x\":618,\"abs_y\":1215}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":954,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":1215}'\u003eLevel control mode – Level empty operation controlled by up to 5 float switches\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":973,\"w\":525,\"h\":39,\"abs_x\":658,\"abs_y\":1234}'\u003ePressure control mode – Pressure boost operation controlled by up to 3 pressure switches\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1012,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":1273}'\u003eDuty sharing and alternation – Alternates on pump start and after set run times\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1032,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":1293}'\u003eStaggered pump start – Prevents excessive current draw and reduces water surge\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1052,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":1313}'\u003eManual pump control – Manual mode with optional timeout\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1071,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":1332}'\u003eSystem enable input – Enables\/disables system in auto mode\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1091,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":1352}'\u003eStatic duty mode – No duty alternation\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1110,\"w\":525,\"h\":39,\"abs_x\":658,\"abs_y\":1371}'\u003eSmart chirp mode alarms – Audible alarm silences after 5 minutes, chirps every 5 minutes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":1163,\"w\":565,\"h\":19,\"abs_x\":618,\"abs_y\":1424}'\u003eFault Protection\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":1197,\"w\":565,\"h\":137,\"abs_x\":618,\"abs_y\":1458}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1197,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":1458}'\u003eHigh level alarm – Delayed alarm with auto\/manual reset depending on mode\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1217,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":1478}'\u003eLow level protection – Shuts down pumps, manual reset only\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1236,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":1497}'\u003eLow pressure protection – Shuts down pumps if input closed for 60 seconds\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1256,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":1517}'\u003ePrime loss protection – Shuts down pumps if no flow for 30 seconds\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1275,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":1536}'\u003ePump anti-seize protection – Runs pumps periodically during low use\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1295,\"w\":525,\"h\":39,\"abs_x\":658,\"abs_y\":1556}'\u003ePump current sensing – Adjustable overload, undercurrent and zero current protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 bis_size='{\"x\":12,\"y\":1348,\"w\":565,\"h\":22,\"abs_x\":618,\"abs_y\":1609}'\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\" bis_size='{\"x\":12,\"y\":1382,\"w\":565,\"h\":55,\"abs_x\":618,\"abs_y\":1643}'\u003e\n\u003ctbody bis_size='{\"x\":15,\"y\":1385,\"w\":559,\"h\":49,\"abs_x\":621,\"abs_y\":1646}'\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":1385,\"w\":559,\"h\":23,\"abs_x\":621,\"abs_y\":1646}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":1385,\"w\":438,\"h\":23,\"abs_x\":621,\"abs_y\":1646}'\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":455,\"y\":1385,\"w\":119,\"h\":23,\"abs_x\":1061,\"abs_y\":1646}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/49bb51d56250b36b65102dad6bfc116f753bea7e.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":457,\"y\":1387,\"w\":63,\"h\":19,\"abs_x\":1063,\"abs_y\":1648}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":1410,\"w\":559,\"h\":23,\"abs_x\":621,\"abs_y\":1671}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":1410,\"w\":438,\"h\":23,\"abs_x\":621,\"abs_y\":1671}'\u003eAutomation and Control Product Guide\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":455,\"y\":1410,\"w\":119,\"h\":23,\"abs_x\":1061,\"abs_y\":1671}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/0fde2ce949a2d88c6cf6a1fee529c31b7451011f.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":457,\"y\":1412,\"w\":63,\"h\":19,\"abs_x\":1063,\"abs_y\":1673}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"Default Title","offer_id":45617222746221,"sku":"FPP-82243","price":4114.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPP-82243-PC-premium-polycarbonate-product.webp?v=1786603805"},{"product_id":"hydrostart-pro-submersible-pump-controller-3ph-2-pump-fpp-82243-pc","title":"HydroSTART PRO Submersible Pump Controller (3PH 2 Pump) - FPP-82243-PC","description":"\u003cp\u003eMATelec Australia’s HydroSTART PRO Controller is the flagship dual pump controller in the Australian Market. Designed for the professional, this controller features the highest quality enclosure, premium Schneider switchgear, intuitive capacitive touch keypad and Matelec Australia’s Market Leading HydroSTART Pro Control module.\u003c\/p\u003e\n\u003cp\u003eThe unit comes complete with pump current sensing and a wide range of electronic overload protection for both single and three phase pumps. A full suite of control inputs and functionality has been incorporated into the design to enhance the controller’s flexibility and cover an even wider range of pumping applications.\u003c\/p\u003e\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003ch4\u003eEnclosure Options\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003ePremium powder coated 316 stainless steel, IP66 with inner door\u003c\/li\u003e\n\u003cli\u003eEnclosure size: 400x400x200mm\u003c\/li\u003e\n\u003cli\u003eEnclosure size will increase for optional additions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProtection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eInner door mounted main isolator with door interlock\u003c\/li\u003e\n\u003cli\u003ePremium Schneider Circuit Breakers for individual pump protection\/isolation\u003c\/li\u003e\n\u003cli\u003eLow voltage control and input circuitry\u003c\/li\u003e\n\u003cli\u003ePremium Schneider Contactors for pump switching (three phase panels)\u003c\/li\u003e\n\u003cli\u003eElectronic short and overload protection of alarms\u003c\/li\u003e\n\u003cli\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHydroSTART dual pump capacitive touch keypad interface\u003c\/li\u003e\n\u003cli\u003eIndicator lights for system, pump and input status, level alarm\u003c\/li\u003e\n\u003cli\u003eButtons for alarm mute\/reset and pump mode selection\u003c\/li\u003e\n\u003cli\u003eHydroSTART PCB control module with dip-switches for adjusting configuration\u003c\/li\u003e\n\u003cli\u003eVisual (strobe) and audible (buzzer) alarms\u003c\/li\u003e\n\u003cli\u003ePump current sensing providing adjustable overload \u0026amp; other protections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003ethree phase (400Vac) power supply\u003c\/li\u003e\n\u003cli\u003e6x digital inputs for float or pressure switches, optional prime loss flow switch and system enable\u003c\/li\u003e\n\u003cli\u003eStandard terminal setup: Low level, duty stop, duty start, standby start, high level and system enable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOutputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e2x pump supply outputs\u003c\/li\u003e\n\u003cli\u003eBMS volt free output for common fault\u003c\/li\u003e\n\u003cli\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFunctions\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eLevel control mode – Level empty operation controlled by up to 5 float switches\u003c\/li\u003e\n\u003cli\u003ePressure control mode – Pressure boost operation controlled by up to 3 pressure switches\u003c\/li\u003e\n\u003cli\u003eDuty sharing and alternation – Alternates on pump start and after set run times\u003c\/li\u003e\n\u003cli\u003eStaggered pump start – Prevents excessive current draw and reduces water surge\u003c\/li\u003e\n\u003cli\u003eManual pump control – Manual mode with optional timeout\u003c\/li\u003e\n\u003cli\u003eSystem enable input – Enables\/disables system in auto mode\u003c\/li\u003e\n\u003cli\u003eStatic duty mode – No duty alternation\u003c\/li\u003e\n\u003cli\u003eSmart chirp mode alarms – Audible alarm silences after 5 minutes, chirps every 5 minutes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFault Protection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHigh level alarm – Delayed alarm with auto\/manual reset depending on mode\u003c\/li\u003e\n\u003cli\u003eLow level protection – Shuts down pumps, manual reset only\u003c\/li\u003e\n\u003cli\u003eLow pressure protection – Shuts down pumps if input closed for 60 seconds\u003c\/li\u003e\n\u003cli\u003ePrime loss protection – Shuts down pumps if no flow for 30 seconds\u003c\/li\u003e\n\u003cli\u003ePump anti-seize protection – Runs pumps periodically during low use\u003c\/li\u003e\n\u003cli\u003ePump current sensing – Adjustable overload, undercurrent and zero current protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/49bb51d56250b36b65102dad6bfc116f753bea7e.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomation and Control Product Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/0fde2ce949a2d88c6cf6a1fee529c31b7451011f.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"Default Title","offer_id":45617263444077,"sku":"FPP-82243-PC","price":5162.08,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPP-82243-PC-premium-polycarbonate-product.webp?v=1786603805"},{"product_id":"hydrostart-pro-submersible-pump-controller-3ph-2-pump-fpp-82243-ss","title":"HydroSTART PRO Submersible Pump Controller (3PH 2 Pump) - FPP-82243-SS","description":"\u003cp\u003eMATelec Australia’s HydroSTART PRO Controller is the flagship dual pump controller in the Australian Market. Designed for the professional, this controller features the highest quality enclosure, premium Schneider switchgear, intuitive capacitive touch keypad and Matelec Australia’s Market Leading HydroSTART Pro Control module.\u003c\/p\u003e\n\u003cp\u003eThe unit comes complete with pump current sensing and a wide range of electronic overload protection for both single and three phase pumps. A full suite of control inputs and functionality has been incorporated into the design to enhance the controller’s flexibility and cover an even wider range of pumping applications.\u003c\/p\u003e\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003ch4\u003eEnclosure Options\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003ePremium powder coated 316 stainless steel, IP66 with inner door\u003c\/li\u003e\n\u003cli\u003eEnclosure size: 400x400x200mm\u003c\/li\u003e\n\u003cli\u003eEnclosure size will increase for optional additions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProtection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eInner door mounted main isolator with door interlock\u003c\/li\u003e\n\u003cli\u003ePremium Schneider Circuit Breakers for individual pump protection\/isolation\u003c\/li\u003e\n\u003cli\u003eLow voltage control and input circuitry\u003c\/li\u003e\n\u003cli\u003ePremium Schneider Contactors for pump switching (three phase panels)\u003c\/li\u003e\n\u003cli\u003eElectronic short and overload protection of alarms\u003c\/li\u003e\n\u003cli\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHydroSTART dual pump capacitive touch keypad interface\u003c\/li\u003e\n\u003cli\u003eIndicator lights for system, pump and input status, level alarm\u003c\/li\u003e\n\u003cli\u003eButtons for alarm mute\/reset and pump mode selection\u003c\/li\u003e\n\u003cli\u003eHydroSTART PCB control module with dip-switches for adjusting configuration\u003c\/li\u003e\n\u003cli\u003eVisual (strobe) and audible (buzzer) alarms\u003c\/li\u003e\n\u003cli\u003ePump current sensing providing adjustable overload \u0026amp; other protections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003ethree phase (400Vac) power supply\u003c\/li\u003e\n\u003cli\u003e6x digital inputs for float or pressure switches, optional prime loss flow switch and system enable\u003c\/li\u003e\n\u003cli\u003eStandard terminal setup: Low level, duty stop, duty start, standby start, high level and system enable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOutputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e2x pump supply outputs\u003c\/li\u003e\n\u003cli\u003eBMS volt free output for common fault\u003c\/li\u003e\n\u003cli\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFunctions\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eLevel control mode – Level empty operation controlled by up to 5 float switches\u003c\/li\u003e\n\u003cli\u003ePressure control mode – Pressure boost operation controlled by up to 3 pressure switches\u003c\/li\u003e\n\u003cli\u003eDuty sharing and alternation – Alternates on pump start and after set run times\u003c\/li\u003e\n\u003cli\u003eStaggered pump start – Prevents excessive current draw and reduces water surge\u003c\/li\u003e\n\u003cli\u003eManual pump control – Manual mode with optional timeout\u003c\/li\u003e\n\u003cli\u003eSystem enable input – Enables\/disables system in auto mode\u003c\/li\u003e\n\u003cli\u003eStatic duty mode – No duty alternation\u003c\/li\u003e\n\u003cli\u003eSmart chirp mode alarms – Audible alarm silences after 5 minutes, chirps every 5 minutes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFault Protection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHigh level alarm – Delayed alarm with auto\/manual reset depending on mode\u003c\/li\u003e\n\u003cli\u003eLow level protection – Shuts down pumps, manual reset only\u003c\/li\u003e\n\u003cli\u003eLow pressure protection – Shuts down pumps if input closed for 60 seconds\u003c\/li\u003e\n\u003cli\u003ePrime loss protection – Shuts down pumps if no flow for 30 seconds\u003c\/li\u003e\n\u003cli\u003ePump anti-seize protection – Runs pumps periodically during low use\u003c\/li\u003e\n\u003cli\u003ePump current sensing – Adjustable overload, undercurrent and zero current protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/49bb51d56250b36b65102dad6bfc116f753bea7e.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomation and Control Product Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/0fde2ce949a2d88c6cf6a1fee529c31b7451011f.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"Default Title","offer_id":45617294147693,"sku":"FPP-82243-SS","price":5309.92,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPP-82243-SS-premium-polycarbonate-product.webp?v=1786604273"},{"product_id":"hydrostart-pro-submersible-pump-controller-3ph-2-pump-fpp-82243-x15","title":"HydroSTART PRO Submersible Pump Controller (3PH 2 Pump) - FPP-82243-X15","description":"\u003cp\u003eMATelec Australia’s HydroSTART PRO Controller is the flagship dual pump controller in the Australian Market. Designed for the professional, this controller features the highest quality enclosure, premium Schneider switchgear, intuitive capacitive touch keypad and Matelec Australia’s Market Leading HydroSTART Pro Control module.\u003c\/p\u003e\n\u003cp\u003eThe unit comes complete with pump current sensing and a wide range of electronic overload protection for both single and three phase pumps. A full suite of control inputs and functionality has been incorporated into the design to enhance the controller’s flexibility and cover an even wider range of pumping applications.\u003c\/p\u003e\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003ch4\u003eEnclosure Options\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eX15 orange powder coated galvanised mild steel, IP66 with inner door\u003c\/li\u003e\n\u003cli\u003eEnclosure size: 400x400x200mm\u003c\/li\u003e\n\u003cli\u003eEnclosure size will increase for optional additions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProtection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eInner door mounted main isolator with door interlock\u003c\/li\u003e\n\u003cli\u003ePremium Schneider Circuit Breakers for individual pump protection\/isolation\u003c\/li\u003e\n\u003cli\u003eLow voltage control and input circuitry\u003c\/li\u003e\n\u003cli\u003ePremium Schneider Contactors for pump switching (three phase panels)\u003c\/li\u003e\n\u003cli\u003eElectronic short and overload protection of alarms\u003c\/li\u003e\n\u003cli\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHydroSTART dual pump capacitive touch keypad interface\u003c\/li\u003e\n\u003cli\u003eIndicator lights for system, pump and input status, level alarm\u003c\/li\u003e\n\u003cli\u003eButtons for alarm mute\/reset and pump mode selection\u003c\/li\u003e\n\u003cli\u003eHydroSTART PCB control module with dip-switches for adjusting configuration\u003c\/li\u003e\n\u003cli\u003eVisual (strobe) and audible (buzzer) alarms\u003c\/li\u003e\n\u003cli\u003ePump current sensing providing adjustable overload \u0026amp; other protections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003ethree phase (400Vac) power supply\u003c\/li\u003e\n\u003cli\u003e6x digital inputs for float or pressure switches, optional prime loss flow switch and system enable\u003c\/li\u003e\n\u003cli\u003eStandard terminal setup: Low level, duty stop, duty start, standby start, high level and system enable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOutputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e2x pump supply outputs\u003c\/li\u003e\n\u003cli\u003eBMS volt free output for common fault\u003c\/li\u003e\n\u003cli\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFunctions\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eLevel control mode – Level empty operation controlled by up to 5 float switches\u003c\/li\u003e\n\u003cli\u003ePressure control mode – Pressure boost operation controlled by up to 3 pressure switches\u003c\/li\u003e\n\u003cli\u003eDuty sharing and alternation – Alternates on pump start and after set run times\u003c\/li\u003e\n\u003cli\u003eStaggered pump start – Prevents excessive current draw and reduces water surge\u003c\/li\u003e\n\u003cli\u003eManual pump control – Manual mode with optional timeout\u003c\/li\u003e\n\u003cli\u003eSystem enable input – Enables\/disables system in auto mode\u003c\/li\u003e\n\u003cli\u003eStatic duty mode – No duty alternation\u003c\/li\u003e\n\u003cli\u003eSmart chirp mode alarms – Audible alarm silences after 5 minutes, chirps every 5 minutes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFault Protection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHigh level alarm – Delayed alarm with auto\/manual reset depending on mode\u003c\/li\u003e\n\u003cli\u003eLow level protection – Shuts down pumps, manual reset only\u003c\/li\u003e\n\u003cli\u003eLow pressure protection – Shuts down pumps if input closed for 60 seconds\u003c\/li\u003e\n\u003cli\u003ePrime loss protection – Shuts down pumps if no flow for 30 seconds\u003c\/li\u003e\n\u003cli\u003ePump anti-seize protection – Runs pumps periodically during low use\u003c\/li\u003e\n\u003cli\u003ePump current sensing – Adjustable overload, undercurrent and zero current protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/49bb51d56250b36b65102dad6bfc116f753bea7e.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomation and Control Product Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/0fde2ce949a2d88c6cf6a1fee529c31b7451011f.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"Default Title","offer_id":45617355227245,"sku":"FPP-82243-X15","price":4413.2,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPP-82243-X15-product.webp?v=1786605791"},{"product_id":"hydrostart-submersible-level-controller-1ph-1-pump-0-1-16a-fpc-81141","title":"HydroSTART Submersible Level Controller (1PH 1 Pump 0.1-16A) - FPC-81141","description":"\u003cp\u003eThe HydroSTART Submersible Level Controller is designed for single pump applications, providing reliable level control, pump protection, and duty control. Featuring a capacitive touch interface, pump current sensing, and a range of electronic protection functions, the HydroSTART is suitable for a wide range of submersible pumping applications.\u003c\/p\u003e\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003ch4\u003eEnclosure\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003ePowder coated mild steel enclosure with removable gland plate\u003c\/li\u003e\n\u003cli\u003eIP54 rated with single door for indoor mounting\u003c\/li\u003e\n\u003cli\u003eEnclosure Size: 400×300×150 mm\u003c\/li\u003e\n\u003cli\u003eEnclosure size will increase for optional additions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProtection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSelectable overload range: 0.1-6 Amp, 5-16 Amp\u003c\/li\u003e\n\u003cli\u003ePad-lockable mains power isolator switch\u003c\/li\u003e\n\u003cli\u003eLow voltage control and input circuitry\u003c\/li\u003e\n\u003cli\u003eIndividual pump circuit breaker protection\/isolation\u003c\/li\u003e\n\u003cli\u003eElectronic short and overload protection\u003c\/li\u003e\n\u003cli\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHydroSTART single pump capacitive touch keypad interface\u003c\/li\u003e\n\u003cli\u003eIndicator lights for system and pump status\u003c\/li\u003e\n\u003cli\u003eButtons for alarm mute\/reset and pump mode selection\u003c\/li\u003e\n\u003cli\u003eHydroSTART PCB control module with dipswitches for adjusting configuration\u003c\/li\u003e\n\u003cli\u003eVisual (strobe) and audible (buzzer) alarms\u003c\/li\u003e\n\u003cli\u003ePump current sensing providing adjustable overload and other protections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSingle phase (230Vac) power supply\u003c\/li\u003e\n\u003cli\u003eUp to 6x digital inputs for float or pressure switches, optional prime loss flow switch and system enable\u003c\/li\u003e\n\u003cli\u003eStandard terminal setup: Low level, duty stop, duty start, standby start, high level and system enable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOutputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e1x pump supply output\u003c\/li\u003e\n\u003cli\u003eBMS volt-free output for common fault\u003c\/li\u003e\n\u003cli\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFunctions\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eLevel control mode for submersible pump applications\u003c\/li\u003e\n\u003cli\u003ePressure control mode for pressure boosting applications\u003c\/li\u003e\n\u003cli\u003eManual pump control\u003c\/li\u003e\n\u003cli\u003eSystem enable input\u003c\/li\u003e\n\u003cli\u003eStatic duty mode\u003c\/li\u003e\n\u003cli\u003eStaggered pump start\u003c\/li\u003e\n\u003cli\u003eSmart chirp mode alarms\u003c\/li\u003e\n\u003cli\u003ePump anti-seize protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFault Protection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHigh level alarm\u003c\/li\u003e\n\u003cli\u003eLow level protection\u003c\/li\u003e\n\u003cli\u003eLow pressure protection\u003c\/li\u003e\n\u003cli\u003ePrime loss protection\u003c\/li\u003e\n\u003cli\u003ePump current sensing with adjustable overload, undercurrent and zero current protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCommon Applications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSewage pump out\u003c\/li\u003e\n\u003cli\u003eStormwater pump out\u003c\/li\u003e\n\u003cli\u003eWater transfer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eDocumentation \u0026amp; Downloads\u003c\/h4\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/08f5a11902b64509503920491cac62bb60c5a92e.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"0.1-6 Amp","offer_id":45716078887021,"sku":"FPC-81141\/0.1-6Amp","price":1594.56,"currency_code":"AUD","in_stock":true},{"title":"5-16 Amp","offer_id":45716078919789,"sku":"FPC-81141\/5-16Amp","price":1594.56,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/d0287a6b03a6c9a339d52cb12b7be4094117744f-1250x1250.webp?v=1786685602"},{"product_id":"hydrostart-submersible-level-controller-1ph-1-pump-12-18a-fpc-81141-e","title":"HydroSTART Submersible Level Controller (1PH 1 Pump 12-18A) - FPC-81141-E","description":"\u003cp bis_size='{\"x\":12,\"y\":9,\"w\":689,\"h\":78,\"abs_x\":364,\"abs_y\":268}'\u003eThe HydroSTART Submersible Level Controller is designed for single pump applications, providing reliable level control, pump protection, and flexible control functionality. Featuring a capacitive touch interface, pump current sensing, and electronic protection, the HydroSTART is suitable for a wide range of submersible pumping applications.\u003c\/p\u003e\n\u003ch3 bis_size='{\"x\":12,\"y\":103,\"w\":689,\"h\":22,\"abs_x\":364,\"abs_y\":362}'\u003eProduct Details\u003c\/h3\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":137,\"w\":689,\"h\":19,\"abs_x\":364,\"abs_y\":396}'\u003eEnclosure\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":171,\"w\":689,\"h\":78,\"abs_x\":364,\"abs_y\":430}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":171,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":430}'\u003ePowder coated mild steel enclosure with removable gland plate\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":190,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":449}'\u003eIP54 rated with single door for indoor mounting\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":210,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":469}'\u003eEnclosure size: 400×300×150 mm\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":229,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":488}'\u003eEnclosure size will increase for optional additions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":263,\"w\":689,\"h\":19,\"abs_x\":364,\"abs_y\":522}'\u003eProtection\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":297,\"w\":689,\"h\":117,\"abs_x\":364,\"abs_y\":556}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":297,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":556}'\u003e12-18 Amp thermal overload rating\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":316,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":575}'\u003ePad-lockable mains power isolator switch\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":336,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":595}'\u003eLow voltage control and input circuitry\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":355,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":614}'\u003eIndividual pump circuit breaker protection\/isolation\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":375,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":634}'\u003eElectronic short and overload protection\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":394,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":653}'\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":428,\"w\":689,\"h\":19,\"abs_x\":364,\"abs_y\":687}'\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":462,\"w\":689,\"h\":117,\"abs_x\":364,\"abs_y\":721}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":462,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":721}'\u003eHydroSTART single pump capacitive touch keypad interface\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":481,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":740}'\u003eIndicator lights for system and pump status\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":501,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":760}'\u003eButtons for alarm mute\/reset and pump mode selection\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":520,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":779}'\u003eHydroSTART PCB control module with dipswitches for adjusting configuration\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":540,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":799}'\u003eVisual (strobe) and audible (buzzer) alarms\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":560,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":819}'\u003ePump current sensing providing adjustable overload and other protections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":593,\"w\":689,\"h\":19,\"abs_x\":364,\"abs_y\":852}'\u003eInputs\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":627,\"w\":689,\"h\":58,\"abs_x\":364,\"abs_y\":886}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":627,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":886}'\u003eSingle phase (230Vac) power supply\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":646,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":905}'\u003eUp to 6x digital inputs for float or pressure switches, optional prime loss flow switch and system enable\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":666,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":925}'\u003eStandard terminal setup: Low level, duty stop, duty start, standby start, high level and system enable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":700,\"w\":689,\"h\":19,\"abs_x\":364,\"abs_y\":959}'\u003eOutputs\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":733,\"w\":689,\"h\":58,\"abs_x\":364,\"abs_y\":992}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":733,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":992}'\u003e1x pump supply output\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":753,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":1012}'\u003eBMS volt-free output for common fault\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":772,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":1031}'\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":806,\"w\":689,\"h\":19,\"abs_x\":364,\"abs_y\":1065}'\u003eFunctions\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":840,\"w\":689,\"h\":156,\"abs_x\":364,\"abs_y\":1099}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":840,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":1099}'\u003eLevel control mode for submersible pump applications\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":859,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":1118}'\u003ePressure control mode for pressure boosting applications\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":879,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":1138}'\u003eManual pump control\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":898,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":1157}'\u003eSystem enable input\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":918,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":1177}'\u003eStatic duty mode\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":938,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":1197}'\u003eStaggered pump start\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":957,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":1216}'\u003eSmart chirp mode alarms\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":977,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":1236}'\u003ePump anti-seize protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":1010,\"w\":689,\"h\":19,\"abs_x\":364,\"abs_y\":1269}'\u003eFault Protection\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":1044,\"w\":689,\"h\":97,\"abs_x\":364,\"abs_y\":1303}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1044,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":1303}'\u003eHigh level alarm\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1064,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":1323}'\u003eLow level protection\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1083,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":1342}'\u003eLow pressure protection\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1103,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":1362}'\u003ePrime loss protection\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1122,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":1381}'\u003ePump current sensing with adjustable overload, undercurrent and zero current protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 bis_size='{\"x\":12,\"y\":1156,\"w\":689,\"h\":22,\"abs_x\":364,\"abs_y\":1415}'\u003eCommon Applications\u003c\/h3\u003e\n\u003cul bis_size='{\"x\":12,\"y\":1193,\"w\":689,\"h\":97,\"abs_x\":364,\"abs_y\":1452}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1193,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":1452}'\u003eSewage pump out\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1212,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":1471}'\u003eStormwater pump out\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1232,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":1491}'\u003eWater transfer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 bis_size='{\"x\":12,\"y\":1305,\"w\":689,\"h\":22,\"abs_x\":364,\"abs_y\":1564}'\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\" bis_size='{\"x\":12,\"y\":1338,\"w\":689,\"h\":29,\"abs_x\":364,\"abs_y\":1597}'\u003e\n\u003ctbody bis_size='{\"x\":15,\"y\":1341,\"w\":683,\"h\":23,\"abs_x\":367,\"abs_y\":1600}'\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":1341,\"w\":683,\"h\":23,\"abs_x\":367,\"abs_y\":1600}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":1341,\"w\":442,\"h\":23,\"abs_x\":367,\"abs_y\":1600}'\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":459,\"y\":1341,\"w\":238,\"h\":23,\"abs_x\":811,\"abs_y\":1600}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/08f5a11902b64509503920491cac62bb60c5a92e.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":461,\"y\":1343,\"w\":63,\"h\":19,\"abs_x\":813,\"abs_y\":1602}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"Default Title","offer_id":45617399431277,"sku":"FPC-81141-E","price":1700.16,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/d0287a6b03a6c9a339d52cb12b7be4094117744f-1250x1250.webp?v=1786685602"},{"product_id":"hydrostart-submersible-level-controller-3ph-1-pump-0-1-16a-fpc-81143","title":"HydroSTART Submersible Level Controller (3PH 1 Pump 0.1-16A) - FPC-81143","description":"\u003cp bis_size='{\"x\":12,\"y\":9,\"w\":689,\"h\":78,\"abs_x\":364,\"abs_y\":268}'\u003eThe HydroSTART Submersible Level Controller is designed for single pump applications, providing reliable level control, pump protection, and flexible control functionality. Featuring a capacitive touch interface, pump current sensing, and electronic protection, the HydroSTART is suitable for a wide range of submersible pumping applications.\u003c\/p\u003e\n\u003ch3 bis_size='{\"x\":12,\"y\":103,\"w\":689,\"h\":22,\"abs_x\":364,\"abs_y\":362}'\u003eProduct Details\u003c\/h3\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":137,\"w\":689,\"h\":19,\"abs_x\":364,\"abs_y\":396}'\u003eEnclosure\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":171,\"w\":689,\"h\":78,\"abs_x\":364,\"abs_y\":430}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":171,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":430}'\u003ePowder coated mild steel enclosure with removable gland plate\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":190,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":449}'\u003eIP54 rated with single door for indoor mounting\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":210,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":469}'\u003eEnclosure size: 400×300×150 mm\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":229,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":488}'\u003eEnclosure size will increase for optional additions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":263,\"w\":689,\"h\":19,\"abs_x\":364,\"abs_y\":522}'\u003eProtection\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":297,\"w\":689,\"h\":137,\"abs_x\":364,\"abs_y\":556}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":297,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":556}'\u003eSelectable overload range: 0.1-6 Amp, 5-16 Amp\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":316,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":575}'\u003ePad-lockable mains power isolator switch\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":336,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":595}'\u003eLow voltage control and input circuitry\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":355,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":614}'\u003eIndividual pump circuit breaker protection\/isolation\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":375,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":634}'\u003eContactors for pump switching\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":394,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":653}'\u003eElectronic short and overload protection\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":414,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":673}'\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":448,\"w\":689,\"h\":19,\"abs_x\":364,\"abs_y\":707}'\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":481,\"w\":689,\"h\":117,\"abs_x\":364,\"abs_y\":740}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":481,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":740}'\u003eHydroSTART single pump capacitive touch keypad interface\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":501,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":760}'\u003eIndicator lights for system and pump status\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":520,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":779}'\u003eButtons for alarm mute\/reset and pump mode selection\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":540,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":799}'\u003eHydroSTART PCB control module with dipswitches for adjusting configuration\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":560,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":819}'\u003eVisual (strobe) and audible (buzzer) alarms\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":579,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":838}'\u003ePump current sensing providing adjustable overload and other protections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":613,\"w\":689,\"h\":19,\"abs_x\":364,\"abs_y\":872}'\u003eInputs\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":646,\"w\":689,\"h\":58,\"abs_x\":364,\"abs_y\":905}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":646,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":905}'\u003eThree phase (400Vac) power supply\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":666,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":925}'\u003eUp to 6x digital inputs for float or pressure switches, optional prime loss flow switch and system enable\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":686,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":945}'\u003eStandard terminal setup: Low level, duty stop, duty start, standby start, high level and system enable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":719,\"w\":689,\"h\":19,\"abs_x\":364,\"abs_y\":978}'\u003eOutputs\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":753,\"w\":689,\"h\":58,\"abs_x\":364,\"abs_y\":1012}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":753,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":1012}'\u003e1x pump supply output\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":772,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":1031}'\u003eBMS volt-free output for common fault\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":792,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":1051}'\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":826,\"w\":689,\"h\":19,\"abs_x\":364,\"abs_y\":1085}'\u003eFunctions\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":859,\"w\":689,\"h\":156,\"abs_x\":364,\"abs_y\":1118}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":859,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":1118}'\u003eLevel control mode for submersible pump applications\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":879,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":1138}'\u003ePressure control mode for pressure boosting applications\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":898,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":1157}'\u003eManual pump control\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":918,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":1177}'\u003eSystem enable input\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":938,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":1197}'\u003eStatic duty mode\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":957,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":1216}'\u003eStaggered pump start\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":977,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":1236}'\u003eSmart chirp mode alarms\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":996,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":1255}'\u003ePump anti-seize protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":1030,\"w\":689,\"h\":19,\"abs_x\":364,\"abs_y\":1289}'\u003eFault Protection\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":1064,\"w\":689,\"h\":97,\"abs_x\":364,\"abs_y\":1323}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1064,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":1323}'\u003eHigh level alarm\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1083,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":1342}'\u003eLow level protection\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1103,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":1362}'\u003eLow pressure protection\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1122,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":1381}'\u003ePrime loss protection\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1142,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":1401}'\u003ePump current sensing with adjustable overload, undercurrent and zero current protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 bis_size='{\"x\":12,\"y\":1175,\"w\":689,\"h\":22,\"abs_x\":364,\"abs_y\":1434}'\u003eCommon Applications\u003c\/h3\u003e\n\u003cul bis_size='{\"x\":12,\"y\":1212,\"w\":689,\"h\":97,\"abs_x\":364,\"abs_y\":1471}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1212,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":1471}'\u003eSewage pump out\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1232,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":1491}'\u003eStormwater pump out\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1252,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":1511}'\u003eWater transfer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 bis_size='{\"x\":12,\"y\":1324,\"w\":689,\"h\":22,\"abs_x\":364,\"abs_y\":1583}'\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\" bis_size='{\"x\":12,\"y\":1358,\"w\":689,\"h\":29,\"abs_x\":364,\"abs_y\":1617}'\u003e\n\u003ctbody bis_size='{\"x\":15,\"y\":1361,\"w\":683,\"h\":23,\"abs_x\":367,\"abs_y\":1620}'\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":1361,\"w\":683,\"h\":23,\"abs_x\":367,\"abs_y\":1620}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":1361,\"w\":442,\"h\":23,\"abs_x\":367,\"abs_y\":1620}'\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":459,\"y\":1361,\"w\":238,\"h\":23,\"abs_x\":811,\"abs_y\":1620}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/08f5a11902b64509503920491cac62bb60c5a92e.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":461,\"y\":1363,\"w\":63,\"h\":19,\"abs_x\":813,\"abs_y\":1622}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"0.1-6 Amp","offer_id":45716079706221,"sku":"FPC-81143\/0.1-6Amp","price":1650.88,"currency_code":"AUD","in_stock":true},{"title":"5-16 Amp","offer_id":45716079738989,"sku":"FPC-81143\/5-16Amp","price":1650.88,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/d0287a6b03a6c9a339d52cb12b7be4094117744f-1250x1250.webp?v=1786685602"},{"product_id":"hydrostart-submersible-level-controller-3ph-1-pump-12-18a-fpc-81143-e","title":"HydroSTART Submersible Level Controller (3PH 1 Pump 12-18A) - FPC-81143-E","description":"\u003cp bis_size='{\"x\":12,\"y\":9,\"w\":689,\"h\":78,\"abs_x\":364,\"abs_y\":268}'\u003eThe HydroSTART Submersible Level Controller is designed for single pump applications, providing reliable level control, pump protection, and flexible control functionality. Featuring a capacitive touch interface, pump current sensing, and electronic protection, the HydroSTART is suitable for a wide range of submersible pumping applications.\u003c\/p\u003e\n\u003ch3 bis_size='{\"x\":12,\"y\":103,\"w\":689,\"h\":22,\"abs_x\":364,\"abs_y\":362}'\u003eProduct Details\u003c\/h3\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":137,\"w\":689,\"h\":19,\"abs_x\":364,\"abs_y\":396}'\u003eEnclosure\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":171,\"w\":689,\"h\":78,\"abs_x\":364,\"abs_y\":430}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":171,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":430}'\u003ePowder coated mild steel enclosure with removable gland plate\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":190,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":449}'\u003eIP54 rated with single door for indoor mounting\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":210,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":469}'\u003eEnclosure size: 400×300×150 mm\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":229,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":488}'\u003eEnclosure size will increase for optional additions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":263,\"w\":689,\"h\":19,\"abs_x\":364,\"abs_y\":522}'\u003eProtection\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":297,\"w\":689,\"h\":137,\"abs_x\":364,\"abs_y\":556}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":297,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":556}'\u003e12-18 Amp thermal overload rating\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":316,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":575}'\u003ePad-lockable mains power isolator switch\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":336,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":595}'\u003eLow voltage control and input circuitry\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":355,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":614}'\u003eIndividual pump circuit breaker protection\/isolation\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":375,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":634}'\u003eContactors for pump switching\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":394,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":653}'\u003eElectronic short and overload protection\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":414,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":673}'\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":448,\"w\":689,\"h\":19,\"abs_x\":364,\"abs_y\":707}'\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":481,\"w\":689,\"h\":117,\"abs_x\":364,\"abs_y\":740}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":481,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":740}'\u003eHydroSTART single pump capacitive touch keypad interface\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":501,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":760}'\u003eIndicator lights for system and pump status\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":520,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":779}'\u003eButtons for alarm mute\/reset and pump mode selection\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":540,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":799}'\u003eHydroSTART PCB control module with dipswitches for adjusting configuration\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":560,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":819}'\u003eVisual (strobe) and audible (buzzer) alarms\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":579,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":838}'\u003ePump current sensing providing adjustable overload and other protections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":613,\"w\":689,\"h\":19,\"abs_x\":364,\"abs_y\":872}'\u003eInputs\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":646,\"w\":689,\"h\":58,\"abs_x\":364,\"abs_y\":905}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":646,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":905}'\u003eThree phase (400Vac) power supply\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":666,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":925}'\u003eUp to 6x digital inputs for float or pressure switches, optional prime loss flow switch and system enable\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":686,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":945}'\u003eStandard terminal setup: Low level, duty stop, duty start, standby start, high level and system enable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":719,\"w\":689,\"h\":19,\"abs_x\":364,\"abs_y\":978}'\u003eOutputs\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":753,\"w\":689,\"h\":58,\"abs_x\":364,\"abs_y\":1012}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":753,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":1012}'\u003e1x pump supply output\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":772,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":1031}'\u003eBMS volt-free output for common fault\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":792,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":1051}'\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":826,\"w\":689,\"h\":19,\"abs_x\":364,\"abs_y\":1085}'\u003eFunctions\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":859,\"w\":689,\"h\":156,\"abs_x\":364,\"abs_y\":1118}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":859,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":1118}'\u003eLevel control mode for submersible pump applications\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":879,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":1138}'\u003ePressure control mode for pressure boosting applications\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":898,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":1157}'\u003eManual pump control\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":918,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":1177}'\u003eSystem enable input\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":938,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":1197}'\u003eStatic duty mode\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":957,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":1216}'\u003eStaggered pump start\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":977,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":1236}'\u003eSmart chirp mode alarms\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":996,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":1255}'\u003ePump anti-seize protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":1030,\"w\":689,\"h\":19,\"abs_x\":364,\"abs_y\":1289}'\u003eFault Protection\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":1064,\"w\":689,\"h\":97,\"abs_x\":364,\"abs_y\":1323}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1064,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":1323}'\u003eHigh level alarm\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1083,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":1342}'\u003eLow level protection\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1103,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":1362}'\u003eLow pressure protection\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1122,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":1381}'\u003ePrime loss protection\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1142,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":1401}'\u003ePump current sensing with adjustable overload, undercurrent and zero current protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 bis_size='{\"x\":12,\"y\":1175,\"w\":689,\"h\":22,\"abs_x\":364,\"abs_y\":1434}'\u003eCommon Applications\u003c\/h3\u003e\n\u003cul bis_size='{\"x\":12,\"y\":1212,\"w\":689,\"h\":97,\"abs_x\":364,\"abs_y\":1471}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1212,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":1471}'\u003eSewage pump out\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1232,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":1491}'\u003eStormwater pump out\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1252,\"w\":649,\"h\":19,\"abs_x\":404,\"abs_y\":1511}'\u003eWater transfer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 bis_size='{\"x\":12,\"y\":1324,\"w\":689,\"h\":22,\"abs_x\":364,\"abs_y\":1583}'\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\" bis_size='{\"x\":12,\"y\":1358,\"w\":689,\"h\":29,\"abs_x\":364,\"abs_y\":1617}'\u003e\n\u003ctbody bis_size='{\"x\":15,\"y\":1361,\"w\":683,\"h\":23,\"abs_x\":367,\"abs_y\":1620}'\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":1361,\"w\":683,\"h\":23,\"abs_x\":367,\"abs_y\":1620}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":1361,\"w\":442,\"h\":23,\"abs_x\":367,\"abs_y\":1620}'\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":459,\"y\":1361,\"w\":238,\"h\":23,\"abs_x\":811,\"abs_y\":1620}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/08f5a11902b64509503920491cac62bb60c5a92e.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":461,\"y\":1363,\"w\":63,\"h\":19,\"abs_x\":813,\"abs_y\":1622}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"Default Title","offer_id":45617400217709,"sku":"FPC-81143-E","price":1747.68,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/d0287a6b03a6c9a339d52cb12b7be4094117744f-1250x1250.webp?v=1786685602"}],"url":"https:\/\/pumptastic.com.au\/collections\/pump-controllers.oembed?page=2","provider":"Pumptastic","version":"1.0","type":"link"}