{"title":"Advanced Pump Controllers","description":"\u003cp\u003eAdvanced pump controllers designed to provide enhanced control, monitoring and management of water pumping systems.\u003c\/p\u003e","products":[{"product_id":"hydrowhiz-submersible-level-controller-1ph-1-pump-fpc-63141-aa-d","title":"HydroWHIZ Submersible Level Controller (1PH 1 Pump) - FPC-63141-(AA-D)","description":"\u003cp\u003eMATelec Australia's HydroWHIZ Controller has been designed with ease of use at the core of the system design. Building on the wealth of the pump control features in the Advanced controller, the HydroWHIZ brings these features into a new age with a colour touch screen interface and a streamlined setup process. In a world where information is power the HydroWHIZ has extensive time and date stamped alarms, logged data, trend graphs and diagnostic pages to provide the user with all the information required for optimisation and preventative maintenance. Featuring the flexibility of level, pressure and temperature system modes with a wide range of functions and protections, the HydroWHIZ controller is ideal for a vast range of applications including water transfer, stormwater and sewage pump out, pressure boosting, hot water circulation and chiller supply, to name a few.\u003c\/p\u003e\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003ch4\u003eEnclosure\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIP56 rated, powder coated mild steel enclosure with inner door and removable gland plate\u003c\/li\u003e\n\u003cli\u003eEnclosure size: 400x400x250mm+\u003c\/li\u003e\n\u003cli\u003eEnclosure size will increase for high overload ratings and optional additions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProtection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003ePad-lockable mains power isolator switch\u003c\/li\u003e\n\u003cli\u003eCircuit breaker protected low voltage control and input circuitry\u003c\/li\u003e\n\u003cli\u003eIndividual pump isolation\u003c\/li\u003e\n\u003cli\u003eContactor and thermal overload protection of pump motors\u003c\/li\u003e\n\u003cli\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHydroWHIZ colour touch screen HMI (see interface features)\u003c\/li\u003e\n\u003cli\u003eHydroWHIZ PCB control module\u003c\/li\u003e\n\u003cli\u003eVisual (strobe) and mutable audible (buzzer) alarms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSingle phase (230Vac) power supply\u003c\/li\u003e\n\u003cli\u003eAnalog 4-20mA input for level, pressure or temperature transducer\u003c\/li\u003e\n\u003cli\u003eUp to 8x digital 24Vdc inputs for low, stop, start, standby start and high float switches, pressure switches or thermostats, system enable\/disable input and a low flow switch\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOutputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e1 pump output\u003c\/li\u003e\n\u003cli\u003eBMS volt-free output for common fault\u003c\/li\u003e\n\u003cli\u003eAnalog 0-10V output (mirrors analog input)\u003c\/li\u003e\n\u003cli\u003eOutput for solenoid valve available on request\u003c\/li\u003e\n\u003cli\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommon Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWater transfer\u003c\/li\u003e\n\u003cli\u003eTank fill\u003c\/li\u003e\n\u003cli\u003eSewage pump out\u003c\/li\u003e\n\u003cli\u003eStormwater pump out\u003c\/li\u003e\n\u003cli\u003ePressure boosting\u003c\/li\u003e\n\u003cli\u003eHot water recirculation\u003c\/li\u003e\n\u003cli\u003eChiller supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/e54d9eba0e4ab3257a8d93c1c52aaa5a00c4f088.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/0fde2ce949a2d88c6cf6a1fee529c31b7451011f.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation Manual\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/fdc519f87300ef0ff4be440566ef9e32807e6c39.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuick Start Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/c13fbd566a0336d45cfecb1d3ad611f50101893b.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"-AA (1.6-2.5 Amp)","offer_id":45591606263917,"sku":"FPC-63141-AA","price":2823.92,"currency_code":"AUD","in_stock":true},{"title":"-A (2.5-4 Amp)","offer_id":45591606657133,"sku":"FPC-63141-A","price":2823.92,"currency_code":"AUD","in_stock":true},{"title":"-B (4-6 Amp)","offer_id":45591607050349,"sku":"FPC-63141-B","price":2823.92,"currency_code":"AUD","in_stock":true},{"title":"-BB (5.5-8 Amp)","offer_id":45591607443565,"sku":"FPC-63141-BB","price":2823.92,"currency_code":"AUD","in_stock":true},{"title":"-C (7-10 Amp)","offer_id":45591607836781,"sku":"FPC-63141-C","price":2823.92,"currency_code":"AUD","in_stock":true},{"title":"-D (9-13 Amp)","offer_id":45591608229997,"sku":"FPC-63141-D","price":2823.92,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPC-63141-product.webp?v=1785388512"},{"product_id":"hydrowhiz-submersible-level-controller-3ph-1-pump-fpc-63143-aa-d","title":"HydroWHIZ Submersible Level Controller (3PH 1 Pump) - FPC-63143-(AA-D)","description":"\u003cp bis_size='{\"x\":12,\"y\":9,\"w\":560,\"h\":195,\"abs_x\":618,\"abs_y\":270}'\u003eMATelec Australia's HydroWHIZ Controller has been designed with ease of use at the core of the system design. Building on the wealth of the pump control features in the Advanced controller, the HydroWHIZ brings these features into a new age with a colour touch screen interface and a streamlined setup process. In a world where information is power the HydroWHIZ has extensive time and date stamped alarms, logged data, trend graphs and diagnostic pages to provide the user with all the information required for optimisation and preventative maintenance. Featuring the flexibility of level, pressure and temperature system modes with a wide range of functions and protections, the HydroWHIZ controller is ideal for a vast range of applications including water transfer, stormwater and sewage pump out, pressure boosting, hot water circulation and chiller supply, to name a few.\u003c\/p\u003e\n\u003ch3 bis_size='{\"x\":12,\"y\":221,\"w\":560,\"h\":22,\"abs_x\":618,\"abs_y\":482}'\u003eProduct Details\u003c\/h3\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":255,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":516}'\u003eEnclosure\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":288,\"w\":560,\"h\":58,\"abs_x\":618,\"abs_y\":549}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":288,\"w\":520,\"h\":39,\"abs_x\":658,\"abs_y\":549}'\u003eIP56 rated, powder coated mild steel enclosure with inner door and removable gland plate\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":327,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":588}'\u003eEnclosure size: 400x400x250mm+\u003c\/li\u003e\n\u003cli\u003eEnclosure size will increase for high overload ratings and optional additions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":361,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":622}'\u003eProtection\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":394,\"w\":560,\"h\":97,\"abs_x\":618,\"abs_y\":655}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":394,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":655}'\u003ePad-lockable mains power isolator switch\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":414,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":675}'\u003eCircuit breaker protected low voltage control and input circuitry\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":434,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":695}'\u003eIndividual pump isolation\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":453,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":714}'\u003eContactor and thermal overload protection of pump motors\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":473,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":734}'\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":506,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":767}'\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":540,\"w\":560,\"h\":58,\"abs_x\":618,\"abs_y\":801}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":540,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":801}'\u003eHydroWHIZ colour touch screen HMI (see interface features)\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":560,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":821}'\u003eHydroWHIZ PCB control module\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":579,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":840}'\u003eVisual (strobe) and mutable audible (buzzer) alarms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":613,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":874}'\u003eInputs\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":646,\"w\":560,\"h\":117,\"abs_x\":618,\"abs_y\":907}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":646,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":907}'\u003eThree phase (400Vac) power supply\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":666,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":927}'\u003eAnalog 4-20mA input for level, pressure or temperature transducer\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":686,\"w\":520,\"h\":58,\"abs_x\":658,\"abs_y\":947}'\u003eUp to 8x digital 24Vdc inputs for low, stop, start, standby start and high float switches, pressure switches or thermostats, system enable\/disable input and a low flow switch\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":744,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1005}'\u003eThermal switch inputs per pump (three phase only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":778,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":1039}'\u003eOutputs\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":812,\"w\":560,\"h\":97,\"abs_x\":618,\"abs_y\":1073}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":812,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1073}'\u003e1 pump output\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":831,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1092}'\u003eBMS volt-free output for common fault\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":851,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1112}'\u003eAnalog 0-10V output (mirrors analog input)\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":870,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1131}'\u003eOutput for solenoid valve available on request\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":890,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1151}'\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 bis_size='{\"x\":12,\"y\":924,\"w\":560,\"h\":22,\"abs_x\":618,\"abs_y\":1185}'\u003eCommon Applications\u003c\/h3\u003e\n\u003cul bis_size='{\"x\":12,\"y\":960,\"w\":560,\"h\":137,\"abs_x\":618,\"abs_y\":1221}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":960,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1221}'\u003eWater transfer\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":980,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1241}'\u003eTank fill\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1000,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1261}'\u003eSewage pump out\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1019,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1280}'\u003eStormwater pump out\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1039,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1300}'\u003ePressure boosting\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1058,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1319}'\u003eHot water recirculation\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1078,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1339}'\u003eChiller supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 bis_size='{\"x\":12,\"y\":1112,\"w\":560,\"h\":22,\"abs_x\":618,\"abs_y\":1373}'\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\" bis_size='{\"x\":12,\"y\":1145,\"w\":560,\"h\":106,\"abs_x\":618,\"abs_y\":1406}'\u003e\n\u003ctbody bis_size='{\"x\":15,\"y\":1148,\"w\":554,\"h\":100,\"abs_x\":621,\"abs_y\":1409}'\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":1148,\"w\":554,\"h\":23,\"abs_x\":621,\"abs_y\":1409}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":1148,\"w\":358,\"h\":23,\"abs_x\":621,\"abs_y\":1409}'\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":375,\"y\":1148,\"w\":193,\"h\":23,\"abs_x\":981,\"abs_y\":1409}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/e54d9eba0e4ab3257a8d93c1c52aaa5a00c4f088.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":377,\"y\":1150,\"w\":63,\"h\":19,\"abs_x\":983,\"abs_y\":1411}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":1174,\"w\":554,\"h\":23,\"abs_x\":621,\"abs_y\":1435}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":1174,\"w\":358,\"h\":23,\"abs_x\":621,\"abs_y\":1435}'\u003eProduct Guide\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":375,\"y\":1174,\"w\":193,\"h\":23,\"abs_x\":981,\"abs_y\":1435}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/0fde2ce949a2d88c6cf6a1fee529c31b7451011f.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":377,\"y\":1176,\"w\":63,\"h\":19,\"abs_x\":983,\"abs_y\":1437}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":1199,\"w\":554,\"h\":23,\"abs_x\":621,\"abs_y\":1460}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":1199,\"w\":358,\"h\":23,\"abs_x\":621,\"abs_y\":1460}'\u003eOperation Manual\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":375,\"y\":1199,\"w\":193,\"h\":23,\"abs_x\":981,\"abs_y\":1460}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/fdc519f87300ef0ff4be440566ef9e32807e6c39.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":377,\"y\":1201,\"w\":63,\"h\":19,\"abs_x\":983,\"abs_y\":1462}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":1225,\"w\":554,\"h\":23,\"abs_x\":621,\"abs_y\":1486}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":1225,\"w\":358,\"h\":23,\"abs_x\":621,\"abs_y\":1486}'\u003eQuick Start Guide\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":375,\"y\":1225,\"w\":193,\"h\":23,\"abs_x\":981,\"abs_y\":1486}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/c13fbd566a0336d45cfecb1d3ad611f50101893b.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":377,\"y\":1227,\"w\":63,\"h\":19,\"abs_x\":983,\"abs_y\":1488}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"-AA (1.6-2.5 Amp)","offer_id":45591612096621,"sku":"FPC-63143-AA","price":2884.64,"currency_code":"AUD","in_stock":true},{"title":"-A (2.5-4 Amp)","offer_id":45591612489837,"sku":"FPC-63143-A","price":2884.64,"currency_code":"AUD","in_stock":true},{"title":"-B (4-6 Amp)","offer_id":45591612883053,"sku":"FPC-63143-B","price":2884.64,"currency_code":"AUD","in_stock":true},{"title":"-BB (5.5-8 Amp)","offer_id":45591613276269,"sku":"FPC-63143-BB","price":2884.64,"currency_code":"AUD","in_stock":true},{"title":"-C (7-10 Amp)","offer_id":45591613669485,"sku":"FPC-63143-C","price":2884.64,"currency_code":"AUD","in_stock":true},{"title":"-D (9-13 Amp)","offer_id":45591614062701,"sku":"FPC-63143-D","price":2884.64,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPC-63143-product.webp?v=1785393097"},{"product_id":"hydrowhiz-submersible-level-controller-2ph-1-pump-fpc-63141-aa-d","title":"HydroWHIZ Submersible Level Controller (1PH 2 Pump) - FPC-63241-(AA-D)","description":"\u003cp\u003eMATelec Australia's HydroWHIZ Controller has been designed with ease of use at the core of the system design. Building on the wealth of the pump control features in the Advanced controller, the HydroWHIZ brings these features into a new age with a colour touch screen interface and a streamlined setup process. In a world where information is power the HydroWHIZ has extensive time and date stamped alarms, logged data, trend graphs and diagnostic pages to provide the user with all the information required for optimisation and preventative maintenance. Featuring the flexibility of level, pressure and temperature system modes with a wide range of functions and protections, the HydroWHIZ controller is ideal for a vast range of applications including water transfer, stormwater and sewage pump out, pressure boosting, hot water circulation and chiller supply, to name a few.\u003c\/p\u003e\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003ch4\u003eEnclosure\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIP56 rated, powder coated mild steel enclosure with inner door and removable gland plate\u003c\/li\u003e\n\u003cli\u003eEnclosure size: 400x400x250mm+\u003c\/li\u003e\n\u003cli\u003eEnclosure size will increase for high overload ratings and optional additions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProtection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003ePad-lockable mains power isolator switch\u003c\/li\u003e\n\u003cli\u003eCircuit breaker protected low voltage control and input circuitry\u003c\/li\u003e\n\u003cli\u003eIndividual pump isolation\u003c\/li\u003e\n\u003cli\u003eContactor and thermal overload protection of pump motors\u003c\/li\u003e\n\u003cli\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHydroWHIZ colour touch screen HMI (see interface features)\u003c\/li\u003e\n\u003cli\u003eHydroWHIZ PCB control module\u003c\/li\u003e\n\u003cli\u003eVisual (strobe) and mutable audible (buzzer) alarms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSingle phase (230Vac) power supply\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eAnalog 4-20mA input for level, pressure or temperature transducer\u003c\/li\u003e\n\u003cli\u003eUp to 8x digital 24Vdc inputs for low, stop, start, standby start and high float switches, pressure switches or thermostats, system enable\/disable input and a low flow switch\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOutputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e2 pump output\u003c\/li\u003e\n\u003cli\u003eBMS volt-free output for common fault\u003c\/li\u003e\n\u003cli\u003eAnalog 0-10V output (mirrors analog input)\u003c\/li\u003e\n\u003cli\u003eOutput for solenoid valve available on request\u003c\/li\u003e\n\u003cli\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommon Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWater transfer\u003c\/li\u003e\n\u003cli\u003eTank fill\u003c\/li\u003e\n\u003cli\u003eSewage pump out\u003c\/li\u003e\n\u003cli\u003eStormwater pump out\u003c\/li\u003e\n\u003cli\u003ePressure boosting\u003c\/li\u003e\n\u003cli\u003eHot water recirculation\u003c\/li\u003e\n\u003cli\u003eChiller supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/e54d9eba0e4ab3257a8d93c1c52aaa5a00c4f088.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/0fde2ce949a2d88c6cf6a1fee529c31b7451011f.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation Manual\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/fdc519f87300ef0ff4be440566ef9e32807e6c39.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuick Start Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/c13fbd566a0336d45cfecb1d3ad611f50101893b.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"-AA (1.6-2.5 Amp)","offer_id":45591610622061,"sku":"FPC-63241-AA","price":3037.76,"currency_code":"AUD","in_stock":true},{"title":"-A (2.5-4 Amp)","offer_id":45591610654829,"sku":"FPC-63241-A","price":3037.76,"currency_code":"AUD","in_stock":true},{"title":"-B (4-6 Amp)","offer_id":45591610687597,"sku":"FPC-63241-B","price":3037.76,"currency_code":"AUD","in_stock":true},{"title":"-BB (5.5-8 Amp)","offer_id":45591610720365,"sku":"FPC-63241-BB","price":3037.76,"currency_code":"AUD","in_stock":true},{"title":"-C (7-10 Amp)","offer_id":45591610753133,"sku":"FPC-63241-C","price":3037.76,"currency_code":"AUD","in_stock":true},{"title":"-D (9-13 Amp)","offer_id":45591610785901,"sku":"FPC-63241-D","price":3037.76,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPC-63241-product.webp?v=1785394900"},{"product_id":"hydrowhiz-submersible-level-controller-3ph-2-pump-fpc-63243-aa-d","title":"HydroWHIZ Submersible Level Controller (3PH 2 Pump) - FPC-63243-(AA-D)","description":"\u003cp bis_size='{\"x\":12,\"y\":9,\"w\":560,\"h\":195,\"abs_x\":618,\"abs_y\":270}'\u003eMATelec Australia's HydroWHIZ Controller has been designed with ease of use at the core of the system design. Building on the wealth of the pump control features in the Advanced controller, the HydroWHIZ brings these features into a new age with a colour touch screen interface and a streamlined setup process. In a world where information is power the HydroWHIZ has extensive time and date stamped alarms, logged data, trend graphs and diagnostic pages to provide the user with all the information required for optimisation and preventative maintenance. Featuring the flexibility of level, pressure and temperature system modes with a wide range of functions and protections, the HydroWHIZ controller is ideal for a vast range of applications including water transfer, stormwater and sewage pump out, pressure boosting, hot water circulation and chiller supply, to name a few.\u003c\/p\u003e\n\u003ch3 bis_size='{\"x\":12,\"y\":221,\"w\":560,\"h\":22,\"abs_x\":618,\"abs_y\":482}'\u003eProduct Details\u003c\/h3\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":255,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":516}'\u003eEnclosure\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":288,\"w\":560,\"h\":58,\"abs_x\":618,\"abs_y\":549}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":288,\"w\":520,\"h\":39,\"abs_x\":658,\"abs_y\":549}'\u003eIP56 rated, powder coated mild steel enclosure with inner door and removable gland plate\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":327,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":588}'\u003eEnclosure size: 400x400x250mm+\u003c\/li\u003e\n\u003cli\u003eEnclosure size will increase for high overload ratings and optional additions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":361,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":622}'\u003eProtection\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":394,\"w\":560,\"h\":97,\"abs_x\":618,\"abs_y\":655}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":394,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":655}'\u003ePad-lockable mains power isolator switch\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":414,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":675}'\u003eCircuit breaker protected low voltage control and input circuitry\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":434,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":695}'\u003eIndividual pump isolation\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":453,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":714}'\u003eContactor and thermal overload protection of pump motors\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":473,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":734}'\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":506,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":767}'\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":540,\"w\":560,\"h\":58,\"abs_x\":618,\"abs_y\":801}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":540,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":801}'\u003eHydroWHIZ colour touch screen HMI (see interface features)\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":560,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":821}'\u003eHydroWHIZ PCB control module\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":579,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":840}'\u003eVisual (strobe) and mutable audible (buzzer) alarms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":613,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":874}'\u003eInputs\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":646,\"w\":560,\"h\":117,\"abs_x\":618,\"abs_y\":907}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":646,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":907}'\u003eThree phase (400Vac) power supply\u003cbr bis_size='{\"x\":270,\"y\":646,\"w\":0,\"h\":19,\"abs_x\":876,\"abs_y\":907}'\u003e\n\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":666,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":927}'\u003eAnalog 4-20mA input for level, pressure or temperature transducer\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":686,\"w\":520,\"h\":58,\"abs_x\":658,\"abs_y\":947}'\u003eUp to 8x digital 24Vdc inputs for low, stop, start, standby start and high float switches, pressure switches or thermostats, system enable\/disable input and a low flow switch\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":744,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1005}'\u003eThermal switch inputs per pump (three phase only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":778,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":1039}'\u003eOutputs\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":812,\"w\":560,\"h\":97,\"abs_x\":618,\"abs_y\":1073}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":812,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1073}'\u003e2 pump output\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":831,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1092}'\u003eBMS volt-free output for common fault\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":851,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1112}'\u003eAnalog 0-10V output (mirrors analog input)\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":870,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1131}'\u003eOutput for solenoid valve available on request\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":890,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1151}'\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 bis_size='{\"x\":12,\"y\":924,\"w\":560,\"h\":22,\"abs_x\":618,\"abs_y\":1185}'\u003eCommon Applications\u003c\/h3\u003e\n\u003cul bis_size='{\"x\":12,\"y\":960,\"w\":560,\"h\":137,\"abs_x\":618,\"abs_y\":1221}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":960,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1221}'\u003eWater transfer\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":980,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1241}'\u003eTank fill\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1000,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1261}'\u003eSewage pump out\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1019,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1280}'\u003eStormwater pump out\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1039,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1300}'\u003ePressure boosting\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1058,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1319}'\u003eHot water recirculation\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1078,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1339}'\u003eChiller supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 bis_size='{\"x\":12,\"y\":1112,\"w\":560,\"h\":22,\"abs_x\":618,\"abs_y\":1373}'\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\" bis_size='{\"x\":12,\"y\":1145,\"w\":560,\"h\":106,\"abs_x\":618,\"abs_y\":1406}'\u003e\n\u003ctbody bis_size='{\"x\":15,\"y\":1148,\"w\":554,\"h\":100,\"abs_x\":621,\"abs_y\":1409}'\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":1148,\"w\":554,\"h\":23,\"abs_x\":621,\"abs_y\":1409}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":1148,\"w\":358,\"h\":23,\"abs_x\":621,\"abs_y\":1409}'\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":375,\"y\":1148,\"w\":193,\"h\":23,\"abs_x\":981,\"abs_y\":1409}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/e54d9eba0e4ab3257a8d93c1c52aaa5a00c4f088.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":377,\"y\":1150,\"w\":63,\"h\":19,\"abs_x\":983,\"abs_y\":1411}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":1174,\"w\":554,\"h\":23,\"abs_x\":621,\"abs_y\":1435}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":1174,\"w\":358,\"h\":23,\"abs_x\":621,\"abs_y\":1435}'\u003eProduct Guide\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":375,\"y\":1174,\"w\":193,\"h\":23,\"abs_x\":981,\"abs_y\":1435}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/0fde2ce949a2d88c6cf6a1fee529c31b7451011f.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":377,\"y\":1176,\"w\":63,\"h\":19,\"abs_x\":983,\"abs_y\":1437}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":1199,\"w\":554,\"h\":23,\"abs_x\":621,\"abs_y\":1460}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":1199,\"w\":358,\"h\":23,\"abs_x\":621,\"abs_y\":1460}'\u003eOperation Manual\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":375,\"y\":1199,\"w\":193,\"h\":23,\"abs_x\":981,\"abs_y\":1460}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/fdc519f87300ef0ff4be440566ef9e32807e6c39.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":377,\"y\":1201,\"w\":63,\"h\":19,\"abs_x\":983,\"abs_y\":1462}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":1225,\"w\":554,\"h\":23,\"abs_x\":621,\"abs_y\":1486}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":1225,\"w\":358,\"h\":23,\"abs_x\":621,\"abs_y\":1486}'\u003eQuick Start Guide\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":375,\"y\":1225,\"w\":193,\"h\":23,\"abs_x\":981,\"abs_y\":1486}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/c13fbd566a0336d45cfecb1d3ad611f50101893b.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":377,\"y\":1227,\"w\":63,\"h\":19,\"abs_x\":983,\"abs_y\":1488}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"-AA (1.6-2.5 Amp)","offer_id":45591624548461,"sku":"FPC-63243-AA","price":3120.48,"currency_code":"AUD","in_stock":true},{"title":"-A (2.5-4 Amp)","offer_id":45591624941677,"sku":"FPC-63243-A","price":3120.48,"currency_code":"AUD","in_stock":true},{"title":"-B (4-6 Amp)","offer_id":45591625334893,"sku":"FPC-63243-B","price":3120.48,"currency_code":"AUD","in_stock":true},{"title":"-BB (5.5-8 Amp)","offer_id":45591625728109,"sku":"FPC-63243-BB","price":3120.48,"currency_code":"AUD","in_stock":true},{"title":"-C (7-10 Amp)","offer_id":45591626121325,"sku":"FPC-63243-C","price":3120.48,"currency_code":"AUD","in_stock":true},{"title":"-D (9-13 Amp)","offer_id":45591626514541,"sku":"FPC-63243-D","price":3120.48,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPC-63243-product.webp?v=1785395454"},{"product_id":"hydrowhiz-submersible-level-controller-1ph-3-pump-fpc-63341-aa-d","title":"HydroWHIZ Submersible Level Controller (1PH 3 Pump) - FPC-63341-(AA-D)","description":"\u003cp bis_size='{\"x\":12,\"y\":9,\"w\":560,\"h\":195,\"abs_x\":618,\"abs_y\":270}'\u003eMATelec Australia's HydroWHIZ Controller has been designed with ease of use at the core of the system design. Building on the wealth of the pump control features in the Advanced controller, the HydroWHIZ brings these features into a new age with a colour touch screen interface and a streamlined setup process. In a world where information is power the HydroWHIZ has extensive time and date stamped alarms, logged data, trend graphs and diagnostic pages to provide the user with all the information required for optimisation and preventative maintenance. Featuring the flexibility of level, pressure and temperature system modes with a wide range of functions and protections, the HydroWHIZ controller is ideal for a vast range of applications including water transfer, stormwater and sewage pump out, pressure boosting, hot water circulation and chiller supply, to name a few.\u003c\/p\u003e\n\u003ch3 bis_size='{\"x\":12,\"y\":221,\"w\":560,\"h\":22,\"abs_x\":618,\"abs_y\":482}'\u003eProduct Details\u003c\/h3\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":255,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":516}'\u003eEnclosure\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":288,\"w\":560,\"h\":58,\"abs_x\":618,\"abs_y\":549}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":288,\"w\":520,\"h\":39,\"abs_x\":658,\"abs_y\":549}'\u003eIP56 rated, powder coated mild steel enclosure with inner door and removable gland plate\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":327,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":588}'\u003eEnclosure size: 400x400x250mm+\u003c\/li\u003e\n\u003cli\u003eEnclosure size will increase for high overload ratings and optional additions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":361,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":622}'\u003eProtection\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":394,\"w\":560,\"h\":97,\"abs_x\":618,\"abs_y\":655}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":394,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":655}'\u003ePad-lockable mains power isolator switch\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":414,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":675}'\u003eCircuit breaker protected low voltage control and input circuitry\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":434,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":695}'\u003eIndividual pump isolation\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":453,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":714}'\u003eContactor and thermal overload protection of pump motors\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":473,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":734}'\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":506,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":767}'\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":540,\"w\":560,\"h\":58,\"abs_x\":618,\"abs_y\":801}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":540,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":801}'\u003eHydroWHIZ colour touch screen HMI (see interface features)\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":560,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":821}'\u003eHydroWHIZ PCB control module\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":579,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":840}'\u003eVisual (strobe) and mutable audible (buzzer) alarms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":613,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":874}'\u003eInputs\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":646,\"w\":560,\"h\":97,\"abs_x\":618,\"abs_y\":907}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":646,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":907}'\u003eSingle phase (230Vac) power supply\u003cbr bis_size='{\"x\":273,\"y\":646,\"w\":0,\"h\":19,\"abs_x\":879,\"abs_y\":907}'\u003e\n\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":666,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":927}'\u003eAnalog 4-20mA input for level, pressure or temperature transducer\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":686,\"w\":520,\"h\":58,\"abs_x\":658,\"abs_y\":947}'\u003eUp to 8x digital 24Vdc inputs for low, stop, start, standby start and high float switches, pressure switches or thermostats, system enable\/disable input and a low flow switch\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":758,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":1019}'\u003eOutputs\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":792,\"w\":560,\"h\":97,\"abs_x\":618,\"abs_y\":1053}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":792,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1053}'\u003e3 pump output\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":812,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1073}'\u003eBMS volt-free output for common fault\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":831,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1092}'\u003eAnalog 0-10V output (mirrors analog input)\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":851,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1112}'\u003eOutput for solenoid valve available on request\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":870,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1131}'\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 bis_size='{\"x\":12,\"y\":904,\"w\":560,\"h\":22,\"abs_x\":618,\"abs_y\":1165}'\u003eCommon Applications\u003c\/h3\u003e\n\u003cul bis_size='{\"x\":12,\"y\":941,\"w\":560,\"h\":137,\"abs_x\":618,\"abs_y\":1202}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":941,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1202}'\u003eWater transfer\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":960,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1221}'\u003eTank fill\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":980,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1241}'\u003eSewage pump out\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1000,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1261}'\u003eStormwater pump out\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1019,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1280}'\u003ePressure boosting\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1039,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1300}'\u003eHot water recirculation\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1058,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1319}'\u003eChiller supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 bis_size='{\"x\":12,\"y\":1092,\"w\":560,\"h\":22,\"abs_x\":618,\"abs_y\":1353}'\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\" bis_size='{\"x\":12,\"y\":1125,\"w\":560,\"h\":106,\"abs_x\":618,\"abs_y\":1386}'\u003e\n\u003ctbody bis_size='{\"x\":15,\"y\":1128,\"w\":554,\"h\":100,\"abs_x\":621,\"abs_y\":1389}'\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":1128,\"w\":554,\"h\":23,\"abs_x\":621,\"abs_y\":1389}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":1128,\"w\":358,\"h\":23,\"abs_x\":621,\"abs_y\":1389}'\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":375,\"y\":1128,\"w\":193,\"h\":23,\"abs_x\":981,\"abs_y\":1389}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/e54d9eba0e4ab3257a8d93c1c52aaa5a00c4f088.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":377,\"y\":1130,\"w\":63,\"h\":19,\"abs_x\":983,\"abs_y\":1391}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":1154,\"w\":554,\"h\":23,\"abs_x\":621,\"abs_y\":1415}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":1154,\"w\":358,\"h\":23,\"abs_x\":621,\"abs_y\":1415}'\u003eProduct Guide\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":375,\"y\":1154,\"w\":193,\"h\":23,\"abs_x\":981,\"abs_y\":1415}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/0fde2ce949a2d88c6cf6a1fee529c31b7451011f.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":377,\"y\":1156,\"w\":63,\"h\":19,\"abs_x\":983,\"abs_y\":1417}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":1180,\"w\":554,\"h\":23,\"abs_x\":621,\"abs_y\":1441}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":1180,\"w\":358,\"h\":23,\"abs_x\":621,\"abs_y\":1441}'\u003eOperation Manual\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":375,\"y\":1180,\"w\":193,\"h\":23,\"abs_x\":981,\"abs_y\":1441}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/fdc519f87300ef0ff4be440566ef9e32807e6c39.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":377,\"y\":1182,\"w\":63,\"h\":19,\"abs_x\":983,\"abs_y\":1443}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":1205,\"w\":554,\"h\":23,\"abs_x\":621,\"abs_y\":1466}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":1205,\"w\":358,\"h\":23,\"abs_x\":621,\"abs_y\":1466}'\u003eQuick Start Guide\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":375,\"y\":1205,\"w\":193,\"h\":23,\"abs_x\":981,\"abs_y\":1466}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/c13fbd566a0336d45cfecb1d3ad611f50101893b.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":377,\"y\":1207,\"w\":63,\"h\":19,\"abs_x\":983,\"abs_y\":1468}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"-AA (1.6-2.5 Amp)","offer_id":45591611572333,"sku":"FPC-63341-AA","price":3578.96,"currency_code":"AUD","in_stock":true},{"title":"-A (2.5-4 Amp)","offer_id":45591611605101,"sku":"FPC-63341-A","price":3578.96,"currency_code":"AUD","in_stock":true},{"title":"-B (4-6 Amp)","offer_id":45591611637869,"sku":"FPC-63341-B","price":3578.96,"currency_code":"AUD","in_stock":true},{"title":"-BB (5.5-8 Amp)","offer_id":45591611670637,"sku":"FPC-63341-BB","price":3578.96,"currency_code":"AUD","in_stock":true},{"title":"-C (7-10 Amp)","offer_id":45591611703405,"sku":"FPC-63341-C","price":3578.96,"currency_code":"AUD","in_stock":true},{"title":"-D (9-13 Amp)","offer_id":45591611736173,"sku":"FPC-63341-D","price":3578.96,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPC-63341-product.webp?v=1785395770"},{"product_id":"hydrowhiz-submersible-level-controller-3ph-3-pump-fpc-63343-aa-d","title":"HydroWHIZ Submersible Level Controller (3PH 3 Pump) - FPC-63343-(AA-D)","description":"\u003cp bis_size='{\"x\":12,\"y\":9,\"w\":560,\"h\":195,\"abs_x\":618,\"abs_y\":270}'\u003eMATelec Australia's HydroWHIZ Controller has been designed with ease of use at the core of the system design. Building on the wealth of the pump control features in the Advanced controller, the HydroWHIZ brings these features into a new age with a colour touch screen interface and a streamlined setup process. In a world where information is power the HydroWHIZ has extensive time and date stamped alarms, logged data, trend graphs and diagnostic pages to provide the user with all the information required for optimisation and preventative maintenance. Featuring the flexibility of level, pressure and temperature system modes with a wide range of functions and protections, the HydroWHIZ controller is ideal for a vast range of applications including water transfer, stormwater and sewage pump out, pressure boosting, hot water circulation and chiller supply, to name a few.\u003c\/p\u003e\n\u003ch3 bis_size='{\"x\":12,\"y\":221,\"w\":560,\"h\":22,\"abs_x\":618,\"abs_y\":482}'\u003eProduct Details\u003c\/h3\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":255,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":516}'\u003eEnclosure\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":288,\"w\":560,\"h\":58,\"abs_x\":618,\"abs_y\":549}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":288,\"w\":520,\"h\":39,\"abs_x\":658,\"abs_y\":549}'\u003eIP56 rated, powder coated mild steel enclosure with inner door and removable gland plate\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":327,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":588}'\u003eEnclosure size: 400x400x250mm+\u003c\/li\u003e\n\u003cli\u003eEnclosure size will increase for high overload ratings and optional additions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":361,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":622}'\u003eProtection\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":394,\"w\":560,\"h\":97,\"abs_x\":618,\"abs_y\":655}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":394,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":655}'\u003ePad-lockable mains power isolator switch\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":414,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":675}'\u003eCircuit breaker protected low voltage control and input circuitry\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":434,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":695}'\u003eIndividual pump isolation\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":453,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":714}'\u003eContactor and thermal overload protection of pump motors\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":473,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":734}'\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":506,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":767}'\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":540,\"w\":560,\"h\":58,\"abs_x\":618,\"abs_y\":801}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":540,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":801}'\u003eHydroWHIZ colour touch screen HMI (see interface features)\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":560,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":821}'\u003eHydroWHIZ PCB control module\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":579,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":840}'\u003eVisual (strobe) and mutable audible (buzzer) alarms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":613,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":874}'\u003eInputs\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":646,\"w\":560,\"h\":117,\"abs_x\":618,\"abs_y\":907}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":646,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":907}'\u003eThree phase (400Vac) power supply\u003cbr bis_size='{\"x\":270,\"y\":646,\"w\":0,\"h\":19,\"abs_x\":876,\"abs_y\":907}'\u003e\n\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":666,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":927}'\u003eAnalog 4-20mA input for level, pressure or temperature transducer\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":686,\"w\":520,\"h\":58,\"abs_x\":658,\"abs_y\":947}'\u003eUp to 8x digital 24Vdc inputs for low, stop, start, standby start and high float switches, pressure switches or thermostats, system enable\/disable input and a low flow switch\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":744,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1005}'\u003eThermal switch inputs per pump (three phase only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":778,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":1039}'\u003eOutputs\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":812,\"w\":560,\"h\":97,\"abs_x\":618,\"abs_y\":1073}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":812,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1073}'\u003e3 pump output\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":831,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1092}'\u003eBMS volt-free output for common fault\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":851,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1112}'\u003eAnalog 0-10V output (mirrors analog input)\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":870,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1131}'\u003eOutput for solenoid valve available on request\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":890,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1151}'\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 bis_size='{\"x\":12,\"y\":924,\"w\":560,\"h\":22,\"abs_x\":618,\"abs_y\":1185}'\u003eCommon Applications\u003c\/h3\u003e\n\u003cul bis_size='{\"x\":12,\"y\":960,\"w\":560,\"h\":137,\"abs_x\":618,\"abs_y\":1221}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":960,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1221}'\u003eWater transfer\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":980,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1241}'\u003eTank fill\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1000,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1261}'\u003eSewage pump out\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1019,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1280}'\u003eStormwater pump out\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1039,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1300}'\u003ePressure boosting\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1058,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1319}'\u003eHot water recirculation\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1078,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1339}'\u003eChiller supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 bis_size='{\"x\":12,\"y\":1112,\"w\":560,\"h\":22,\"abs_x\":618,\"abs_y\":1373}'\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\" bis_size='{\"x\":12,\"y\":1145,\"w\":560,\"h\":106,\"abs_x\":618,\"abs_y\":1406}'\u003e\n\u003ctbody bis_size='{\"x\":15,\"y\":1148,\"w\":554,\"h\":100,\"abs_x\":621,\"abs_y\":1409}'\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":1148,\"w\":554,\"h\":23,\"abs_x\":621,\"abs_y\":1409}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":1148,\"w\":358,\"h\":23,\"abs_x\":621,\"abs_y\":1409}'\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":375,\"y\":1148,\"w\":193,\"h\":23,\"abs_x\":981,\"abs_y\":1409}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/e54d9eba0e4ab3257a8d93c1c52aaa5a00c4f088.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":377,\"y\":1150,\"w\":63,\"h\":19,\"abs_x\":983,\"abs_y\":1411}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":1174,\"w\":554,\"h\":23,\"abs_x\":621,\"abs_y\":1435}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":1174,\"w\":358,\"h\":23,\"abs_x\":621,\"abs_y\":1435}'\u003eProduct Guide\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":375,\"y\":1174,\"w\":193,\"h\":23,\"abs_x\":981,\"abs_y\":1435}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/0fde2ce949a2d88c6cf6a1fee529c31b7451011f.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":377,\"y\":1176,\"w\":63,\"h\":19,\"abs_x\":983,\"abs_y\":1437}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":1199,\"w\":554,\"h\":23,\"abs_x\":621,\"abs_y\":1460}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":1199,\"w\":358,\"h\":23,\"abs_x\":621,\"abs_y\":1460}'\u003eOperation Manual\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":375,\"y\":1199,\"w\":193,\"h\":23,\"abs_x\":981,\"abs_y\":1460}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/fdc519f87300ef0ff4be440566ef9e32807e6c39.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":377,\"y\":1201,\"w\":63,\"h\":19,\"abs_x\":983,\"abs_y\":1462}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":1225,\"w\":554,\"h\":23,\"abs_x\":621,\"abs_y\":1486}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":1225,\"w\":358,\"h\":23,\"abs_x\":621,\"abs_y\":1486}'\u003eQuick Start Guide\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":375,\"y\":1225,\"w\":193,\"h\":23,\"abs_x\":981,\"abs_y\":1486}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/c13fbd566a0336d45cfecb1d3ad611f50101893b.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":377,\"y\":1227,\"w\":63,\"h\":19,\"abs_x\":983,\"abs_y\":1488}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"-AA (1.6-2.5 Amp)","offer_id":45591627366509,"sku":"FPC-63343-AA","price":3769.04,"currency_code":"AUD","in_stock":true},{"title":"-A (2.5-4 Amp)","offer_id":45591627759725,"sku":"FPC-63343-A","price":3769.04,"currency_code":"AUD","in_stock":true},{"title":"-B (4-6 Amp)","offer_id":45591628152941,"sku":"FPC-63343-B","price":3769.04,"currency_code":"AUD","in_stock":true},{"title":"-BB (5.5-8 Amp)","offer_id":45591628546157,"sku":"FPC-63343-BB","price":3769.04,"currency_code":"AUD","in_stock":true},{"title":"-C (7-10 Amp)","offer_id":45591628939373,"sku":"FPC-63343-C","price":3769.04,"currency_code":"AUD","in_stock":true},{"title":"-D (9-13 Amp)","offer_id":45591629332589,"sku":"FPC-63343-D","price":3769.04,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPC-63343-product.webp?v=1785397859"},{"product_id":"hydrowhiz-submersible-level-controller-1ph-4-pump-fpc-63441-aa-d","title":"HydroWHIZ Submersible Level Controller (1PH 4 Pump) - FPC-63441-(AA-D)","description":"\u003cp\u003eMATelec Australia's HydroWHIZ Controller has been designed with ease of use at the core of the system design. Building on the wealth of the pump control features in the Advanced controller, the HydroWHIZ brings these features into a new age with a colour touch screen interface and a streamlined setup process. In a world where information is power the HydroWHIZ has extensive time and date stamped alarms, logged data, trend graphs and diagnostic pages to provide the user with all the information required for optimisation and preventative maintenance. Featuring the flexibility of level, pressure and temperature system modes with a wide range of functions and protections, the HydroWHIZ controller is ideal for a vast range of applications including water transfer, stormwater and sewage pump out, pressure boosting, hot water circulation and chiller supply, to name a few.\u003c\/p\u003e\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003ch4\u003eEnclosure\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIP56 rated, powder coated mild steel enclosure with inner door and removable gland plate\u003c\/li\u003e\n\u003cli\u003eEnclosure size: 400x400x250mm+\u003c\/li\u003e\n\u003cli\u003eEnclosure size will increase for high overload ratings and optional additions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProtection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003ePad-lockable mains power isolator switch\u003c\/li\u003e\n\u003cli\u003eCircuit breaker protected low voltage control and input circuitry\u003c\/li\u003e\n\u003cli\u003eIndividual pump isolation\u003c\/li\u003e\n\u003cli\u003eContactor and thermal overload protection of pump motors\u003c\/li\u003e\n\u003cli\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHydroWHIZ colour touch screen HMI (see interface features)\u003c\/li\u003e\n\u003cli\u003eHydroWHIZ PCB control module\u003c\/li\u003e\n\u003cli\u003eVisual (strobe) and mutable audible (buzzer) alarms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSingle phase (230Vac) power supply\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eAnalog 4-20mA input for level, pressure or temperature transducer\u003c\/li\u003e\n\u003cli\u003eUp to 8x digital 24Vdc inputs for low, stop, start, standby start and high float switches, pressure switches or thermostats, system enable\/disable input and a low flow switch\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOutputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e4 pump output\u003c\/li\u003e\n\u003cli\u003eBMS volt-free output for common fault\u003c\/li\u003e\n\u003cli\u003eAnalog 0-10V output (mirrors analog input)\u003c\/li\u003e\n\u003cli\u003eOutput for solenoid valve available on request\u003c\/li\u003e\n\u003cli\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommon Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWater transfer\u003c\/li\u003e\n\u003cli\u003eTank fill\u003c\/li\u003e\n\u003cli\u003eSewage pump out\u003c\/li\u003e\n\u003cli\u003eStormwater pump out\u003c\/li\u003e\n\u003cli\u003ePressure boosting\u003c\/li\u003e\n\u003cli\u003eHot water recirculation\u003c\/li\u003e\n\u003cli\u003eChiller supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/e54d9eba0e4ab3257a8d93c1c52aaa5a00c4f088.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/0fde2ce949a2d88c6cf6a1fee529c31b7451011f.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation Manual\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/fdc519f87300ef0ff4be440566ef9e32807e6c39.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuick Start Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/c13fbd566a0336d45cfecb1d3ad611f50101893b.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"-AA (1.6-2.5 Amp)","offer_id":45591611834477,"sku":"FPC-63441-AA","price":4488.0,"currency_code":"AUD","in_stock":true},{"title":"-A (2.5-4 Amp)","offer_id":45591611867245,"sku":"FPC-63441-A","price":4488.0,"currency_code":"AUD","in_stock":true},{"title":"-B (4-6 Amp)","offer_id":45591611900013,"sku":"FPC-63441-B","price":4488.0,"currency_code":"AUD","in_stock":true},{"title":"-BB (5.5-8 Amp)","offer_id":45591611932781,"sku":"FPC-63441-BB","price":4488.0,"currency_code":"AUD","in_stock":true},{"title":"-C (7-10 Amp)","offer_id":45591611965549,"sku":"FPC-63441-C","price":4488.0,"currency_code":"AUD","in_stock":true},{"title":"-D (9-13 Amp)","offer_id":45591611998317,"sku":"FPC-63441-D","price":4488.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPC-63441-product.webp?v=1785399085"},{"product_id":"hydrowhiz-submersible-level-controller-3ph-4-pump-fpc-63443-aa-d","title":"HydroWHIZ Submersible Level Controller (3PH 4 Pump) - FPC-63443-(AA-D)","description":"\u003cp bis_size='{\"x\":12,\"y\":9,\"w\":560,\"h\":195,\"abs_x\":618,\"abs_y\":270}'\u003eMATelec Australia's HydroWHIZ Controller has been designed with ease of use at the core of the system design. Building on the wealth of the pump control features in the Advanced controller, the HydroWHIZ brings these features into a new age with a colour touch screen interface and a streamlined setup process. In a world where information is power the HydroWHIZ has extensive time and date stamped alarms, logged data, trend graphs and diagnostic pages to provide the user with all the information required for optimisation and preventative maintenance. Featuring the flexibility of level, pressure and temperature system modes with a wide range of functions and protections, the HydroWHIZ controller is ideal for a vast range of applications including water transfer, stormwater and sewage pump out, pressure boosting, hot water circulation and chiller supply, to name a few.\u003c\/p\u003e\n\u003ch3 bis_size='{\"x\":12,\"y\":221,\"w\":560,\"h\":22,\"abs_x\":618,\"abs_y\":482}'\u003eProduct Details\u003c\/h3\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":255,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":516}'\u003eEnclosure\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":288,\"w\":560,\"h\":58,\"abs_x\":618,\"abs_y\":549}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":288,\"w\":520,\"h\":39,\"abs_x\":658,\"abs_y\":549}'\u003eIP56 rated, powder coated mild steel enclosure with inner door and removable gland plate\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":327,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":588}'\u003eEnclosure size: 500x500x350mm+\u003c\/li\u003e\n\u003cli\u003eEnclosure size will increase for high overload ratings and optional additions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":361,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":622}'\u003eProtection\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":394,\"w\":560,\"h\":97,\"abs_x\":618,\"abs_y\":655}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":394,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":655}'\u003ePad-lockable mains power isolator switch\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":414,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":675}'\u003eCircuit breaker protected low voltage control and input circuitry\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":434,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":695}'\u003eIndividual pump isolation\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":453,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":714}'\u003eContactor and thermal overload protection of pump motors\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":473,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":734}'\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":506,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":767}'\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":540,\"w\":560,\"h\":58,\"abs_x\":618,\"abs_y\":801}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":540,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":801}'\u003eHydroWHIZ colour touch screen HMI (see interface features)\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":560,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":821}'\u003eHydroWHIZ PCB control module\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":579,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":840}'\u003eVisual (strobe) and mutable audible (buzzer) alarms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":613,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":874}'\u003eInputs\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":646,\"w\":560,\"h\":117,\"abs_x\":618,\"abs_y\":907}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":646,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":907}'\u003eThree phase (400Vac) power supply\u003cbr bis_size='{\"x\":270,\"y\":646,\"w\":0,\"h\":19,\"abs_x\":876,\"abs_y\":907}'\u003e\n\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":666,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":927}'\u003eAnalog 4-20mA input for level, pressure or temperature transducer\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":686,\"w\":520,\"h\":58,\"abs_x\":658,\"abs_y\":947}'\u003eUp to 8x digital 24Vdc inputs for low, stop, start, standby start and high float switches, pressure switches or thermostats, system enable\/disable input and a low flow switch\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":744,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1005}'\u003eThermal switch inputs per pump (three phase only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":778,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":1039}'\u003eOutputs\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":812,\"w\":560,\"h\":97,\"abs_x\":618,\"abs_y\":1073}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":812,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1073}'\u003e4 pump output\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":831,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1092}'\u003eBMS volt-free output for common fault\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":851,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1112}'\u003eAnalog 0-10V output (mirrors analog input)\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":870,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1131}'\u003eOutput for solenoid valve available on request\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":890,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1151}'\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 bis_size='{\"x\":12,\"y\":924,\"w\":560,\"h\":22,\"abs_x\":618,\"abs_y\":1185}'\u003eCommon Applications\u003c\/h3\u003e\n\u003cul bis_size='{\"x\":12,\"y\":960,\"w\":560,\"h\":137,\"abs_x\":618,\"abs_y\":1221}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":960,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1221}'\u003eWater transfer\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":980,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1241}'\u003eTank fill\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1000,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1261}'\u003eSewage pump out\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1019,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1280}'\u003eStormwater pump out\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1039,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1300}'\u003ePressure boosting\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1058,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1319}'\u003eHot water recirculation\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1078,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1339}'\u003eChiller supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 bis_size='{\"x\":12,\"y\":1112,\"w\":560,\"h\":22,\"abs_x\":618,\"abs_y\":1373}'\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\" bis_size='{\"x\":12,\"y\":1145,\"w\":560,\"h\":106,\"abs_x\":618,\"abs_y\":1406}'\u003e\n\u003ctbody bis_size='{\"x\":15,\"y\":1148,\"w\":554,\"h\":100,\"abs_x\":621,\"abs_y\":1409}'\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":1148,\"w\":554,\"h\":23,\"abs_x\":621,\"abs_y\":1409}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":1148,\"w\":358,\"h\":23,\"abs_x\":621,\"abs_y\":1409}'\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":375,\"y\":1148,\"w\":193,\"h\":23,\"abs_x\":981,\"abs_y\":1409}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/e54d9eba0e4ab3257a8d93c1c52aaa5a00c4f088.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":377,\"y\":1150,\"w\":63,\"h\":19,\"abs_x\":983,\"abs_y\":1411}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":1174,\"w\":554,\"h\":23,\"abs_x\":621,\"abs_y\":1435}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":1174,\"w\":358,\"h\":23,\"abs_x\":621,\"abs_y\":1435}'\u003eProduct Guide\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":375,\"y\":1174,\"w\":193,\"h\":23,\"abs_x\":981,\"abs_y\":1435}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/0fde2ce949a2d88c6cf6a1fee529c31b7451011f.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":377,\"y\":1176,\"w\":63,\"h\":19,\"abs_x\":983,\"abs_y\":1437}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":1199,\"w\":554,\"h\":23,\"abs_x\":621,\"abs_y\":1460}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":1199,\"w\":358,\"h\":23,\"abs_x\":621,\"abs_y\":1460}'\u003eOperation Manual\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":375,\"y\":1199,\"w\":193,\"h\":23,\"abs_x\":981,\"abs_y\":1460}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/fdc519f87300ef0ff4be440566ef9e32807e6c39.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":377,\"y\":1201,\"w\":63,\"h\":19,\"abs_x\":983,\"abs_y\":1462}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":1225,\"w\":554,\"h\":23,\"abs_x\":621,\"abs_y\":1486}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":1225,\"w\":358,\"h\":23,\"abs_x\":621,\"abs_y\":1486}'\u003eQuick Start Guide\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":375,\"y\":1225,\"w\":193,\"h\":23,\"abs_x\":981,\"abs_y\":1486}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/c13fbd566a0336d45cfecb1d3ad611f50101893b.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":377,\"y\":1227,\"w\":63,\"h\":19,\"abs_x\":983,\"abs_y\":1488}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"-AA (1.6-2.5 Amp)","offer_id":45591630413933,"sku":"FPC-63443-AA","price":4641.12,"currency_code":"AUD","in_stock":true},{"title":"-A (2.5-4 Amp)","offer_id":45591630446701,"sku":"FPC-63443-A","price":4641.12,"currency_code":"AUD","in_stock":true},{"title":"-B (4-6 Amp)","offer_id":45591630479469,"sku":"FPC-63443-B","price":4641.12,"currency_code":"AUD","in_stock":true},{"title":"-BB (5.5-8 Amp)","offer_id":45591630512237,"sku":"FPC-63443-BB","price":4641.12,"currency_code":"AUD","in_stock":true},{"title":"-C (7-10 Amp)","offer_id":45591630545005,"sku":"FPC-63443-C","price":4641.12,"currency_code":"AUD","in_stock":true},{"title":"-D (9-13 Amp)","offer_id":45591630577773,"sku":"FPC-63443-D","price":4641.12,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPC-63443-product.webp?v=1785399898"},{"product_id":"hydrostart-hwc-1ph-2-pump-0-1-16a-fpc-81241","title":"HydroSTART - HWC 1PH 2 Pump 0.1-16A - FPC-81241-HWC","description":"\u003cp bis_size='{\"x\":12,\"y\":9,\"w\":560,\"h\":78,\"abs_x\":618,\"abs_y\":270}'\u003eMATelec Australia's HydroSTART Controller brings the features of the standard single and dual pump controllers into a new age with a redesigned capacitive touch keypad and control module with pump current sensing, providing wide range electronic overload protection which now functions with both single and three phase pumps.\u003c\/p\u003e\n\u003cp bis_size='{\"x\":12,\"y\":103,\"w\":560,\"h\":58,\"abs_x\":618,\"abs_y\":364}'\u003eAdditional control inputs and functionality have been incorporated into the new design to enhance the controller's flexibility and cover an even wider range of pumping applications. The HydroSTART is the new standard for pump controls.\u003c\/p\u003e\n\u003ch3 bis_size='{\"x\":12,\"y\":178,\"w\":560,\"h\":22,\"abs_x\":618,\"abs_y\":439}'\u003eProduct Details\u003c\/h3\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":212,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":473}'\u003eEnclosure\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":245,\"w\":560,\"h\":58,\"abs_x\":618,\"abs_y\":506}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":245,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":506}'\u003eEnclosure size: 400x300x150mm\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":265,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":526}'\u003ePowder coated mild steel enclosure with removable gland plate\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":285,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":546}'\u003e\u003cspan bis_size='{\"x\":52,\"y\":285,\"w\":148,\"h\":19,\"abs_x\":658,\"abs_y\":546}'\u003eIP54 rated single door for indoor mounting (single door version) \u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":318,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":579}'\u003eProtection\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":352,\"w\":560,\"h\":137,\"abs_x\":618,\"abs_y\":613}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":352,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":613}'\u003eSelectable overload range: 0.1-6 Amp, 5-16 Amp\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":371,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":632}'\u003ePad-lockable mains power isolator switch\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":391,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":652}'\u003eLow voltage control and input circuitry\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":410,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":671}'\u003eIndividual pump circuit breaker protection\/isolation\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":430,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":691}'\u003eContactors for pump switching (three-phase panels)\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":450,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":711}'\u003eElectronic short and overload protection of alarms\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":469,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":730}'\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":503,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":764}'\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":536,\"w\":560,\"h\":117,\"abs_x\":618,\"abs_y\":797}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":536,\"w\":520,\"h\":58,\"abs_x\":658,\"abs_y\":797}'\u003eHydroSTART single or dual pump capacitive touch keypad interface:\n\u003cul bis_size='{\"x\":52,\"y\":556,\"w\":520,\"h\":39,\"abs_x\":658,\"abs_y\":817}'\u003e\n\u003cli bis_size='{\"x\":92,\"y\":556,\"w\":480,\"h\":19,\"abs_x\":698,\"abs_y\":817}'\u003eIndicator lights for system and pump status\u003c\/li\u003e\n\u003cli bis_size='{\"x\":92,\"y\":576,\"w\":480,\"h\":19,\"abs_x\":698,\"abs_y\":837}'\u003eButtons for alarm mute\/reset and pump mode selection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":595,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":856}'\u003eHydroSTART PCB control module with dipswitches for adjusting configuration\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":615,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":876}'\u003eVisual (strobe) and audible (buzzer) alarms\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":634,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":895}'\u003ePump current sensing providing adjustable overload \u0026amp; other protections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":668,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":929}'\u003eInputs\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":702,\"w\":560,\"h\":58,\"abs_x\":618,\"abs_y\":963}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":702,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":963}'\u003eSingle phase (230Vac) power supply\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":721,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":982}'\u003eDigital input for thermostat and time clock\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":741,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1002}'\u003eHot water terminal set up, with volt free BMS outputs and system enable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":774,\"w\":560,\"h\":19,\"abs_x\":618,\"abs_y\":1035}'\u003eOutputs\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":808,\"w\":560,\"h\":58,\"abs_x\":618,\"abs_y\":1069}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":808,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1069}'\u003e2x pump supply outputs\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":828,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1089}'\u003eBMS volt-free output for common fault\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":847,\"w\":520,\"h\":19,\"abs_x\":658,\"abs_y\":1108}'\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 bis_size='{\"x\":12,\"y\":881,\"w\":560,\"h\":22,\"abs_x\":618,\"abs_y\":1142}'\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\" bis_size='{\"x\":12,\"y\":914,\"w\":560,\"h\":106,\"abs_x\":618,\"abs_y\":1175}'\u003e\n\u003ctbody bis_size='{\"x\":15,\"y\":917,\"w\":554,\"h\":100,\"abs_x\":621,\"abs_y\":1178}'\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":917,\"w\":554,\"h\":23,\"abs_x\":621,\"abs_y\":1178}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":917,\"w\":358,\"h\":23,\"abs_x\":621,\"abs_y\":1178}'\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":375,\"y\":917,\"w\":193,\"h\":23,\"abs_x\":981,\"abs_y\":1178}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/08f5a11902b64509503920491cac62bb60c5a92e.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":377,\"y\":919,\"w\":63,\"h\":19,\"abs_x\":983,\"abs_y\":1180}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":943,\"w\":554,\"h\":23,\"abs_x\":621,\"abs_y\":1204}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":943,\"w\":358,\"h\":23,\"abs_x\":621,\"abs_y\":1204}'\u003eProduct Guide\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":375,\"y\":943,\"w\":193,\"h\":23,\"abs_x\":981,\"abs_y\":1204}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/0fde2ce949a2d88c6cf6a1fee529c31b7451011f.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":377,\"y\":945,\"w\":63,\"h\":19,\"abs_x\":983,\"abs_y\":1206}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":968,\"w\":554,\"h\":23,\"abs_x\":621,\"abs_y\":1229}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":968,\"w\":358,\"h\":23,\"abs_x\":621,\"abs_y\":1229}'\u003eOperation Manual\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":375,\"y\":968,\"w\":193,\"h\":23,\"abs_x\":981,\"abs_y\":1229}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/2bd7c38a494e8c01cbfb4d1f1189308a61b1a103.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":377,\"y\":970,\"w\":63,\"h\":19,\"abs_x\":983,\"abs_y\":1231}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":994,\"w\":554,\"h\":23,\"abs_x\":621,\"abs_y\":1255}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":994,\"w\":358,\"h\":23,\"abs_x\":621,\"abs_y\":1255}'\u003eQuick Start Guide\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":375,\"y\":994,\"w\":193,\"h\":23,\"abs_x\":981,\"abs_y\":1255}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/85a2dcb6f7983bd6b95a1a57c28f6e6839cb322b.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":377,\"y\":996,\"w\":63,\"h\":19,\"abs_x\":983,\"abs_y\":1257}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"0.1-6amp","offer_id":45615482077293,"sku":"FPC-81241-HWC-1","price":1654.4,"currency_code":"AUD","in_stock":true},{"title":"5-16 amp","offer_id":45615482110061,"sku":"FPC-81241-HWC-2","price":1654.4,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPC-81241-product.webp?v=1785465493"},{"product_id":"hydrostart-hwc-1ph-2-pump-0-1-10a-fpc-81241-qp","title":"HydroSTART - HWC 1PH 2 Pump 0.1-10A c\/w Quick Plug - FPC-81241-HWC\/QP","description":"\u003cp\u003eMATelec Australia's HydroSTART Controller brings the features of the standard single and dual pump controllers into a new age with a redesigned capacitive touch keypad and control module with pump current sensing, providing wide range electronic overload protection which now functions with both single and three phase pumps.\u003c\/p\u003e\n\u003cp\u003eAdditional control inputs and functionality have been incorporated into the new design to enhance the controller's flexibility and cover an even wider range of pumping applications. The HydroSTART is the new standard for pump controls.\u003c\/p\u003e\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003ch4\u003eEnclosure\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eEnclosure size: 400x300x150mm\u003c\/li\u003e\n\u003cli\u003ePowder coated mild steel enclosure with removable gland plate\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIP54 rated single door for indoor mounting (single door version) \u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProtection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSelectable overload range: 0.1-6 Amp, 5-16 Amp\u003c\/li\u003e\n\u003cli\u003ePad-lockable mains power isolator switch\u003c\/li\u003e\n\u003cli\u003eLow voltage control and input circuitry\u003c\/li\u003e\n\u003cli\u003eIndividual pump circuit breaker protection\/isolation\u003c\/li\u003e\n\u003cli\u003eContactors for pump switching (three-phase panels)\u003c\/li\u003e\n\u003cli\u003eElectronic short and overload protection of alarms\u003c\/li\u003e\n\u003cli\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHydroSTART single or dual pump capacitive touch keypad interface:\n\u003cul\u003e\n\u003cli\u003eIndicator lights for system and pump status\u003c\/li\u003e\n\u003cli\u003eButtons for alarm mute\/reset and pump mode selection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eHydroSTART PCB control module with dipswitches for adjusting configuration\u003c\/li\u003e\n\u003cli\u003eVisual (strobe) and audible (buzzer) alarms\u003c\/li\u003e\n\u003cli\u003ePump current sensing providing adjustable overload \u0026amp; other protections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSingle phase (230Vac) power supply\u003c\/li\u003e\n\u003cli\u003eDigital input for thermostat and time clock\u003c\/li\u003e\n\u003cli\u003eHot water terminal set up, with volt free BMS outputs and system enable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOutputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e2x pump supply outputs\u003c\/li\u003e\n\u003cli\u003eBMS volt-free output for common fault\u003c\/li\u003e\n\u003cli\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/08f5a11902b64509503920491cac62bb60c5a92e.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/0fde2ce949a2d88c6cf6a1fee529c31b7451011f.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation Manual\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/2bd7c38a494e8c01cbfb4d1f1189308a61b1a103.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuick Start Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/85a2dcb6f7983bd6b95a1a57c28f6e6839cb322b.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"0.1-6amp","offer_id":45615479881837,"sku":"FPC-81241-HWC\/QP-1","price":1694.0,"currency_code":"AUD","in_stock":true},{"title":"5-16 amp","offer_id":45615479914605,"sku":"FPC-81241-HWC\/QP-2","price":1694.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPC-81241-QP-product.webp?v=1785465773"},{"product_id":"hydrostart-hwc-1ph-2-pump-0-1-16a-c-w-time-clock-fpc-81241","title":"HydroSTART - HWC 1PH 2 Pump 0.1-16A c\/w Time Clock - FPC-81241-HWC\/TC","description":"\u003cp\u003eMATelec Australia's HydroSTART Controller brings the features of the standard single and dual pump controllers into a new age with a redesigned capacitive touch keypad and control module with pump current sensing, providing wide range electronic overload protection which now functions with both single and three phase pumps.\u003c\/p\u003e\n\u003cp\u003eAdditional control inputs and functionality have been incorporated into the new design to enhance the controller's flexibility and cover an even wider range of pumping applications. The HydroSTART is the new standard for pump controls.\u003c\/p\u003e\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003ch4\u003eEnclosure\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eEnclosure size: 400x300x150mm\u003c\/li\u003e\n\u003cli\u003ePowder coated mild steel enclosure with removable gland plate\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIP54 rated single door\u003cspan\u003e for indoor mounting (single door version) \u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProtection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSelectable overload range: 0.1-6 Amp, 5-16 Amp\u003c\/li\u003e\n\u003cli\u003ePad-lockable mains power isolator switch\u003c\/li\u003e\n\u003cli\u003eLow voltage control and input circuitry\u003c\/li\u003e\n\u003cli\u003eIndividual pump circuit breaker protection\/isolation\u003c\/li\u003e\n\u003cli\u003eContactors for pump switching (three-phase panels)\u003c\/li\u003e\n\u003cli\u003eElectronic short and overload protection of alarms\u003c\/li\u003e\n\u003cli\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHydroSTART single or dual pump capacitive touch keypad interface:\n\u003cul\u003e\n\u003cli\u003eIndicator lights for system and pump status\u003c\/li\u003e\n\u003cli\u003eButtons for alarm mute\/reset and pump mode selection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eHydroSTART PCB control module with dipswitches for adjusting configuration\u003c\/li\u003e\n\u003cli\u003eVisual (strobe) and audible (buzzer) alarms\u003c\/li\u003e\n\u003cli\u003ePump current sensing providing adjustable overload \u0026amp; other protections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSingle phase (230Vac) power supply\u003c\/li\u003e\n\u003cli\u003eDigital input for thermostat and time clock\u003c\/li\u003e\n\u003cli\u003eHot water terminal set up, with volt free BMS outputs and system enable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOutputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e2x pump supply outputs\u003c\/li\u003e\n\u003cli\u003eBMS volt-free output for common fault\u003c\/li\u003e\n\u003cli\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/08f5a11902b64509503920491cac62bb60c5a92e.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/0fde2ce949a2d88c6cf6a1fee529c31b7451011f.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation Manual\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/2bd7c38a494e8c01cbfb4d1f1189308a61b1a103.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuick Start Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/85a2dcb6f7983bd6b95a1a57c28f6e6839cb322b.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"0.1-6amp","offer_id":45615477948525,"sku":"FPC-81241-HWC\/TC-1","price":1749.44,"currency_code":"AUD","in_stock":true},{"title":"5-16 amp","offer_id":45615477981293,"sku":"FPC-81241-HWC\/TC-2","price":1749.44,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPC-81241-TC-product.webp?v=1785466240"},{"product_id":"hydrostart-hwc-1ph-2-pump-0-1-16a-c-w-id-fpc-82241","title":"HydroSTART - HWC 1PH 2 Pump 0.1-16A c\/w ID - FPC-82241-HWC","description":"\u003cp\u003eMATelec Australia's HydroSTART Controller brings the features of the standard single and dual pump controllers into a new age with a redesigned capacitive touch keypad and control module with pump current sensing, providing wide range electronic overload protection which now functions with both single and three phase pumps.\u003c\/p\u003e\n\u003cp\u003eAdditional control inputs and functionality have been incorporated into the new design to enhance the controller's flexibility and cover an even wider range of pumping applications. The HydroSTART is the new standard for pump controls.\u003c\/p\u003e\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003ch4\u003eEnclosure\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eEnclosure size: 400x400x200mm\u003c\/li\u003e\n\u003cli\u003ePowder coated mild steel enclosure with removable gland plate\u003c\/li\u003e\n\u003cli\u003eIP56 rated with inner door for outdoor mounting (inner door version)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProtection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSelectable overload range: 0.1-6 Amp, 5-16 Amp\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003ePad-lockable mains power isolator switch\u003c\/li\u003e\n\u003cli\u003eLow voltage control and input circuitry\u003c\/li\u003e\n\u003cli\u003eIndividual pump circuit breaker protection\/isolation\u003c\/li\u003e\n\u003cli\u003eContactors for pump switching (three-phase panels)\u003c\/li\u003e\n\u003cli\u003eElectronic short and overload protection of alarms\u003c\/li\u003e\n\u003cli\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHydroSTART single or dual pump capacitive touch keypad interface:\n\u003cul\u003e\n\u003cli\u003eIndicator lights for system and pump status\u003c\/li\u003e\n\u003cli\u003eButtons for alarm mute\/reset and pump mode selection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eHydroSTART PCB control module with dipswitches for adjusting configuration\u003c\/li\u003e\n\u003cli\u003eVisual (strobe) and audible (buzzer) alarms\u003c\/li\u003e\n\u003cli\u003ePump current sensing providing adjustable overload \u0026amp; other protections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSingle phase (230Vac) power supply\u003c\/li\u003e\n\u003cli\u003eDigital input for thermostat and time clock\u003c\/li\u003e\n\u003cli\u003eHot water terminal set up, with volt free BMS outputs and system enable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOutputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e2x pump supply outputs\u003c\/li\u003e\n\u003cli\u003eBMS volt-free output for common fault\u003c\/li\u003e\n\u003cli\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/08f5a11902b64509503920491cac62bb60c5a92e.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/0fde2ce949a2d88c6cf6a1fee529c31b7451011f.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation Manual\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/2bd7c38a494e8c01cbfb4d1f1189308a61b1a103.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuick Start Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/85a2dcb6f7983bd6b95a1a57c28f6e6839cb322b.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"0.1-6amp","offer_id":45615470051437,"sku":"FPC-82241-HWC-1","price":1716.0,"currency_code":"AUD","in_stock":true},{"title":"5-16 amp","offer_id":45615470084205,"sku":"FPC-82241-HWC-2","price":1716.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPC-82241-ID-product.webp?v=1785468967"},{"product_id":"hydrostart-hwc-1ph-2-pump-0-1-16a-c-w-id-time-clock-fpc-82241","title":"HydroSTART - HWC 1PH 2 Pump 0.1-16A c\/w ID \u0026Time Clock - FPC-82241-HWC\/TC","description":"\u003cp\u003eMATelec Australia's HydroSTART Controller brings the features of the standard single and dual pump controllers into a new age with a redesigned capacitive touch keypad and control module with pump current sensing, providing wide range electronic overload protection which now functions with both single and three phase pumps.\u003c\/p\u003e\n\u003cp\u003eAdditional control inputs and functionality have been incorporated into the new design to enhance the controller's flexibility and cover an even wider range of pumping applications. The HydroSTART is the new standard for pump controls.\u003c\/p\u003e\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003ch4\u003eEnclosure\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eEnclosure size: 400x400x200mm\u003c\/li\u003e\n\u003cli\u003ePowder coated mild steel enclosure with removable gland plate\u003c\/li\u003e\n\u003cli\u003eIP56 rated with inner door for outdoor mounting (inner door version)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProtection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSelectable overload range: 0.1-6 Amp, 5-16 Amp\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003ePad-lockable mains power isolator switch\u003c\/li\u003e\n\u003cli\u003eLow voltage control and input circuitry\u003c\/li\u003e\n\u003cli\u003eIndividual pump circuit breaker protection\/isolation\u003c\/li\u003e\n\u003cli\u003eContactors for pump switching (three-phase panels)\u003c\/li\u003e\n\u003cli\u003eElectronic short and overload protection of alarms\u003c\/li\u003e\n\u003cli\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHydroSTART single or dual pump capacitive touch keypad interface:\n\u003cul\u003e\n\u003cli\u003eIndicator lights for system and pump status\u003c\/li\u003e\n\u003cli\u003eButtons for alarm mute\/reset and pump mode selection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eHydroSTART PCB control module with dipswitches for adjusting configuration\u003c\/li\u003e\n\u003cli\u003eVisual (strobe) and audible (buzzer) alarms\u003c\/li\u003e\n\u003cli\u003ePump current sensing providing adjustable overload \u0026amp; other protections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSingle phase (230Vac) power supply\u003c\/li\u003e\n\u003cli\u003eDigital input for thermostat and time clock\u003c\/li\u003e\n\u003cli\u003eHot water terminal set up, with volt free BMS outputs and system enable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOutputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e2x pump supply outputs\u003c\/li\u003e\n\u003cli\u003eBMS volt-free output for common fault\u003c\/li\u003e\n\u003cli\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/08f5a11902b64509503920491cac62bb60c5a92e.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/0fde2ce949a2d88c6cf6a1fee529c31b7451011f.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation Manual\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/2bd7c38a494e8c01cbfb4d1f1189308a61b1a103.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuick Start Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/85a2dcb6f7983bd6b95a1a57c28f6e6839cb322b.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"0.1-6amp","offer_id":45615467167853,"sku":"FPC-82241-HWC\/TC-1","price":1803.12,"currency_code":"AUD","in_stock":true},{"title":"5-16 amp","offer_id":45615467200621,"sku":"FPC-82241-HWC\/TC-2","price":1803.12,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPC-82241-TC-product.webp?v=1785469180"},{"product_id":"hydrostart-hwc-1ph-2-pump-0-1-16a-c-w-id-tc-bms-fpc-82241","title":"HydroSTART - HWC 1PH 2 Pump 0.1-16A c\/w ID, TC \u0026 BMS - FPC-82241-HWC\/TC\/BMS","description":"\u003cp\u003eMATelec Australia's HydroSTART Controller brings the features of the standard single and dual pump controllers into a new age with a redesigned capacitive touch keypad and control module with pump current sensing, providing wide range electronic overload protection which now functions with both single and three phase pumps.\u003c\/p\u003e\n\u003cp\u003eAdditional control inputs and functionality have been incorporated into the new design to enhance the controller's flexibility and cover an even wider range of pumping applications. The HydroSTART is the new standard for pump controls.\u003c\/p\u003e\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003ch4\u003eEnclosure\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eEnclosure size: 400x400x200mm\u003c\/li\u003e\n\u003cli\u003ePowder coated mild steel enclosure with removable gland plate\u003c\/li\u003e\n\u003cli\u003eIP56 rated with inner door for outdoor mounting (inner door version)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProtection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSelectable overload range: 0.1-6 Amp, 5-16 Amp\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003ePad-lockable mains power isolator switch\u003c\/li\u003e\n\u003cli\u003eLow voltage control and input circuitry\u003c\/li\u003e\n\u003cli\u003eIndividual pump circuit breaker protection\/isolation\u003c\/li\u003e\n\u003cli\u003eContactors for pump switching (three-phase panels)\u003c\/li\u003e\n\u003cli\u003eElectronic short and overload protection of alarms\u003c\/li\u003e\n\u003cli\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHydroSTART single or dual pump capacitive touch keypad interface:\n\u003cul\u003e\n\u003cli\u003eIndicator lights for system and pump status\u003c\/li\u003e\n\u003cli\u003eButtons for alarm mute\/reset and pump mode selection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eHydroSTART PCB control module with dipswitches for adjusting configuration\u003c\/li\u003e\n\u003cli\u003eVisual (strobe) and audible (buzzer) alarms\u003c\/li\u003e\n\u003cli\u003ePump current sensing providing adjustable overload \u0026amp; other protections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSingle phase (230Vac) power supply\u003c\/li\u003e\n\u003cli\u003eDigital input for thermostat and time clock\u003c\/li\u003e\n\u003cli\u003eHot water terminal set up, with volt free BMS outputs and system enable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOutputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e2x pump supply outputs\u003c\/li\u003e\n\u003cli\u003eBMS volt-free output for common fault\u003c\/li\u003e\n\u003cli\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/08f5a11902b64509503920491cac62bb60c5a92e.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/0fde2ce949a2d88c6cf6a1fee529c31b7451011f.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation Manual\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/2bd7c38a494e8c01cbfb4d1f1189308a61b1a103.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuick Start Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/85a2dcb6f7983bd6b95a1a57c28f6e6839cb322b.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"0.1-6amp","offer_id":45615465758829,"sku":"FPC-82241-HWC\/TC\/BMS-1","price":2351.36,"currency_code":"AUD","in_stock":true},{"title":"5-16 amp","offer_id":45615465791597,"sku":"FPC-82241-HWC\/TC\/BMS-2","price":2351.36,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPC-82241-TC-BMS-product.webp?v=1785471551"},{"product_id":"hydrostart-hwc-3ph-2-pump-0-1-16a-c-w-id-fpc-82243","title":"HydroSTART - HWC 3PH 2 Pump 0.1-16A c\/w ID - FPC-82243-HWC","description":"\u003cp\u003eMATelec Australia's HydroSTART Controller brings the features of the standard single and dual pump controllers into a new age with a redesigned capacitive touch keypad and control module with pump current sensing, providing wide range electronic overload protection which now functions with both single and three phase pumps.\u003c\/p\u003e\n\u003cp\u003eAdditional control inputs and functionality have been incorporated into the new design to enhance the controller's flexibility and cover an even wider range of pumping applications. The HydroSTART is the new standard for pump controls.\u003c\/p\u003e\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003ch4\u003eEnclosure\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eEnclosure size: 400x400x200mm\u003c\/li\u003e\n\u003cli\u003ePowder coated mild steel enclosure with removable gland plate\u003c\/li\u003e\n\u003cli\u003eIP56 rated with inner door for outdoor mounting (inner door version)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProtection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSelectable overload range: 0.1-6 Amp, 5-16 Amp\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003ePad-lockable mains power isolator switch\u003c\/li\u003e\n\u003cli\u003eLow voltage control and input circuitry\u003c\/li\u003e\n\u003cli\u003eIndividual pump circuit breaker protection\/isolation\u003c\/li\u003e\n\u003cli\u003eContactors for pump switching (three-phase panels)\u003c\/li\u003e\n\u003cli\u003eElectronic short and overload protection of alarms\u003c\/li\u003e\n\u003cli\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHydroSTART single or dual pump capacitive touch keypad interface:\n\u003cul\u003e\n\u003cli\u003eIndicator lights for system and pump status\u003c\/li\u003e\n\u003cli\u003eButtons for alarm mute\/reset and pump mode selection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eHydroSTART PCB control module with dipswitches for adjusting configuration\u003c\/li\u003e\n\u003cli\u003eVisual (strobe) and audible (buzzer) alarms\u003c\/li\u003e\n\u003cli\u003ePump current sensing providing adjustable overload \u0026amp; other protections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThree phase (400Vac) power supply \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eDigital input for thermostat and time clock\u003c\/li\u003e\n\u003cli\u003eHot water terminal set up, with volt free BMS outputs and system enable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOutputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e2x pump supply outputs\u003c\/li\u003e\n\u003cli\u003eBMS volt-free output for common fault\u003c\/li\u003e\n\u003cli\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/08f5a11902b64509503920491cac62bb60c5a92e.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/0fde2ce949a2d88c6cf6a1fee529c31b7451011f.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation Manual\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/2bd7c38a494e8c01cbfb4d1f1189308a61b1a103.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuick Start Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/85a2dcb6f7983bd6b95a1a57c28f6e6839cb322b.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"0.1-6amp","offer_id":45615492661357,"sku":"FPC-82243-HWC-1","price":1807.52,"currency_code":"AUD","in_stock":true},{"title":"5-16 amp","offer_id":45615492694125,"sku":"FPC-82243-HWC-2","price":1807.52,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPC-82243-ID-product.webp?v=1785473370"},{"product_id":"hydrostart-hwc-3ph-2-pump-0-1-16a-c-w-id-tc-fpc-82243","title":"HydroSTART - HWC 3PH 2 Pump 0.1-16A c\/w ID \u0026 TC - FPC-82243-HWC\/TC","description":"\u003cp\u003eMATelec Australia's HydroSTART Controller brings the features of the standard single and dual pump controllers into a new age with a redesigned capacitive touch keypad and control module with pump current sensing, providing wide range electronic overload protection which now functions with both single and three phase pumps.\u003c\/p\u003e\n\u003cp\u003eAdditional control inputs and functionality have been incorporated into the new design to enhance the controller's flexibility and cover an even wider range of pumping applications. The HydroSTART is the new standard for pump controls.\u003c\/p\u003e\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003ch4\u003eEnclosure\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eEnclosure size: 400x400x200mm\u003c\/li\u003e\n\u003cli\u003ePowder coated mild steel enclosure with removable gland plate\u003c\/li\u003e\n\u003cli\u003eIP56 rated with inner door for outdoor mounting (inner door version)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProtection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSelectable overload range: 0.1-6 Amp, 5-16 Amp\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003ePad-lockable mains power isolator switch\u003c\/li\u003e\n\u003cli\u003eLow voltage control and input circuitry\u003c\/li\u003e\n\u003cli\u003eIndividual pump circuit breaker protection\/isolation\u003c\/li\u003e\n\u003cli\u003eContactors for pump switching (three-phase panels)\u003c\/li\u003e\n\u003cli\u003eElectronic short and overload protection of alarms\u003c\/li\u003e\n\u003cli\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHydroSTART single or dual pump capacitive touch keypad interface:\n\u003cul\u003e\n\u003cli\u003eIndicator lights for system and pump status\u003c\/li\u003e\n\u003cli\u003eButtons for alarm mute\/reset and pump mode selection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eHydroSTART PCB control module with dipswitches for adjusting configuration\u003c\/li\u003e\n\u003cli\u003eVisual (strobe) and audible (buzzer) alarms\u003c\/li\u003e\n\u003cli\u003ePump current sensing providing adjustable overload \u0026amp; other protections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThree phase (400Vac) power supply \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eDigital input for thermostat and time clock\u003c\/li\u003e\n\u003cli\u003eHot water terminal set up, with volt free BMS outputs and system enable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOutputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e2x pump supply outputs\u003c\/li\u003e\n\u003cli\u003eBMS volt-free output for common fault\u003c\/li\u003e\n\u003cli\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/08f5a11902b64509503920491cac62bb60c5a92e.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/0fde2ce949a2d88c6cf6a1fee529c31b7451011f.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation Manual\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/2bd7c38a494e8c01cbfb4d1f1189308a61b1a103.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuick Start Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/85a2dcb6f7983bd6b95a1a57c28f6e6839cb322b.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"0.1-6amp","offer_id":45615456551021,"sku":"FPC-82243-HWC\/TC-2","price":2759.68,"currency_code":"AUD","in_stock":true},{"title":"5-16 amp","offer_id":45615456583789,"sku":"FPC-82243-HWC\/TC-1","price":2759.68,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPC-82243-ID-TC-product.webp?v=1785473553"},{"product_id":"hydrostart-hwc-3ph-2-pump-0-1-16a-c-w-id-tc-bms-fpc-82243","title":"HydroSTART - HWC 3PH 2 Pump 0.1-16A c\/w ID, TC \u0026 BMS - FPC-82243-HWC\/TC\/BMS","description":"\u003cp\u003eMATelec Australia's HydroSTART Controller brings the features of the standard single and dual pump controllers into a new age with a redesigned capacitive touch keypad and control module with pump current sensing, providing wide range electronic overload protection which now functions with both single and three phase pumps.\u003c\/p\u003e\n\u003cp\u003eAdditional control inputs and functionality have been incorporated into the new design to enhance the controller's flexibility and cover an even wider range of pumping applications. The HydroSTART is the new standard for pump controls.\u003c\/p\u003e\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003ch4\u003eEnclosure\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eEnclosure size: 400x400x200mm\u003c\/li\u003e\n\u003cli\u003ePowder coated mild steel enclosure with removable gland plate\u003c\/li\u003e\n\u003cli\u003eIP56 rated with inner door for outdoor mounting (inner door version)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProtection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSelectable overload range: 0.1-6 Amp, 5-16 Amp\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003ePad-lockable mains power isolator switch\u003c\/li\u003e\n\u003cli\u003eLow voltage control and input circuitry\u003c\/li\u003e\n\u003cli\u003eIndividual pump circuit breaker protection\/isolation\u003c\/li\u003e\n\u003cli\u003eContactors for pump switching (three-phase panels)\u003c\/li\u003e\n\u003cli\u003eElectronic short and overload protection of alarms\u003c\/li\u003e\n\u003cli\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHydroSTART single or dual pump capacitive touch keypad interface:\n\u003cul\u003e\n\u003cli\u003eIndicator lights for system and pump status\u003c\/li\u003e\n\u003cli\u003eButtons for alarm mute\/reset and pump mode selection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eHydroSTART PCB control module with dipswitches for adjusting configuration\u003c\/li\u003e\n\u003cli\u003eVisual (strobe) and audible (buzzer) alarms\u003c\/li\u003e\n\u003cli\u003ePump current sensing providing adjustable overload \u0026amp; other protections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThree phase (400Vac) power supply \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eDigital input for thermostat and time clock\u003c\/li\u003e\n\u003cli\u003eHot water terminal set up, with volt free BMS outputs and system enable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOutputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e2x pump supply outputs\u003c\/li\u003e\n\u003cli\u003eBMS volt-free output for common fault\u003c\/li\u003e\n\u003cli\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/08f5a11902b64509503920491cac62bb60c5a92e.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/0fde2ce949a2d88c6cf6a1fee529c31b7451011f.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation Manual\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/2bd7c38a494e8c01cbfb4d1f1189308a61b1a103.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuick Start Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/85a2dcb6f7983bd6b95a1a57c28f6e6839cb322b.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"0.1-6amp","offer_id":45615456452717,"sku":"FPC-82243-HWC\/TC\/BMS-1","price":3057.12,"currency_code":"AUD","in_stock":true},{"title":"5-16 amp","offer_id":45615456485485,"sku":"FPC-82243-HWC\/TC\/BMS-2","price":3057.12,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPC-82243-ID-TC-BMS-Product.webp?v=1785473787"},{"product_id":"hydrowhiz-submersible-level-controller-3ph-2-pump-soft-starter-fpc-63243-s4-0-s90","title":"HydroWHIZ Submersible Level Controller (3PH 2 Pump Soft Starter) - FPC-63243-(S4.0-S22)","description":"\u003cp\u003eMATelec Australia's HydroWHIZ Submersible Level Controller is a premium multi-pump controller designed for advanced control of submersible pumping systems. Featuring a colour touchscreen HMI, HydroWHIZ PCB control module and flexible level, pressure and temperature control modes, it provides comprehensive pump control, monitoring and protection. This three-phase, two-pump version supports advanced functions including pump staging and destaging, duty sharing and alternation, staggered pump start and stop, pump limiting, data logging, trend graphs and diagnostic functions. The soft starter version is available with soft starter ratings from 4.0 kW to 90 kW.\u003c\/p\u003e\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003ch4\u003eEnclosure\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIP56 rated, powder-coated mild steel enclosure with inner door and removable gland plate\u003c\/li\u003e\n\u003cli\u003eEnclosure size: 400x400x250mm\u003c\/li\u003e\n\u003cli\u003eEnclosure size will increase for soft starter ratings and optional additions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProtection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003ePad-lockable mains power isolator switch\u003c\/li\u003e\n\u003cli\u003eCircuit breaker protected low voltage control and input circuitry\u003c\/li\u003e\n\u003cli\u003eIndividual pump isolation\u003c\/li\u003e\n\u003cli\u003eContactor protection of pump motors\u003c\/li\u003e\n\u003cli\u003eDin rail-mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHydroWHIZ colour touch screen HMI\u003c\/li\u003e\n\u003cli\u003eHydroWHIZ PCB control module\u003c\/li\u003e\n\u003cli\u003eVisual strobe and mutable audible buzzer alarms\u003c\/li\u003e\n\u003cli\u003eMain screen with system status and auto\/off\/manual modes\u003c\/li\u003e\n\u003cli\u003ePump screens with status, logged data and auto\/off\/manual control\u003c\/li\u003e\n\u003cli\u003eAlarm screens with mute\/reset and date and time-stamped historical faults\u003c\/li\u003e\n\u003cli\u003eLogged data including system event and fault counts, pump starts and run hours\u003c\/li\u003e\n\u003cli\u003eAnalogue feedback value trend graph\u003c\/li\u003e\n\u003cli\u003eSystem diagnostics and factory reset\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThree phase (400Vac) power supply\u003c\/li\u003e\n\u003cli\u003eAnalogue 4-20mA input for level, pressure or temperature transducer\u003c\/li\u003e\n\u003cli\u003eUp to 8x digital 24Vdc inputs for low, stop, start, standby start and high float switches, pressure switches or thermostats\u003c\/li\u003e\n\u003cli\u003eSystem enable\/disable input\u003c\/li\u003e\n\u003cli\u003eLow flow switch input\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eThermal switch inputs per pump\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOutputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e2 pump outputs\u003c\/li\u003e\n\u003cli\u003eBMS volt-free output for common fault\u003c\/li\u003e\n\u003cli\u003eAnalogue 0-10V output mirroring the analogue input\u003c\/li\u003e\n\u003cli\u003eOutput for solenoid valve available on request\u003c\/li\u003e\n\u003cli\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSoft Starter\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSoft starter control\u003c\/li\u003e\n\u003cli\u003eSoft starter rating: 4.0 kW to 90 kW\u003c\/li\u003e\n\u003cli\u003eSoft starter rating above 22 kw to 90kw prices will be available upon request.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFunction Features\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eControl of up to 6 pumps in duty, duty assist and standby configurations\u003c\/li\u003e\n\u003cli\u003ePump limiting for maximum flow or power requirements\u003c\/li\u003e\n\u003cli\u003eAdjustable duty sharing and alternation\u003c\/li\u003e\n\u003cli\u003ePump staging and destaging\u003c\/li\u003e\n\u003cli\u003eStaggered pump start and stop\u003c\/li\u003e\n\u003cli\u003eManual system and pump control with 10-minute timeout\u003c\/li\u003e\n\u003cli\u003eLevel, pressure or temperature control\u003c\/li\u003e\n\u003cli\u003eTank emptying or filling control\u003c\/li\u003e\n\u003cli\u003e4-20mA hydrostatic level transducer and float switch level control\u003c\/li\u003e\n\u003cli\u003eTank top-up valve control\u003c\/li\u003e\n\u003cli\u003eMaintain minimum level function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFault Protection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHigh and low level, pressure or temperature protection\u003c\/li\u003e\n\u003cli\u003eAuxiliary tank level protection\u003c\/li\u003e\n\u003cli\u003ePump anti-seize protection\u003c\/li\u003e\n\u003cli\u003eMaximum run protection\u003c\/li\u003e\n\u003cli\u003ePump cycle protection\u003c\/li\u003e\n\u003cli\u003eNo flow protection\u003c\/li\u003e\n\u003cli\u003eFeedback signal fault protection\u003c\/li\u003e\n\u003cli\u003ePump overload protection\u003c\/li\u003e\n\u003cli\u003ePump thermal switch protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommon Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWater Transfer\u003c\/li\u003e\n\u003cli\u003eTank Fill\u003c\/li\u003e\n\u003cli\u003eSewage Pump Out\u003c\/li\u003e\n\u003cli\u003eStormwater Pump Out\u003c\/li\u003e\n\u003cli\u003ePressure Boosting\u003c\/li\u003e\n\u003cli\u003eHot Water Recirculation\u003c\/li\u003e\n\u003cli\u003eChiller Supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"pdf-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/e54d9eba0e4ab3257a8d93c1c52aaa5a00c4f088.pdf\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"-S4.0 \/ 4.0 kW","offer_id":45597622304877,"sku":"FPC-63243-S4","price":7311.04,"currency_code":"AUD","in_stock":true},{"title":"-S5.5 \/ 5.5 kW","offer_id":45597622337645,"sku":"FPC-63243-S5.5","price":7866.32,"currency_code":"AUD","in_stock":true},{"title":"-S7.5 \/ 7.5 kW","offer_id":45597622370413,"sku":"FPC-63243-S7.5","price":7974.56,"currency_code":"AUD","in_stock":true},{"title":"-S11 \/ 11 kW","offer_id":45597622403181,"sku":"FPC-63243-S11","price":8528.08,"currency_code":"AUD","in_stock":true},{"title":"-S15 \/ 15 kW","offer_id":45597622435949,"sku":"FPC-63243-S15","price":8965.44,"currency_code":"AUD","in_stock":true},{"title":"-S22 \/ 22 kW","offer_id":45597622468717,"sku":"FPC-63243-S22","price":10028.48,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPC-63343-product.webp?v=1785397859"},{"product_id":"hydrowhiz-submersible-level-controller-3ph-3-pump-soft-starter-fpc-63343-s4-0-s90","title":"HydroWHIZ Submersible Level Controller (3PH 3 Pump Soft Starter) - FPC-63343-(S4.0-S22)","description":"\u003cp\u003eMATelec Australia's HydroWHIZ Submersible Level Controller is a premium multi-pump controller designed for advanced control of submersible pumping systems. Featuring a colour touchscreen HMI, HydroWHIZ PCB control module and flexible level, pressure and temperature control modes, it provides comprehensive pump control, monitoring and protection. This three-phase, three-pump version supports advanced functions including pump staging and destaging, duty sharing and alternation, staggered pump start and stop, pump limiting, data logging, trend graphs and diagnostic functions. The soft starter version is available with soft starter ratings from 4.0 kW to 90 kW.\u003c\/p\u003e\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003ch4\u003eEnclosure\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIP56 rated, powder-coated mild steel enclosure with inner door and removable gland plate\u003c\/li\u003e\n\u003cli\u003eEnclosure size: 400x400x250mm\u003c\/li\u003e\n\u003cli\u003eEnclosure size will increase for soft starter ratings and optional additions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProtection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003ePad-lockable mains power isolator switch\u003c\/li\u003e\n\u003cli\u003eCircuit breaker protected low voltage control and input circuitry\u003c\/li\u003e\n\u003cli\u003eIndividual pump isolation\u003c\/li\u003e\n\u003cli\u003eContactor protection of pump motors\u003c\/li\u003e\n\u003cli\u003eDin rail-mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHydroWHIZ colour touch screen HMI\u003c\/li\u003e\n\u003cli\u003eHydroWHIZ PCB control module\u003c\/li\u003e\n\u003cli\u003eVisual strobe and mutable audible buzzer alarms\u003c\/li\u003e\n\u003cli\u003eMain screen with system status and auto\/off\/manual modes\u003c\/li\u003e\n\u003cli\u003ePump screens with status, logged data and auto\/off\/manual control\u003c\/li\u003e\n\u003cli\u003eAlarm screens with mute\/reset and date and time-stamped historical faults\u003c\/li\u003e\n\u003cli\u003eLogged data including system event and fault counts, pump starts and run hours\u003c\/li\u003e\n\u003cli\u003eAnalogue feedback value trend graph\u003c\/li\u003e\n\u003cli\u003eSystem diagnostics and factory reset\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThree phase (400Vac) power supply\u003c\/li\u003e\n\u003cli\u003eAnalogue 4-20mA input for level, pressure or temperature transducer\u003c\/li\u003e\n\u003cli\u003eUp to 8x digital 24Vdc inputs for low, stop, start, standby start and high float switches, pressure switches or thermostats\u003c\/li\u003e\n\u003cli\u003eSystem enable\/disable input\u003c\/li\u003e\n\u003cli\u003eLow flow switch input\u003c\/li\u003e\n\u003cli\u003eThermal switch inputs per pump\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOutputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e3 pump outputs\u003c\/li\u003e\n\u003cli\u003eBMS volt-free output for common fault\u003c\/li\u003e\n\u003cli\u003eAnalogue 0-10V output mirroring the analogue input\u003c\/li\u003e\n\u003cli\u003eOutput for solenoid valve available on request\u003c\/li\u003e\n\u003cli\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSoft Starter\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSoft starter control\u003c\/li\u003e\n\u003cli\u003eSoft starter rating: 4.0 kW to 90 kW\u003c\/li\u003e\n\u003cli\u003eSoft starter rating above 22 kw to 90kw prices will be available upon request.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFunction Features\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eControl of up to 6 pumps in duty, duty assist and standby configurations\u003c\/li\u003e\n\u003cli\u003ePump limiting for maximum flow or power requirements\u003c\/li\u003e\n\u003cli\u003eAdjustable duty sharing and alternation\u003c\/li\u003e\n\u003cli\u003ePump staging and destaging\u003c\/li\u003e\n\u003cli\u003eStaggered pump start and stop\u003c\/li\u003e\n\u003cli\u003eManual system and pump control with 10-minute timeout\u003c\/li\u003e\n\u003cli\u003eLevel, pressure or temperature control\u003c\/li\u003e\n\u003cli\u003eTank emptying or filling control\u003c\/li\u003e\n\u003cli\u003e4-20mA hydrostatic level transducer and float switch level control\u003c\/li\u003e\n\u003cli\u003eTank top-up valve control\u003c\/li\u003e\n\u003cli\u003eMaintain minimum level function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFault Protection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHigh and low level, pressure or temperature protection\u003c\/li\u003e\n\u003cli\u003eAuxiliary tank level protection\u003c\/li\u003e\n\u003cli\u003ePump anti-seize protection\u003c\/li\u003e\n\u003cli\u003eMaximum run protection\u003c\/li\u003e\n\u003cli\u003ePump cycle protection\u003c\/li\u003e\n\u003cli\u003eNo flow protection\u003c\/li\u003e\n\u003cli\u003eFeedback signal fault protection\u003c\/li\u003e\n\u003cli\u003ePump overload protection\u003c\/li\u003e\n\u003cli\u003ePump thermal switch protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommon Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWater Transfer\u003c\/li\u003e\n\u003cli\u003eTank Fill\u003c\/li\u003e\n\u003cli\u003eSewage Pump Out\u003c\/li\u003e\n\u003cli\u003eStormwater Pump Out\u003c\/li\u003e\n\u003cli\u003ePressure Boosting\u003c\/li\u003e\n\u003cli\u003eHot Water Recirculation\u003c\/li\u003e\n\u003cli\u003eChiller Supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"pdf-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/e54d9eba0e4ab3257a8d93c1c52aaa5a00c4f088.pdf\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"-S4.0 \/ 4.0 kW","offer_id":45597630791789,"sku":"FPC-63343-S4","price":9850.72,"currency_code":"AUD","in_stock":true},{"title":"-S5.5 \/ 5.5 kW","offer_id":45597630824557,"sku":"FPC-63343-S5.5","price":10380.48,"currency_code":"AUD","in_stock":true},{"title":"-S7.5 \/ 7.5 kW","offer_id":45597630857325,"sku":"FPC-63343-S7.5","price":10936.64,"currency_code":"AUD","in_stock":true},{"title":"-S11 \/ 11 kW","offer_id":45597630890093,"sku":"FPC-63343-S11","price":12046.32,"currency_code":"AUD","in_stock":true},{"title":"-S15 \/ 15 kW","offer_id":45597630922861,"sku":"FPC-63343-S15","price":12874.4,"currency_code":"AUD","in_stock":true},{"title":"-S22 \/ 22 kW","offer_id":45597630955629,"sku":"FPC-63343-S22","price":16356.56,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPC-63343-product.webp?v=1785397859"},{"product_id":"hydrostart-hot-water-circulation-controller-3ph-1-pump-soft-starter-fpc-82143-s4-0-s90","title":"HydroSTART Submersible Level Controller (3PH 1 Pump Soft Starter) - FPC-82143-(S4.0-S90)","description":"\u003cp\u003eMATelec Australia's HydroSTART Controller brings the features of the standard single and dual pump controllers into a new age with a redesigned capacitive touch keypad and control module with pump current sensing, providing flexible pump control for both single and three phase pumps.\u003c\/p\u003e\n\u003cp\u003eAdditional control inputs and functionality have been incorporated into the new design to enhance the controller's flexibility and cover an even wider range of pumping applications. The HydroSTART is the new standard for pump controls.\u003c\/p\u003e\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003ch4\u003eEnclosure\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eEnclosure size: 400x400x200mm\u003c\/li\u003e\n\u003cli\u003eEnclosure size will increase for soft starter ratings and optional additions.\u003c\/li\u003e\n\u003cli\u003ePowder coated mild steel enclosure with removable gland plate\u003c\/li\u003e\n\u003cli\u003eIP56 rated with inner door for outdoor mounting (inner door version)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProtection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003ePad-lockable mains power isolator switch\u003c\/li\u003e\n\u003cli\u003eLow voltage control and input circuitry\u003c\/li\u003e\n\u003cli\u003eIndividual pump circuit breaker protection\/isolation\u003c\/li\u003e\n\u003cli\u003eContactors for pump switching (three-phase panels)\u003c\/li\u003e\n\u003cli\u003eElectronic short and overload protection of alarms\u003c\/li\u003e\n\u003cli\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHydroSTART single or dual pump capacitive touch keypad interface:\n\u003cul\u003e\n\u003cli\u003eIndicator lights for system and pump status\u003c\/li\u003e\n\u003cli\u003eButtons for alarm mute\/reset and pump mode selection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eHydroSTART PCB control module with dipswitches for adjusting configuration\u003c\/li\u003e\n\u003cli\u003eVisual (strobe) and audible (buzzer) alarms\u003c\/li\u003e\n\u003cli\u003eSoft starter per pump with adjustable soft start and soft stop\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThree phase (400Vac) power supply\u003c\/li\u003e\n\u003cli\u003eDigital input for thermostat and time clock\u003c\/li\u003e\n\u003cli\u003eHot water terminal set up, with volt free BMS outputs and system enable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOutputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e1x pump supply output\u003c\/li\u003e\n\u003cli\u003eBMS volt-free output for common fault\u003c\/li\u003e\n\u003cli\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSoft Starter Options\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSoft starter control\u003c\/li\u003e\n\u003cli\u003eSoft starter rating: 4.0 kW to 90 kW\u003c\/li\u003e\n\u003cli\u003eSoft starter rating above 55 kw to 90kw prices will be available upon request.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/08f5a11902b64509503920491cac62bb60c5a92e.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/0fde2ce949a2d88c6cf6a1fee529c31b7451011f.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation Manual\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/2bd7c38a494e8c01cbfb4d1f1189308a61b1a103.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuick Start Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/85a2dcb6f7983bd6b95a1a57c28f6e6839cb322b.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"-S4.0 \/ 4.0 kW","offer_id":45599013208173,"sku":"FPC-82143-S4","price":11234.96,"currency_code":"AUD","in_stock":true},{"title":"-S5.5 \/ 5.5 kW","offer_id":45599013240941,"sku":"FPC-82143-S5.5","price":4283.84,"currency_code":"AUD","in_stock":true},{"title":"-S7.5 \/ 7.5 kW","offer_id":45599013273709,"sku":"FPC-82143-S7.5","price":4402.64,"currency_code":"AUD","in_stock":true},{"title":"-S11 \/ 11 kW","offer_id":45599013306477,"sku":"FPC-82143-S11","price":5045.92,"currency_code":"AUD","in_stock":true},{"title":"-S15 \/ 15 kW","offer_id":45599013339245,"sku":"FPC-82143-S15","price":5323.12,"currency_code":"AUD","in_stock":true},{"title":"-S18.5 \/ 18.5 kW","offer_id":45626854113389,"sku":"FPC-82143-S18.5","price":5722.64,"currency_code":"AUD","in_stock":true},{"title":"-S22 \/ 22 kW","offer_id":45599013372013,"sku":"FPC-82143-S22","price":6369.44,"currency_code":"AUD","in_stock":true},{"title":"-S30 \/ 30 kW","offer_id":45599013404781,"sku":"FPC-82143-S30","price":9690.56,"currency_code":"AUD","in_stock":true},{"title":"-S37 \/ 37 kW","offer_id":45599013437549,"sku":"FPC-82143-S37","price":10829.28,"currency_code":"AUD","in_stock":true},{"title":"-S45 \/ 45 kW","offer_id":45599013470317,"sku":"FPC-82143-S45","price":11234.96,"currency_code":"AUD","in_stock":true},{"title":"-S55 \/ 55 kW","offer_id":45599013503085,"sku":"FPC-82143-S55","price":15475.68,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPC-82243-ID-product.webp?v=1785473370"},{"product_id":"hydrostart-hot-water-circulation-controller-3ph-2-pump-soft-starter-fpc-82243-s4-0-s90","title":"HydroSTART Submersible Level Controller (3PH 2 Pump Soft Starter) - FPC-82243-(S4.0-S90)","description":"\u003cp\u003eMATelec Australia's HydroSTART Controller brings the features of the standard single and dual pump controllers into a new age with a redesigned capacitive touch keypad and control module with pump current sensing, providing flexible pump control for both single and three phase pumps.\u003c\/p\u003e\n\u003cp\u003eAdditional control inputs and functionality have been incorporated into the new design to enhance the controller's flexibility and cover an even wider range of pumping applications. The HydroSTART is the new standard for pump controls.\u003c\/p\u003e\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003ch4\u003eEnclosure\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eEnclosure size: 400x400x200mm\u003c\/li\u003e\n\u003cli\u003eEnclosure size will increase for soft starter ratings and optional additions.\u003c\/li\u003e\n\u003cli\u003ePowder coated mild steel enclosure with removable gland plate\u003c\/li\u003e\n\u003cli\u003eIP56 rated with inner door for outdoor mounting (inner door version)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProtection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003ePad-lockable mains power isolator switch\u003c\/li\u003e\n\u003cli\u003eLow voltage control and input circuitry\u003c\/li\u003e\n\u003cli\u003eIndividual pump circuit breaker protection\/isolation\u003c\/li\u003e\n\u003cli\u003eContactors for pump switching (three-phase panels)\u003c\/li\u003e\n\u003cli\u003eElectronic short and overload protection of alarms\u003c\/li\u003e\n\u003cli\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHydroSTART single or dual pump capacitive touch keypad interface:\n\u003cul\u003e\n\u003cli\u003eIndicator lights for system and pump status\u003c\/li\u003e\n\u003cli\u003eButtons for alarm mute\/reset and pump mode selection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eHydroSTART PCB control module with dipswitches for adjusting configuration\u003c\/li\u003e\n\u003cli\u003eVisual (strobe) and audible (buzzer) alarms\u003c\/li\u003e\n\u003cli\u003eSoft starter per pump with adjustable soft start and soft stop\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThree phase (400Vac) power supply\u003c\/li\u003e\n\u003cli\u003eDigital input for thermostat and time clock\u003c\/li\u003e\n\u003cli\u003eHot water terminal set up, with volt free BMS outputs and system enable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOutputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e2x pump supply outputs\u003c\/li\u003e\n\u003cli\u003eBMS volt-free output for common fault\u003c\/li\u003e\n\u003cli\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSoft Starter Options\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSoft starter control\u003c\/li\u003e\n\u003cli\u003eSoft starter rating: 4.0 kW to 90 kW\u003c\/li\u003e\n\u003cli\u003eSoft starter rating above 37 kw to 90kw prices will be available upon request.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/08f5a11902b64509503920491cac62bb60c5a92e.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/0fde2ce949a2d88c6cf6a1fee529c31b7451011f.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation Manual\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/2bd7c38a494e8c01cbfb4d1f1189308a61b1a103.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuick Start Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/85a2dcb6f7983bd6b95a1a57c28f6e6839cb322b.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"-S4.0 \/ 4.0 kW","offer_id":45599015305325,"sku":"FPC-82243-S4","price":6122.16,"currency_code":"AUD","in_stock":true},{"title":"-S5.5 \/ 5.5 kW","offer_id":45599015338093,"sku":"FPC-82243-S5.5","price":6334.24,"currency_code":"AUD","in_stock":true},{"title":"-S7.5 \/ 7.5 kW","offer_id":45599015370861,"sku":"FPC-82243-S7.5","price":6599.12,"currency_code":"AUD","in_stock":true},{"title":"-S11 \/ 11 kW","offer_id":45599015403629,"sku":"FPC-82243-S11","price":7560.96,"currency_code":"AUD","in_stock":true},{"title":"-S15 \/ 15 kW","offer_id":45599015436397,"sku":"FPC-82243-S15","price":7976.32,"currency_code":"AUD","in_stock":true},{"title":"-S18.5 \/ 18.5 kW","offer_id":45626855882861,"sku":"FPC-82243-S18.5","price":8719.04,"currency_code":"AUD","in_stock":true},{"title":"-S22 \/ 22 kW","offer_id":45599015469165,"sku":"FPC-82243-S22","price":9541.84,"currency_code":"AUD","in_stock":true},{"title":"-S37 \/ 37 kW","offer_id":45599015534701,"sku":"FPC-82243-S37","price":19556.24,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPC-82243-ID-product.webp?v=1785473370"},{"product_id":"hydrostart-pro-submersible-pump-controller-1ph-2-pump-fpp-82241","title":"HydroSTART PRO Submersible Pump Controller (1PH 2 Pump) - FPP-82241","description":"\u003cp\u003eMATelec Australia’s HydroSTART PRO Controller is the flagship dual pump controller in the Australian Market. Designed for the professional, this controller features the highest quality enclosure, premium Schneider switchgear, intuitive capacitive touch keypad and Matelec Australia’s Market Leading HydroSTART Pro Control module.\u003c\/p\u003e\n\u003cp\u003eThe unit comes complete with pump current sensing and a wide range of electronic overload protection for both single and three phase pumps. A full suite of control inputs and functionality has been incorporated into the design to enhance the controller’s flexibility and cover an even wider range of pumping applications.\u003c\/p\u003e\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003ch4\u003eEnclosure\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eGrey powder coated galvanised mild steel IP66 with inner door\u003c\/li\u003e\n\u003cli\u003eEnclosure size: 400x400x200mm\u003c\/li\u003e\n\u003cli\u003eEnclosure size will increase for optional additions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProtection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eInner door mounted main isolator with door interlock\u003c\/li\u003e\n\u003cli\u003ePremium Schneider Circuit Breakers for individual pump protection\/isolation\u003c\/li\u003e\n\u003cli\u003eLow voltage control and input circuitry\u003c\/li\u003e\n\u003cli\u003ePremium Schneider Contactors for pump switching (three phase panels)\u003c\/li\u003e\n\u003cli\u003eElectronic short and overload protection of alarms\u003c\/li\u003e\n\u003cli\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHydroSTART dual pump capacitive touch keypad interface\u003c\/li\u003e\n\u003cli\u003eIndicator lights for system, pump and input status, level alarm\u003c\/li\u003e\n\u003cli\u003eButtons for alarm mute\/reset and pump mode selection\u003c\/li\u003e\n\u003cli\u003eHydroSTART PCB control module with dip-switches for adjusting configuration\u003c\/li\u003e\n\u003cli\u003eVisual (strobe) and audible (buzzer) alarms\u003c\/li\u003e\n\u003cli\u003ePump current sensing providing adjustable overload \u0026amp; other protections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSingle phase (230Vac) power supply\u003c\/li\u003e\n\u003cli\u003e6x digital inputs for float or pressure switches, optional prime loss flow switch and system enable\u003c\/li\u003e\n\u003cli\u003eStandard terminal setup: Low level, duty stop, duty start, standby start, high level and system enable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOutputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e2 pump supply outputs\u003c\/li\u003e\n\u003cli\u003eBMS volt free output for common fault\u003c\/li\u003e\n\u003cli\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFunctions\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eLevel control mode – Level empty operation controlled by up to 5 float switches\u003c\/li\u003e\n\u003cli\u003ePressure control mode – Pressure boost operation controlled by up to 3 pressure switches\u003c\/li\u003e\n\u003cli\u003eDuty sharing and alternation – Alternates on pump start and after set run times\u003c\/li\u003e\n\u003cli\u003eStaggered pump start – Prevents excessive current draw and reduces water surge\u003c\/li\u003e\n\u003cli\u003eManual pump control – Manual mode with optional timeout\u003c\/li\u003e\n\u003cli\u003eSystem enable input – Enables\/disables system in auto mode\u003c\/li\u003e\n\u003cli\u003eStatic duty mode – No duty alternation\u003c\/li\u003e\n\u003cli\u003eSmart chirp mode alarms – Audible alarm silences after 5 minutes, chirps every 5 minutes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFault Protection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHigh level alarm – Delayed alarm with auto\/manual reset depending on mode\u003c\/li\u003e\n\u003cli\u003eLow level protection – Shuts down pumps, manual reset only\u003c\/li\u003e\n\u003cli\u003eLow pressure protection – Shuts down pumps if input closed for 60 seconds\u003c\/li\u003e\n\u003cli\u003ePrime loss protection – Shuts down pumps if no flow for 30 seconds\u003c\/li\u003e\n\u003cli\u003ePump anti-seize protection – Runs pumps periodically during low use\u003c\/li\u003e\n\u003cli\u003ePump current sensing – Adjustable overload, undercurrent and zero current protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/49bb51d56250b36b65102dad6bfc116f753bea7e.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomation and Control Product Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/0fde2ce949a2d88c6cf6a1fee529c31b7451011f.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"Default Title","offer_id":45599596937325,"sku":"FPP-82241","price":3631.76,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPP-82241-PC-premium-polycarbonate-product.webp?v=1786437961"},{"product_id":"hydrostart-pro-submersible-pump-controller-1ph-2-pump-fpp-82241-pc","title":"HydroSTART PRO Submersible Pump Controller (1PH 2 Pump) - FPP-82241-PC","description":"\u003cp\u003eMATelec Australia’s HydroSTART PRO Controller is the flagship dual pump controller in the Australian Market. Designed for the professional, this controller features the highest quality enclosure, premium Schneider switchgear, intuitive capacitive touch keypad and Matelec Australia’s Market Leading HydroSTART Pro Control module.\u003c\/p\u003e\n\u003cp\u003eThe unit comes complete with pump current sensing and a wide range of electronic overload protection for both single and three phase pumps. A full suite of control inputs and functionality has been incorporated into the design to enhance the controller’s flexibility and cover an even wider range of pumping applications.\u003c\/p\u003e\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003ch4\u003eEnclosure\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003ePremium polycarbonate IP66 with inner door\u003c\/li\u003e\n\u003cli\u003eEnclosure size: 400x400x200mm\u003c\/li\u003e\n\u003cli\u003eEnclosure size will increase for optional additions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProtection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eInner door mounted main isolator with door interlock\u003c\/li\u003e\n\u003cli\u003ePremium Schneider Circuit Breakers for individual pump protection\/isolation\u003c\/li\u003e\n\u003cli\u003eLow voltage control and input circuitry\u003c\/li\u003e\n\u003cli\u003ePremium Schneider Contactors for pump switching (three phase panels)\u003c\/li\u003e\n\u003cli\u003eElectronic short and overload protection of alarms\u003c\/li\u003e\n\u003cli\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHydroSTART dual pump capacitive touch keypad interface\u003c\/li\u003e\n\u003cli\u003eIndicator lights for system, pump and input status, level alarm\u003c\/li\u003e\n\u003cli\u003eButtons for alarm mute\/reset and pump mode selection\u003c\/li\u003e\n\u003cli\u003eHydroSTART PCB control module with dip-switches for adjusting configuration\u003c\/li\u003e\n\u003cli\u003eVisual (strobe) and audible (buzzer) alarms\u003c\/li\u003e\n\u003cli\u003ePump current sensing providing adjustable overload \u0026amp; other protections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSingle phase (230Vac) power supply\u003c\/li\u003e\n\u003cli\u003e6x digital inputs for float or pressure switches, optional prime loss flow switch and system enable\u003c\/li\u003e\n\u003cli\u003eStandard terminal setup: Low level, duty stop, duty start, standby start, high level and system enable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOutputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e2 pump supply outputs\u003c\/li\u003e\n\u003cli\u003eBMS volt free output for common fault\u003c\/li\u003e\n\u003cli\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFunctions\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eLevel control mode – Level empty operation controlled by up to 5 float switches\u003c\/li\u003e\n\u003cli\u003ePressure control mode – Pressure boost operation controlled by up to 3 pressure switches\u003c\/li\u003e\n\u003cli\u003eDuty sharing and alternation – Alternates on pump start and after set run times\u003c\/li\u003e\n\u003cli\u003eStaggered pump start – Prevents excessive current draw and reduces water surge\u003c\/li\u003e\n\u003cli\u003eManual pump control – Manual mode with optional timeout\u003c\/li\u003e\n\u003cli\u003eSystem enable input – Enables\/disables system in auto mode\u003c\/li\u003e\n\u003cli\u003eStatic duty mode – No duty alternation\u003c\/li\u003e\n\u003cli\u003eSmart chirp mode alarms – Audible alarm silences after 5 minutes, chirps every 5 minutes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFault Protection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHigh level alarm – Delayed alarm with auto\/manual reset depending on mode\u003c\/li\u003e\n\u003cli\u003eLow level protection – Shuts down pumps, manual reset only\u003c\/li\u003e\n\u003cli\u003eLow pressure protection – Shuts down pumps if input closed for 60 seconds\u003c\/li\u003e\n\u003cli\u003ePrime loss protection – Shuts down pumps if no flow for 30 seconds\u003c\/li\u003e\n\u003cli\u003ePump anti-seize protection – Runs pumps periodically during low use\u003c\/li\u003e\n\u003cli\u003ePump current sensing – Adjustable overload, undercurrent and zero current protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/49bb51d56250b36b65102dad6bfc116f753bea7e.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomation and Control Product Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/0fde2ce949a2d88c6cf6a1fee529c31b7451011f.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"Default Title","offer_id":45599612076141,"sku":"FPP-82241-PC","price":4478.32,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPP-82241-PC-premium-polycarbonate-product.webp?v=1786437961"},{"product_id":"hydrostart-pro-submersible-pump-controller-1ph-2-pump-fpp-82241-ss","title":"HydroSTART PRO Submersible Pump Controller (1PH 2 Pump) - FPP-82241-SS","description":"\u003cp\u003eMATelec Australia’s HydroSTART PRO Controller is the flagship dual pump controller in the Australian Market. Designed for the professional, this controller features the highest quality enclosure, premium Schneider switchgear, intuitive capacitive touch keypad and Matelec Australia’s Market Leading HydroSTART Pro Control module.\u003c\/p\u003e\n\u003cp\u003eThe unit comes complete with pump current sensing and a wide range of electronic overload protection for both single and three phase pumps. A full suite of control inputs and functionality has been incorporated into the design to enhance the controller’s flexibility and cover an even wider range of pumping applications.\u003c\/p\u003e\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003ch4\u003eEnclosure Options\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003ePremium powder coated 316 stainless steel, IP66 with inner door\u003c\/li\u003e\n\u003cli\u003eEnclosure size: 400x400x200mm\u003c\/li\u003e\n\u003cli\u003eEnclosure size will increase for optional additions.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProtection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eInner door mounted main isolator with door interlock\u003c\/li\u003e\n\u003cli\u003ePremium Schneider Circuit Breakers for individual pump protection\/isolation\u003c\/li\u003e\n\u003cli\u003eLow voltage control and input circuitry\u003c\/li\u003e\n\u003cli\u003ePremium Schneider Contactors for pump switching (three phase panels)\u003c\/li\u003e\n\u003cli\u003eElectronic short and overload protection of alarms\u003c\/li\u003e\n\u003cli\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHydroSTART dual pump capacitive touch keypad interface\u003c\/li\u003e\n\u003cli\u003eIndicator lights for system, pump and input status, level alarm\u003c\/li\u003e\n\u003cli\u003eButtons for alarm mute\/reset and pump mode selection\u003c\/li\u003e\n\u003cli\u003eHydroSTART PCB control module with dip-switches for adjusting configuration\u003c\/li\u003e\n\u003cli\u003eVisual (strobe) and audible (buzzer) alarms\u003c\/li\u003e\n\u003cli\u003ePump current sensing providing adjustable overload \u0026amp; other protections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSingle phase (230Vac) power supply\u003c\/li\u003e\n\u003cli\u003e6x digital inputs for float or pressure switches, optional prime loss flow switch and system enable\u003c\/li\u003e\n\u003cli\u003eStandard terminal setup: Low level, duty stop, duty start, standby start, high level and system enable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOutputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e2 pump supply outputs\u003c\/li\u003e\n\u003cli\u003eBMS volt free output for common fault\u003c\/li\u003e\n\u003cli\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFunctions\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eLevel control mode – Level empty operation controlled by up to 5 float switches\u003c\/li\u003e\n\u003cli\u003ePressure control mode – Pressure boost operation controlled by up to 3 pressure switches\u003c\/li\u003e\n\u003cli\u003eDuty sharing and alternation – Alternates on pump start and after set run times\u003c\/li\u003e\n\u003cli\u003eStaggered pump start – Prevents excessive current draw and reduces water surge\u003c\/li\u003e\n\u003cli\u003eManual pump control – Manual mode with optional timeout\u003c\/li\u003e\n\u003cli\u003eSystem enable input – Enables\/disables system in auto mode\u003c\/li\u003e\n\u003cli\u003eStatic duty mode – No duty alternation\u003c\/li\u003e\n\u003cli\u003eSmart chirp mode alarms – Audible alarm silences after 5 minutes, chirps every 5 minutes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFault Protection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHigh level alarm – Delayed alarm with auto\/manual reset depending on mode\u003c\/li\u003e\n\u003cli\u003eLow level protection – Shuts down pumps, manual reset only\u003c\/li\u003e\n\u003cli\u003eLow pressure protection – Shuts down pumps if input closed for 60 seconds\u003c\/li\u003e\n\u003cli\u003ePrime loss protection – Shuts down pumps if no flow for 30 seconds\u003c\/li\u003e\n\u003cli\u003ePump anti-seize protection – Runs pumps periodically during low use\u003c\/li\u003e\n\u003cli\u003ePump current sensing – Adjustable overload, undercurrent and zero current protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/49bb51d56250b36b65102dad6bfc116f753bea7e.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomation and Control Product Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/0fde2ce949a2d88c6cf6a1fee529c31b7451011f.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"Default Title","offer_id":45599629639789,"sku":"FPP-82241-SS","price":3828.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPP-82241-SS-premium-polycarbonate-product.webp?v=1786438773"},{"product_id":"hydrostart-pro-submersible-pump-controller-1ph-2-pump-fpp-82241-x15","title":"HydroSTART PRO Submersible Pump Controller (1PH 2 Pump) - FPP-82241-X15","description":"\u003cp\u003eMATelec Australia’s HydroSTART PRO Controller is the flagship dual pump controller in the Australian Market. Designed for the professional, this controller features the highest quality enclosure, premium Schneider switchgear, intuitive capacitive touch keypad and Matelec Australia’s Market Leading HydroSTART Pro Control module.\u003c\/p\u003e\n\u003cp\u003eThe unit comes complete with pump current sensing and a wide range of electronic overload protection for both single and three phase pumps. A full suite of control inputs and functionality has been incorporated into the design to enhance the controller’s flexibility and cover an even wider range of pumping applications.\u003c\/p\u003e\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003ch4\u003eEnclosure Options\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eX15 orange powder coated galvanised mild steel, IP66 with inner door\u003c\/li\u003e\n\u003cli\u003eEnclosure size: 400x400x200mm\u003c\/li\u003e\n\u003cli\u003eEnclosure size will increase for optional additions.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProtection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eInner door mounted main isolator with door interlock\u003c\/li\u003e\n\u003cli\u003ePremium Schneider Circuit Breakers for individual pump protection\/isolation\u003c\/li\u003e\n\u003cli\u003eLow voltage control and input circuitry\u003c\/li\u003e\n\u003cli\u003ePremium Schneider Contactors for pump switching (three phase panels)\u003c\/li\u003e\n\u003cli\u003eElectronic short and overload protection of alarms\u003c\/li\u003e\n\u003cli\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHydroSTART dual pump capacitive touch keypad interface\u003c\/li\u003e\n\u003cli\u003eIndicator lights for system, pump and input status, level alarm\u003c\/li\u003e\n\u003cli\u003eButtons for alarm mute\/reset and pump mode selection\u003c\/li\u003e\n\u003cli\u003eHydroSTART PCB control module with dip-switches for adjusting configuration\u003c\/li\u003e\n\u003cli\u003eVisual (strobe) and audible (buzzer) alarms\u003c\/li\u003e\n\u003cli\u003ePump current sensing providing adjustable overload \u0026amp; other protections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSingle phase (230Vac) power supply\u003c\/li\u003e\n\u003cli\u003e6x digital inputs for float or pressure switches, optional prime loss flow switch and system enable\u003c\/li\u003e\n\u003cli\u003eStandard terminal setup: Low level, duty stop, duty start, standby start, high level and system enable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOutputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e2 pump supply outputs\u003c\/li\u003e\n\u003cli\u003eBMS volt free output for common fault\u003c\/li\u003e\n\u003cli\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFunctions\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eLevel control mode – Level empty operation controlled by up to 5 float switches\u003c\/li\u003e\n\u003cli\u003ePressure control mode – Pressure boost operation controlled by up to 3 pressure switches\u003c\/li\u003e\n\u003cli\u003eDuty sharing and alternation – Alternates on pump start and after set run times\u003c\/li\u003e\n\u003cli\u003eStaggered pump start – Prevents excessive current draw and reduces water surge\u003c\/li\u003e\n\u003cli\u003eManual pump control – Manual mode with optional timeout\u003c\/li\u003e\n\u003cli\u003eSystem enable input – Enables\/disables system in auto mode\u003c\/li\u003e\n\u003cli\u003eStatic duty mode – No duty alternation\u003c\/li\u003e\n\u003cli\u003eSmart chirp mode alarms – Audible alarm silences after 5 minutes, chirps every 5 minutes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFault Protection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHigh level alarm – Delayed alarm with auto\/manual reset depending on mode\u003c\/li\u003e\n\u003cli\u003eLow level protection – Shuts down pumps, manual reset only\u003c\/li\u003e\n\u003cli\u003eLow pressure protection – Shuts down pumps if input closed for 60 seconds\u003c\/li\u003e\n\u003cli\u003ePrime loss protection – Shuts down pumps if no flow for 30 seconds\u003c\/li\u003e\n\u003cli\u003ePump anti-seize protection – Runs pumps periodically during low use\u003c\/li\u003e\n\u003cli\u003ePump current sensing – Adjustable overload, undercurrent and zero current protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/49bb51d56250b36b65102dad6bfc116f753bea7e.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomation and Control Product Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/0fde2ce949a2d88c6cf6a1fee529c31b7451011f.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"Default Title","offer_id":45599637930093,"sku":"FPP-82241-X15","price":4123.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPP-82241-X15-product.webp?v=1786439061"},{"product_id":"hydrostart-pro-submersible-pump-controller-3ph-2-pump-fpp-82243","title":"HydroSTART PRO Submersible Pump Controller (3PH 2 Pump) - FPP-82243","description":"\u003cp bis_size='{\"x\":12,\"y\":9,\"w\":565,\"h\":78,\"abs_x\":618,\"abs_y\":270}'\u003eMATelec Australia’s HydroSTART PRO Controller is the flagship dual pump controller in the Australian Market. Designed for the professional, this controller features the highest quality enclosure, premium Schneider switchgear, intuitive capacitive touch keypad and Matelec Australia’s Market Leading HydroSTART Pro Control module.\u003c\/p\u003e\n\u003cp bis_size='{\"x\":12,\"y\":103,\"w\":565,\"h\":78,\"abs_x\":618,\"abs_y\":364}'\u003eThe unit comes complete with pump current sensing and a wide range of electronic overload protection for both single and three phase pumps. A full suite of control inputs and functionality has been incorporated into the design to enhance the controller’s flexibility and cover an even wider range of pumping applications.\u003c\/p\u003e\n\u003ch3 bis_size='{\"x\":12,\"y\":198,\"w\":565,\"h\":22,\"abs_x\":618,\"abs_y\":459}'\u003eProduct Details\u003c\/h3\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":231,\"w\":565,\"h\":19,\"abs_x\":618,\"abs_y\":492}'\u003eEnclosure Options\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":265,\"w\":565,\"h\":58,\"abs_x\":618,\"abs_y\":526}'\u003e\n\u003cli\u003eGrey powder coated galvanised mild steel IP66 with inner door\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":285,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":546}'\u003eEnclosure size: 400x400x200mm\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":304,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":565}'\u003eEnclosure size will increase for optional additions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":338,\"w\":565,\"h\":19,\"abs_x\":618,\"abs_y\":599}'\u003eProtection\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":371,\"w\":565,\"h\":117,\"abs_x\":618,\"abs_y\":632}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":371,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":632}'\u003eInner door mounted main isolator with door interlock\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":391,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":652}'\u003ePremium Schneider Circuit Breakers for individual pump protection\/isolation\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":410,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":671}'\u003eLow voltage control and input circuitry\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":430,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":691}'\u003ePremium Schneider Contactors for pump switching (three phase panels)\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":450,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":711}'\u003eElectronic short and overload protection of alarms\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":469,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":730}'\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":503,\"w\":565,\"h\":19,\"abs_x\":618,\"abs_y\":764}'\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":536,\"w\":565,\"h\":117,\"abs_x\":618,\"abs_y\":797}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":536,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":797}'\u003eHydroSTART dual pump capacitive touch keypad interface\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":556,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":817}'\u003eIndicator lights for system, pump and input status, level alarm\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":576,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":837}'\u003eButtons for alarm mute\/reset and pump mode selection\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":595,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":856}'\u003eHydroSTART PCB control module with dip-switches for adjusting configuration\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":615,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":876}'\u003eVisual (strobe) and audible (buzzer) alarms\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":634,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":895}'\u003ePump current sensing providing adjustable overload \u0026amp; other protections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":668,\"w\":565,\"h\":19,\"abs_x\":618,\"abs_y\":929}'\u003eInputs\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":702,\"w\":565,\"h\":97,\"abs_x\":618,\"abs_y\":963}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":702,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":963}'\u003ethree phase (400Vac) power supply\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":721,\"w\":525,\"h\":39,\"abs_x\":658,\"abs_y\":982}'\u003e6x digital inputs for float or pressure switches, optional prime loss flow switch and system enable\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":760,\"w\":525,\"h\":39,\"abs_x\":658,\"abs_y\":1021}'\u003eStandard terminal setup: Low level, duty stop, duty start, standby start, high level and system enable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":814,\"w\":565,\"h\":19,\"abs_x\":618,\"abs_y\":1075}'\u003eOutputs\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":847,\"w\":565,\"h\":58,\"abs_x\":618,\"abs_y\":1108}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":847,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":1108}'\u003e2x pump supply outputs\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":867,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":1128}'\u003eBMS volt free output for common fault\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":886,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":1147}'\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":920,\"w\":565,\"h\":19,\"abs_x\":618,\"abs_y\":1181}'\u003eFunctions\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":954,\"w\":565,\"h\":195,\"abs_x\":618,\"abs_y\":1215}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":954,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":1215}'\u003eLevel control mode – Level empty operation controlled by up to 5 float switches\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":973,\"w\":525,\"h\":39,\"abs_x\":658,\"abs_y\":1234}'\u003ePressure control mode – Pressure boost operation controlled by up to 3 pressure switches\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1012,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":1273}'\u003eDuty sharing and alternation – Alternates on pump start and after set run times\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1032,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":1293}'\u003eStaggered pump start – Prevents excessive current draw and reduces water surge\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1052,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":1313}'\u003eManual pump control – Manual mode with optional timeout\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1071,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":1332}'\u003eSystem enable input – Enables\/disables system in auto mode\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1091,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":1352}'\u003eStatic duty mode – No duty alternation\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1110,\"w\":525,\"h\":39,\"abs_x\":658,\"abs_y\":1371}'\u003eSmart chirp mode alarms – Audible alarm silences after 5 minutes, chirps every 5 minutes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":1163,\"w\":565,\"h\":19,\"abs_x\":618,\"abs_y\":1424}'\u003eFault Protection\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":1197,\"w\":565,\"h\":137,\"abs_x\":618,\"abs_y\":1458}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1197,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":1458}'\u003eHigh level alarm – Delayed alarm with auto\/manual reset depending on mode\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1217,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":1478}'\u003eLow level protection – Shuts down pumps, manual reset only\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1236,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":1497}'\u003eLow pressure protection – Shuts down pumps if input closed for 60 seconds\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1256,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":1517}'\u003ePrime loss protection – Shuts down pumps if no flow for 30 seconds\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1275,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":1536}'\u003ePump anti-seize protection – Runs pumps periodically during low use\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":1295,\"w\":525,\"h\":39,\"abs_x\":658,\"abs_y\":1556}'\u003ePump current sensing – Adjustable overload, undercurrent and zero current protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 bis_size='{\"x\":12,\"y\":1348,\"w\":565,\"h\":22,\"abs_x\":618,\"abs_y\":1609}'\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\" bis_size='{\"x\":12,\"y\":1382,\"w\":565,\"h\":55,\"abs_x\":618,\"abs_y\":1643}'\u003e\n\u003ctbody bis_size='{\"x\":15,\"y\":1385,\"w\":559,\"h\":49,\"abs_x\":621,\"abs_y\":1646}'\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":1385,\"w\":559,\"h\":23,\"abs_x\":621,\"abs_y\":1646}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":1385,\"w\":438,\"h\":23,\"abs_x\":621,\"abs_y\":1646}'\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":455,\"y\":1385,\"w\":119,\"h\":23,\"abs_x\":1061,\"abs_y\":1646}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/49bb51d56250b36b65102dad6bfc116f753bea7e.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":457,\"y\":1387,\"w\":63,\"h\":19,\"abs_x\":1063,\"abs_y\":1648}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":1410,\"w\":559,\"h\":23,\"abs_x\":621,\"abs_y\":1671}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":1410,\"w\":438,\"h\":23,\"abs_x\":621,\"abs_y\":1671}'\u003eAutomation and Control Product Guide\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":455,\"y\":1410,\"w\":119,\"h\":23,\"abs_x\":1061,\"abs_y\":1671}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/0fde2ce949a2d88c6cf6a1fee529c31b7451011f.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":457,\"y\":1412,\"w\":63,\"h\":19,\"abs_x\":1063,\"abs_y\":1673}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"Default Title","offer_id":45617222746221,"sku":"FPP-82243","price":4114.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPP-82243-PC-premium-polycarbonate-product.webp?v=1786603805"},{"product_id":"hydrostart-pro-submersible-pump-controller-3ph-2-pump-fpp-82243-pc","title":"HydroSTART PRO Submersible Pump Controller (3PH 2 Pump) - FPP-82243-PC","description":"\u003cp\u003eMATelec Australia’s HydroSTART PRO Controller is the flagship dual pump controller in the Australian Market. Designed for the professional, this controller features the highest quality enclosure, premium Schneider switchgear, intuitive capacitive touch keypad and Matelec Australia’s Market Leading HydroSTART Pro Control module.\u003c\/p\u003e\n\u003cp\u003eThe unit comes complete with pump current sensing and a wide range of electronic overload protection for both single and three phase pumps. A full suite of control inputs and functionality has been incorporated into the design to enhance the controller’s flexibility and cover an even wider range of pumping applications.\u003c\/p\u003e\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003ch4\u003eEnclosure Options\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003ePremium powder coated 316 stainless steel, IP66 with inner door\u003c\/li\u003e\n\u003cli\u003eEnclosure size: 400x400x200mm\u003c\/li\u003e\n\u003cli\u003eEnclosure size will increase for optional additions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProtection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eInner door mounted main isolator with door interlock\u003c\/li\u003e\n\u003cli\u003ePremium Schneider Circuit Breakers for individual pump protection\/isolation\u003c\/li\u003e\n\u003cli\u003eLow voltage control and input circuitry\u003c\/li\u003e\n\u003cli\u003ePremium Schneider Contactors for pump switching (three phase panels)\u003c\/li\u003e\n\u003cli\u003eElectronic short and overload protection of alarms\u003c\/li\u003e\n\u003cli\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHydroSTART dual pump capacitive touch keypad interface\u003c\/li\u003e\n\u003cli\u003eIndicator lights for system, pump and input status, level alarm\u003c\/li\u003e\n\u003cli\u003eButtons for alarm mute\/reset and pump mode selection\u003c\/li\u003e\n\u003cli\u003eHydroSTART PCB control module with dip-switches for adjusting configuration\u003c\/li\u003e\n\u003cli\u003eVisual (strobe) and audible (buzzer) alarms\u003c\/li\u003e\n\u003cli\u003ePump current sensing providing adjustable overload \u0026amp; other protections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003ethree phase (400Vac) power supply\u003c\/li\u003e\n\u003cli\u003e6x digital inputs for float or pressure switches, optional prime loss flow switch and system enable\u003c\/li\u003e\n\u003cli\u003eStandard terminal setup: Low level, duty stop, duty start, standby start, high level and system enable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOutputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e2x pump supply outputs\u003c\/li\u003e\n\u003cli\u003eBMS volt free output for common fault\u003c\/li\u003e\n\u003cli\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFunctions\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eLevel control mode – Level empty operation controlled by up to 5 float switches\u003c\/li\u003e\n\u003cli\u003ePressure control mode – Pressure boost operation controlled by up to 3 pressure switches\u003c\/li\u003e\n\u003cli\u003eDuty sharing and alternation – Alternates on pump start and after set run times\u003c\/li\u003e\n\u003cli\u003eStaggered pump start – Prevents excessive current draw and reduces water surge\u003c\/li\u003e\n\u003cli\u003eManual pump control – Manual mode with optional timeout\u003c\/li\u003e\n\u003cli\u003eSystem enable input – Enables\/disables system in auto mode\u003c\/li\u003e\n\u003cli\u003eStatic duty mode – No duty alternation\u003c\/li\u003e\n\u003cli\u003eSmart chirp mode alarms – Audible alarm silences after 5 minutes, chirps every 5 minutes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFault Protection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHigh level alarm – Delayed alarm with auto\/manual reset depending on mode\u003c\/li\u003e\n\u003cli\u003eLow level protection – Shuts down pumps, manual reset only\u003c\/li\u003e\n\u003cli\u003eLow pressure protection – Shuts down pumps if input closed for 60 seconds\u003c\/li\u003e\n\u003cli\u003ePrime loss protection – Shuts down pumps if no flow for 30 seconds\u003c\/li\u003e\n\u003cli\u003ePump anti-seize protection – Runs pumps periodically during low use\u003c\/li\u003e\n\u003cli\u003ePump current sensing – Adjustable overload, undercurrent and zero current protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/49bb51d56250b36b65102dad6bfc116f753bea7e.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomation and Control Product Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/0fde2ce949a2d88c6cf6a1fee529c31b7451011f.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"Default Title","offer_id":45617263444077,"sku":"FPP-82243-PC","price":5162.08,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPP-82243-PC-premium-polycarbonate-product.webp?v=1786603805"},{"product_id":"hydrostart-pro-submersible-pump-controller-3ph-2-pump-fpp-82243-ss","title":"HydroSTART PRO Submersible Pump Controller (3PH 2 Pump) - FPP-82243-SS","description":"\u003cp\u003eMATelec Australia’s HydroSTART PRO Controller is the flagship dual pump controller in the Australian Market. Designed for the professional, this controller features the highest quality enclosure, premium Schneider switchgear, intuitive capacitive touch keypad and Matelec Australia’s Market Leading HydroSTART Pro Control module.\u003c\/p\u003e\n\u003cp\u003eThe unit comes complete with pump current sensing and a wide range of electronic overload protection for both single and three phase pumps. A full suite of control inputs and functionality has been incorporated into the design to enhance the controller’s flexibility and cover an even wider range of pumping applications.\u003c\/p\u003e\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003ch4\u003eEnclosure Options\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003ePremium powder coated 316 stainless steel, IP66 with inner door\u003c\/li\u003e\n\u003cli\u003eEnclosure size: 400x400x200mm\u003c\/li\u003e\n\u003cli\u003eEnclosure size will increase for optional additions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProtection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eInner door mounted main isolator with door interlock\u003c\/li\u003e\n\u003cli\u003ePremium Schneider Circuit Breakers for individual pump protection\/isolation\u003c\/li\u003e\n\u003cli\u003eLow voltage control and input circuitry\u003c\/li\u003e\n\u003cli\u003ePremium Schneider Contactors for pump switching (three phase panels)\u003c\/li\u003e\n\u003cli\u003eElectronic short and overload protection of alarms\u003c\/li\u003e\n\u003cli\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHydroSTART dual pump capacitive touch keypad interface\u003c\/li\u003e\n\u003cli\u003eIndicator lights for system, pump and input status, level alarm\u003c\/li\u003e\n\u003cli\u003eButtons for alarm mute\/reset and pump mode selection\u003c\/li\u003e\n\u003cli\u003eHydroSTART PCB control module with dip-switches for adjusting configuration\u003c\/li\u003e\n\u003cli\u003eVisual (strobe) and audible (buzzer) alarms\u003c\/li\u003e\n\u003cli\u003ePump current sensing providing adjustable overload \u0026amp; other protections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003ethree phase (400Vac) power supply\u003c\/li\u003e\n\u003cli\u003e6x digital inputs for float or pressure switches, optional prime loss flow switch and system enable\u003c\/li\u003e\n\u003cli\u003eStandard terminal setup: Low level, duty stop, duty start, standby start, high level and system enable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOutputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e2x pump supply outputs\u003c\/li\u003e\n\u003cli\u003eBMS volt free output for common fault\u003c\/li\u003e\n\u003cli\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFunctions\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eLevel control mode – Level empty operation controlled by up to 5 float switches\u003c\/li\u003e\n\u003cli\u003ePressure control mode – Pressure boost operation controlled by up to 3 pressure switches\u003c\/li\u003e\n\u003cli\u003eDuty sharing and alternation – Alternates on pump start and after set run times\u003c\/li\u003e\n\u003cli\u003eStaggered pump start – Prevents excessive current draw and reduces water surge\u003c\/li\u003e\n\u003cli\u003eManual pump control – Manual mode with optional timeout\u003c\/li\u003e\n\u003cli\u003eSystem enable input – Enables\/disables system in auto mode\u003c\/li\u003e\n\u003cli\u003eStatic duty mode – No duty alternation\u003c\/li\u003e\n\u003cli\u003eSmart chirp mode alarms – Audible alarm silences after 5 minutes, chirps every 5 minutes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFault Protection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHigh level alarm – Delayed alarm with auto\/manual reset depending on mode\u003c\/li\u003e\n\u003cli\u003eLow level protection – Shuts down pumps, manual reset only\u003c\/li\u003e\n\u003cli\u003eLow pressure protection – Shuts down pumps if input closed for 60 seconds\u003c\/li\u003e\n\u003cli\u003ePrime loss protection – Shuts down pumps if no flow for 30 seconds\u003c\/li\u003e\n\u003cli\u003ePump anti-seize protection – Runs pumps periodically during low use\u003c\/li\u003e\n\u003cli\u003ePump current sensing – Adjustable overload, undercurrent and zero current protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/49bb51d56250b36b65102dad6bfc116f753bea7e.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomation and Control Product Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/0fde2ce949a2d88c6cf6a1fee529c31b7451011f.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"Default Title","offer_id":45617294147693,"sku":"FPP-82243-SS","price":5309.92,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPP-82243-SS-premium-polycarbonate-product.webp?v=1786604273"},{"product_id":"hydrostart-pro-submersible-pump-controller-3ph-2-pump-fpp-82243-x15","title":"HydroSTART PRO Submersible Pump Controller (3PH 2 Pump) - FPP-82243-X15","description":"\u003cp\u003eMATelec Australia’s HydroSTART PRO Controller is the flagship dual pump controller in the Australian Market. Designed for the professional, this controller features the highest quality enclosure, premium Schneider switchgear, intuitive capacitive touch keypad and Matelec Australia’s Market Leading HydroSTART Pro Control module.\u003c\/p\u003e\n\u003cp\u003eThe unit comes complete with pump current sensing and a wide range of electronic overload protection for both single and three phase pumps. A full suite of control inputs and functionality has been incorporated into the design to enhance the controller’s flexibility and cover an even wider range of pumping applications.\u003c\/p\u003e\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003ch4\u003eEnclosure Options\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eX15 orange powder coated galvanised mild steel, IP66 with inner door\u003c\/li\u003e\n\u003cli\u003eEnclosure size: 400x400x200mm\u003c\/li\u003e\n\u003cli\u003eEnclosure size will increase for optional additions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProtection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eInner door mounted main isolator with door interlock\u003c\/li\u003e\n\u003cli\u003ePremium Schneider Circuit Breakers for individual pump protection\/isolation\u003c\/li\u003e\n\u003cli\u003eLow voltage control and input circuitry\u003c\/li\u003e\n\u003cli\u003ePremium Schneider Contactors for pump switching (three phase panels)\u003c\/li\u003e\n\u003cli\u003eElectronic short and overload protection of alarms\u003c\/li\u003e\n\u003cli\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHydroSTART dual pump capacitive touch keypad interface\u003c\/li\u003e\n\u003cli\u003eIndicator lights for system, pump and input status, level alarm\u003c\/li\u003e\n\u003cli\u003eButtons for alarm mute\/reset and pump mode selection\u003c\/li\u003e\n\u003cli\u003eHydroSTART PCB control module with dip-switches for adjusting configuration\u003c\/li\u003e\n\u003cli\u003eVisual (strobe) and audible (buzzer) alarms\u003c\/li\u003e\n\u003cli\u003ePump current sensing providing adjustable overload \u0026amp; other protections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003ethree phase (400Vac) power supply\u003c\/li\u003e\n\u003cli\u003e6x digital inputs for float or pressure switches, optional prime loss flow switch and system enable\u003c\/li\u003e\n\u003cli\u003eStandard terminal setup: Low level, duty stop, duty start, standby start, high level and system enable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOutputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e2x pump supply outputs\u003c\/li\u003e\n\u003cli\u003eBMS volt free output for common fault\u003c\/li\u003e\n\u003cli\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFunctions\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eLevel control mode – Level empty operation controlled by up to 5 float switches\u003c\/li\u003e\n\u003cli\u003ePressure control mode – Pressure boost operation controlled by up to 3 pressure switches\u003c\/li\u003e\n\u003cli\u003eDuty sharing and alternation – Alternates on pump start and after set run times\u003c\/li\u003e\n\u003cli\u003eStaggered pump start – Prevents excessive current draw and reduces water surge\u003c\/li\u003e\n\u003cli\u003eManual pump control – Manual mode with optional timeout\u003c\/li\u003e\n\u003cli\u003eSystem enable input – Enables\/disables system in auto mode\u003c\/li\u003e\n\u003cli\u003eStatic duty mode – No duty alternation\u003c\/li\u003e\n\u003cli\u003eSmart chirp mode alarms – Audible alarm silences after 5 minutes, chirps every 5 minutes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFault Protection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHigh level alarm – Delayed alarm with auto\/manual reset depending on mode\u003c\/li\u003e\n\u003cli\u003eLow level protection – Shuts down pumps, manual reset only\u003c\/li\u003e\n\u003cli\u003eLow pressure protection – Shuts down pumps if input closed for 60 seconds\u003c\/li\u003e\n\u003cli\u003ePrime loss protection – Shuts down pumps if no flow for 30 seconds\u003c\/li\u003e\n\u003cli\u003ePump anti-seize protection – Runs pumps periodically during low use\u003c\/li\u003e\n\u003cli\u003ePump current sensing – Adjustable overload, undercurrent and zero current protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/49bb51d56250b36b65102dad6bfc116f753bea7e.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomation and Control Product Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/0fde2ce949a2d88c6cf6a1fee529c31b7451011f.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"Default Title","offer_id":45617355227245,"sku":"FPP-82243-X15","price":4413.2,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPP-82243-X15-product.webp?v=1786605791"},{"product_id":"hydrostart-submersible-level-controller-1ph-1-pump-0-1-16a-fpc-81141","title":"HydroSTART Submersible Level Controller (1PH 1 Pump 0.1-16A) - FPC-81141","description":"\u003cp\u003eThe HydroSTART Submersible Level Controller is designed for single pump applications, providing reliable level control, pump protection, and duty control. Featuring a capacitive touch interface, pump current sensing, and a range of electronic protection functions, the HydroSTART is suitable for a wide range of submersible pumping applications.\u003c\/p\u003e\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003ch4\u003eEnclosure\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003ePowder coated mild steel enclosure with removable gland plate\u003c\/li\u003e\n\u003cli\u003eIP54 rated with single door for indoor mounting\u003c\/li\u003e\n\u003cli\u003eEnclosure Size: 400×300×150 mm\u003c\/li\u003e\n\u003cli\u003eEnclosure size will increase for optional additions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProtection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSelectable overload range: 0.1-6 Amp, 5-16 Amp\u003c\/li\u003e\n\u003cli\u003ePad-lockable mains power isolator switch\u003c\/li\u003e\n\u003cli\u003eLow voltage control and input circuitry\u003c\/li\u003e\n\u003cli\u003eIndividual pump circuit breaker protection\/isolation\u003c\/li\u003e\n\u003cli\u003eElectronic short and overload protection\u003c\/li\u003e\n\u003cli\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHydroSTART single pump capacitive touch keypad interface\u003c\/li\u003e\n\u003cli\u003eIndicator lights for system and pump status\u003c\/li\u003e\n\u003cli\u003eButtons for alarm mute\/reset and pump mode selection\u003c\/li\u003e\n\u003cli\u003eHydroSTART PCB control module with dipswitches for adjusting configuration\u003c\/li\u003e\n\u003cli\u003eVisual (strobe) and audible (buzzer) alarms\u003c\/li\u003e\n\u003cli\u003ePump current sensing providing adjustable overload and other protections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSingle phase (230Vac) power supply\u003c\/li\u003e\n\u003cli\u003eUp to 6x digital inputs for float or pressure switches, optional prime loss flow switch and system enable\u003c\/li\u003e\n\u003cli\u003eStandard terminal setup: Low level, duty stop, duty start, standby start, high level and system enable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOutputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e1x pump supply output\u003c\/li\u003e\n\u003cli\u003eBMS volt-free output for common fault\u003c\/li\u003e\n\u003cli\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFunctions\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eLevel control mode for submersible pump applications\u003c\/li\u003e\n\u003cli\u003ePressure control mode for pressure boosting applications\u003c\/li\u003e\n\u003cli\u003eManual pump control\u003c\/li\u003e\n\u003cli\u003eSystem enable input\u003c\/li\u003e\n\u003cli\u003eStatic duty mode\u003c\/li\u003e\n\u003cli\u003eStaggered pump start\u003c\/li\u003e\n\u003cli\u003eSmart chirp mode alarms\u003c\/li\u003e\n\u003cli\u003ePump anti-seize protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFault Protection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHigh level alarm\u003c\/li\u003e\n\u003cli\u003eLow level protection\u003c\/li\u003e\n\u003cli\u003eLow pressure protection\u003c\/li\u003e\n\u003cli\u003ePrime loss protection\u003c\/li\u003e\n\u003cli\u003ePump current sensing with adjustable overload, undercurrent and zero current protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommon Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSewage pump out\u003c\/li\u003e\n\u003cli\u003eStormwater pump out\u003c\/li\u003e\n\u003cli\u003eWater transfer\u003c\/li\u003e\n\u003cli\u003ePressure boosting\u003c\/li\u003e\n\u003cli\u003eHot water recirculation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/08f5a11902b64509503920491cac62bb60c5a92e.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"0.1-6 Amp","offer_id":45716078887021,"sku":"FPC-81141\/0.1-6Amp","price":1594.56,"currency_code":"AUD","in_stock":true},{"title":"5-16 Amp","offer_id":45716078919789,"sku":"FPC-81141\/5-16Amp","price":1594.56,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/d0287a6b03a6c9a339d52cb12b7be4094117744f-1250x1250.webp?v=1786685602"},{"product_id":"hydrostart-submersible-level-controller-1ph-1-pump-12-18a-fpc-81141-e","title":"HydroSTART Submersible Level Controller (1PH 1 Pump 12-18A) - FPC-81141-E","description":"\u003cp\u003eThe HydroSTART Submersible Level Controller is designed for single pump applications, providing reliable level control, pump protection, and flexible control functionality. Featuring a capacitive touch interface, pump current sensing, and electronic protection, the HydroSTART is suitable for a wide range of submersible pumping applications.\u003c\/p\u003e\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003ch4\u003eEnclosure\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003ePowder coated mild steel enclosure with removable gland plate\u003c\/li\u003e\n\u003cli\u003eIP54 rated with single door for indoor mounting\u003c\/li\u003e\n\u003cli\u003eEnclosure size: 400×300×150 mm\u003c\/li\u003e\n\u003cli\u003eEnclosure size will increase for optional additions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProtection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e12-18 Amp thermal overload rating\u003c\/li\u003e\n\u003cli\u003ePad-lockable mains power isolator switch\u003c\/li\u003e\n\u003cli\u003eLow voltage control and input circuitry\u003c\/li\u003e\n\u003cli\u003eIndividual pump circuit breaker protection\/isolation\u003c\/li\u003e\n\u003cli\u003eElectronic short and overload protection\u003c\/li\u003e\n\u003cli\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHydroSTART single pump capacitive touch keypad interface\u003c\/li\u003e\n\u003cli\u003eIndicator lights for system and pump status\u003c\/li\u003e\n\u003cli\u003eButtons for alarm mute\/reset and pump mode selection\u003c\/li\u003e\n\u003cli\u003eHydroSTART PCB control module with dipswitches for adjusting configuration\u003c\/li\u003e\n\u003cli\u003eVisual (strobe) and audible (buzzer) alarms\u003c\/li\u003e\n\u003cli\u003ePump current sensing providing adjustable overload and other protections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSingle phase (230Vac) power supply\u003c\/li\u003e\n\u003cli\u003eUp to 6x digital inputs for float or pressure switches, optional prime loss flow switch and system enable\u003c\/li\u003e\n\u003cli\u003eStandard terminal setup: Low level, duty stop, duty start, standby start, high level and system enable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOutputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e1x pump supply output\u003c\/li\u003e\n\u003cli\u003eBMS volt-free output for common fault\u003c\/li\u003e\n\u003cli\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFunctions\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eLevel control mode for submersible pump applications\u003c\/li\u003e\n\u003cli\u003ePressure control mode for pressure boosting applications\u003c\/li\u003e\n\u003cli\u003eManual pump control\u003c\/li\u003e\n\u003cli\u003eSystem enable input\u003c\/li\u003e\n\u003cli\u003eStatic duty mode\u003c\/li\u003e\n\u003cli\u003eStaggered pump start\u003c\/li\u003e\n\u003cli\u003eSmart chirp mode alarms\u003c\/li\u003e\n\u003cli\u003ePump anti-seize protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFault Protection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHigh level alarm\u003c\/li\u003e\n\u003cli\u003eLow level protection\u003c\/li\u003e\n\u003cli\u003eLow pressure protection\u003c\/li\u003e\n\u003cli\u003ePrime loss protection\u003c\/li\u003e\n\u003cli\u003ePump current sensing with adjustable overload, undercurrent and zero current protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommon Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSewage pump out\u003c\/li\u003e\n\u003cli\u003eStormwater pump out\u003c\/li\u003e\n\u003cli\u003eWater transfer\u003c\/li\u003e\n\u003cli\u003ePressure boosting\u003c\/li\u003e\n\u003cli\u003eHot water recirculation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/08f5a11902b64509503920491cac62bb60c5a92e.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"Default Title","offer_id":45617399431277,"sku":"FPC-81141-E","price":1700.16,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/d0287a6b03a6c9a339d52cb12b7be4094117744f-1250x1250.webp?v=1786685602"},{"product_id":"hydrostart-submersible-level-controller-3ph-1-pump-0-1-16a-fpc-81143","title":"HydroSTART Submersible Level Controller (3PH 1 Pump 0.1-16A) - FPC-81143","description":"\u003cp\u003eThe HydroSTART Submersible Level Controller is designed for single pump applications, providing reliable level control, pump protection, and flexible control functionality. Featuring a capacitive touch interface, pump current sensing, and electronic protection, the HydroSTART is suitable for a wide range of submersible pumping applications.\u003c\/p\u003e\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003ch4\u003eEnclosure\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003ePowder coated mild steel enclosure with removable gland plate\u003c\/li\u003e\n\u003cli\u003eIP54 rated with single door for indoor mounting\u003c\/li\u003e\n\u003cli\u003eEnclosure size: 400×300×150 mm\u003c\/li\u003e\n\u003cli\u003eEnclosure size will increase for optional additions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProtection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSelectable overload range: 0.1-6 Amp, 5-16 Amp\u003c\/li\u003e\n\u003cli\u003ePad-lockable mains power isolator switch\u003c\/li\u003e\n\u003cli\u003eLow voltage control and input circuitry\u003c\/li\u003e\n\u003cli\u003eIndividual pump circuit breaker protection\/isolation\u003c\/li\u003e\n\u003cli\u003eContactors for pump switching\u003c\/li\u003e\n\u003cli\u003eElectronic short and overload protection\u003c\/li\u003e\n\u003cli\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHydroSTART single pump capacitive touch keypad interface\u003c\/li\u003e\n\u003cli\u003eIndicator lights for system and pump status\u003c\/li\u003e\n\u003cli\u003eButtons for alarm mute\/reset and pump mode selection\u003c\/li\u003e\n\u003cli\u003eHydroSTART PCB control module with dipswitches for adjusting configuration\u003c\/li\u003e\n\u003cli\u003eVisual (strobe) and audible (buzzer) alarms\u003c\/li\u003e\n\u003cli\u003ePump current sensing providing adjustable overload and other protections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThree phase (400Vac) power supply\u003c\/li\u003e\n\u003cli\u003eUp to 6x digital inputs for float or pressure switches, optional prime loss flow switch and system enable\u003c\/li\u003e\n\u003cli\u003eStandard terminal setup: Low level, duty stop, duty start, standby start, high level and system enable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOutputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e1x pump supply output\u003c\/li\u003e\n\u003cli\u003eBMS volt-free output for common fault\u003c\/li\u003e\n\u003cli\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFunctions\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eLevel control mode for submersible pump applications\u003c\/li\u003e\n\u003cli\u003ePressure control mode for pressure boosting applications\u003c\/li\u003e\n\u003cli\u003eManual pump control\u003c\/li\u003e\n\u003cli\u003eSystem enable input\u003c\/li\u003e\n\u003cli\u003eStatic duty mode\u003c\/li\u003e\n\u003cli\u003eStaggered pump start\u003c\/li\u003e\n\u003cli\u003eSmart chirp mode alarms\u003c\/li\u003e\n\u003cli\u003ePump anti-seize protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFault Protection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHigh level alarm\u003c\/li\u003e\n\u003cli\u003eLow level protection\u003c\/li\u003e\n\u003cli\u003eLow pressure protection\u003c\/li\u003e\n\u003cli\u003ePrime loss protection\u003c\/li\u003e\n\u003cli\u003ePump current sensing with adjustable overload, undercurrent and zero current protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommon Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSewage pump out\u003c\/li\u003e\n\u003cli\u003eStormwater pump out\u003c\/li\u003e\n\u003cli\u003eWater transfer\u003c\/li\u003e\n\u003cli\u003ePressure boosting\u003c\/li\u003e\n\u003cli\u003eHot water recirculation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/08f5a11902b64509503920491cac62bb60c5a92e.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"0.1-6 Amp","offer_id":45716079706221,"sku":"FPC-81143\/0.1-6Amp","price":1650.88,"currency_code":"AUD","in_stock":true},{"title":"5-16 Amp","offer_id":45716079738989,"sku":"FPC-81143\/5-16Amp","price":1650.88,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/d0287a6b03a6c9a339d52cb12b7be4094117744f-1250x1250.webp?v=1786685602"},{"product_id":"hydrostart-submersible-level-controller-3ph-1-pump-12-18a-fpc-81143-e","title":"HydroSTART Submersible Level Controller (3PH 1 Pump 12-18A) - FPC-81143-E","description":"\u003cp\u003eThe HydroSTART Submersible Level Controller is designed for single pump applications, providing reliable level control, pump protection, and flexible control functionality. Featuring a capacitive touch interface, pump current sensing, and electronic protection, the HydroSTART is suitable for a wide range of submersible pumping applications.\u003c\/p\u003e\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003ch4\u003eEnclosure\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003ePowder coated mild steel enclosure with removable gland plate\u003c\/li\u003e\n\u003cli\u003eIP54 rated with single door for indoor mounting\u003c\/li\u003e\n\u003cli\u003eEnclosure size: 400×300×150 mm\u003c\/li\u003e\n\u003cli\u003eEnclosure size will increase for optional additions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProtection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e12-18 Amp thermal overload rating\u003c\/li\u003e\n\u003cli\u003ePad-lockable mains power isolator switch\u003c\/li\u003e\n\u003cli\u003eLow voltage control and input circuitry\u003c\/li\u003e\n\u003cli\u003eIndividual pump circuit breaker protection\/isolation\u003c\/li\u003e\n\u003cli\u003eContactors for pump switching\u003c\/li\u003e\n\u003cli\u003eElectronic short and overload protection\u003c\/li\u003e\n\u003cli\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHydroSTART single pump capacitive touch keypad interface\u003c\/li\u003e\n\u003cli\u003eIndicator lights for system and pump status\u003c\/li\u003e\n\u003cli\u003eButtons for alarm mute\/reset and pump mode selection\u003c\/li\u003e\n\u003cli\u003eHydroSTART PCB control module with dipswitches for adjusting configuration\u003c\/li\u003e\n\u003cli\u003eVisual (strobe) and audible (buzzer) alarms\u003c\/li\u003e\n\u003cli\u003ePump current sensing providing adjustable overload and other protections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThree phase (400Vac) power supply\u003c\/li\u003e\n\u003cli\u003eUp to 6x digital inputs for float or pressure switches, optional prime loss flow switch and system enable\u003c\/li\u003e\n\u003cli\u003eStandard terminal setup: Low level, duty stop, duty start, standby start, high level and system enable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOutputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e1x pump supply output\u003c\/li\u003e\n\u003cli\u003eBMS volt-free output for common fault\u003c\/li\u003e\n\u003cli\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFunctions\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eLevel control mode for submersible pump applications\u003c\/li\u003e\n\u003cli\u003ePressure control mode for pressure boosting applications\u003c\/li\u003e\n\u003cli\u003eManual pump control\u003c\/li\u003e\n\u003cli\u003eSystem enable input\u003c\/li\u003e\n\u003cli\u003eStatic duty mode\u003c\/li\u003e\n\u003cli\u003eStaggered pump start\u003c\/li\u003e\n\u003cli\u003eSmart chirp mode alarms\u003c\/li\u003e\n\u003cli\u003ePump anti-seize protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFault Protection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHigh level alarm\u003c\/li\u003e\n\u003cli\u003eLow level protection\u003c\/li\u003e\n\u003cli\u003eLow pressure protection\u003c\/li\u003e\n\u003cli\u003ePrime loss protection\u003c\/li\u003e\n\u003cli\u003ePump current sensing with adjustable overload, undercurrent and zero current protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommon Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSewage pump out\u003c\/li\u003e\n\u003cli\u003eStormwater pump out\u003c\/li\u003e\n\u003cli\u003eWater transfer\u003c\/li\u003e\n\u003cli\u003ePressure boosting\u003c\/li\u003e\n\u003cli\u003eHot water recirculation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/08f5a11902b64509503920491cac62bb60c5a92e.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"Default Title","offer_id":45617400217709,"sku":"FPC-81143-E","price":1747.68,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/d0287a6b03a6c9a339d52cb12b7be4094117744f-1250x1250.webp?v=1786685602"},{"product_id":"hydrostart-submersible-level-controller-1ph-1-pump-0-1-16a-c-w-id-fpc-82141","title":"HydroSTART Submersible Level Controller (1PH 1 Pump 0.1-16A c\/w ID) - FPC-82141","description":"\u003cp\u003eThe HydroSTART Submersible Level Controller is designed for single pump applications, providing reliable level control, pump protection, and flexible control functionality. Featuring a capacitive touch interface, pump current sensing, and electronic protection, the HydroSTART is suitable for a wide range of submersible pumping applications.\u003c\/p\u003e\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003ch4\u003eEnclosure\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eEnclosure size: 400x300x200mm\u003c\/li\u003e\n\u003cli\u003ePowder coated mild steel enclosure with removable gland plate\u003c\/li\u003e\n\u003cli\u003eIP56 rated with inner door for outdoor mounting\u003c\/li\u003e\n\u003cli\u003eEnclosure size will increase for optional additions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProtection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSelectable overload range: 0.1-6 Amp, 5-16 Amp\u003c\/li\u003e\n\u003cli\u003ePad-lockable mains power isolator switch\u003c\/li\u003e\n\u003cli\u003eLow voltage control and input circuitry\u003c\/li\u003e\n\u003cli\u003eIndividual pump circuit breaker protection\/isolation\u003c\/li\u003e\n\u003cli\u003eElectronic short and overload protection\u003c\/li\u003e\n\u003cli\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHydroSTART single pump capacitive touch keypad interface\u003c\/li\u003e\n\u003cli\u003eIndicator lights for system and pump status\u003c\/li\u003e\n\u003cli\u003eButtons for alarm mute\/reset and pump mode selection\u003c\/li\u003e\n\u003cli\u003eHydroSTART PCB control module with dipswitches for adjusting configuration\u003c\/li\u003e\n\u003cli\u003eVisual (strobe) and audible (buzzer) alarms\u003c\/li\u003e\n\u003cli\u003ePump current sensing providing adjustable overload and other protections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSingle phase (230Vac) power supply\u003c\/li\u003e\n\u003cli\u003eUp to 6x digital inputs for float or pressure switches, optional prime loss flow switch and system enable\u003c\/li\u003e\n\u003cli\u003eStandard terminal setup: Low level, duty stop, duty start, standby start, high level and system enable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOutputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e1x pump supply output\u003c\/li\u003e\n\u003cli\u003eBMS volt-free output for common fault\u003c\/li\u003e\n\u003cli\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFunctions\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eLevel control mode for submersible pump applications\u003c\/li\u003e\n\u003cli\u003ePressure control mode for pressure boosting applications\u003c\/li\u003e\n\u003cli\u003eManual pump control\u003c\/li\u003e\n\u003cli\u003eSystem enable input\u003c\/li\u003e\n\u003cli\u003eStatic duty mode\u003c\/li\u003e\n\u003cli\u003eStaggered pump start\u003c\/li\u003e\n\u003cli\u003eSmart chirp mode alarms\u003c\/li\u003e\n\u003cli\u003ePump anti-seize protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFault Protection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHigh level alarm\u003c\/li\u003e\n\u003cli\u003eLow level protection\u003c\/li\u003e\n\u003cli\u003eLow pressure protection\u003c\/li\u003e\n\u003cli\u003ePrime loss protection\u003c\/li\u003e\n\u003cli\u003ePump current sensing with adjustable overload, undercurrent and zero current protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommon Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSewage pump out\u003c\/li\u003e\n\u003cli\u003eStormwater pump out\u003c\/li\u003e\n\u003cli\u003eWater transfer\u003c\/li\u003e\n\u003cli\u003ePressure boosting\u003c\/li\u003e\n\u003cli\u003eHot water recirculation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/08f5a11902b64509503920491cac62bb60c5a92e.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"0.1-6 Amp","offer_id":45716079902829,"sku":"FPC-82141\/5-16Amp","price":1609.52,"currency_code":"AUD","in_stock":true},{"title":"5-16 Amp","offer_id":45716079935597,"sku":"FPC-82141\/5-16Amp","price":1609.52,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/012394fd7b4aec162f3b73224f0a622368e8d98f-800x800.webp?v=1786685602"},{"product_id":"hydrostart-submersible-level-controller-1ph-1-pump-12-18a-c-w-id-fpc-82141-e","title":"HydroSTART Submersible Level Controller (1PH 1 Pump 12-18A c\/w ID) - FPC-82141-E","description":"\u003cp\u003eThe HydroSTART Submersible Level Controller is designed for single pump applications, providing reliable level control, pump protection, and flexible control functionality. Featuring a capacitive touch interface, pump current sensing, and electronic protection, the HydroSTART is suitable for a wide range of submersible pumping applications.\u003c\/p\u003e\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003ch4\u003eEnclosure\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eEnclosure size: 400x300x200mm\u003c\/li\u003e\n\u003cli\u003ePowder coated mild steel enclosure with removable gland plate\u003c\/li\u003e\n\u003cli\u003eIP56 rated with inner door for outdoor mounting\u003c\/li\u003e\n\u003cli\u003eEnclosure size will increase for optional additions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProtection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e12-18 Amp thermal overload rating\u003c\/li\u003e\n\u003cli\u003ePad-lockable mains power isolator switch\u003c\/li\u003e\n\u003cli\u003eLow voltage control and input circuitry\u003c\/li\u003e\n\u003cli\u003eIndividual pump circuit breaker protection\/isolation\u003c\/li\u003e\n\u003cli\u003eElectronic short and overload protection\u003c\/li\u003e\n\u003cli\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHydroSTART single pump capacitive touch keypad interface\u003c\/li\u003e\n\u003cli\u003eIndicator lights for system and pump status\u003c\/li\u003e\n\u003cli\u003eButtons for alarm mute\/reset and pump mode selection\u003c\/li\u003e\n\u003cli\u003eHydroSTART PCB control module with dipswitches for adjusting configuration\u003c\/li\u003e\n\u003cli\u003eVisual (strobe) and audible (buzzer) alarms\u003c\/li\u003e\n\u003cli\u003ePump current sensing providing adjustable overload and other protections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSingle phase (230Vac) power supply\u003c\/li\u003e\n\u003cli\u003eUp to 6x digital inputs for float or pressure switches, optional prime loss flow switch and system enable\u003c\/li\u003e\n\u003cli\u003eStandard terminal setup: Low level, duty stop, duty start, standby start, high level and system enable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOutputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e1x pump supply output\u003c\/li\u003e\n\u003cli\u003eBMS volt-free output for common fault\u003c\/li\u003e\n\u003cli\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFunctions\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eLevel control mode for submersible pump applications\u003c\/li\u003e\n\u003cli\u003ePressure control mode for pressure boosting applications\u003c\/li\u003e\n\u003cli\u003eManual pump control\u003c\/li\u003e\n\u003cli\u003eSystem enable input\u003c\/li\u003e\n\u003cli\u003eStatic duty mode\u003c\/li\u003e\n\u003cli\u003eStaggered pump start\u003c\/li\u003e\n\u003cli\u003eSmart chirp mode alarms\u003c\/li\u003e\n\u003cli\u003ePump anti-seize protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFault Protection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHigh level alarm\u003c\/li\u003e\n\u003cli\u003eLow level protection\u003c\/li\u003e\n\u003cli\u003eLow pressure protection\u003c\/li\u003e\n\u003cli\u003ePrime loss protection\u003c\/li\u003e\n\u003cli\u003ePump current sensing with adjustable overload, undercurrent and zero current protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommon Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSewage pump out\u003c\/li\u003e\n\u003cli\u003eStormwater pump out\u003c\/li\u003e\n\u003cli\u003eWater transfer\u003c\/li\u003e\n\u003cli\u003ePressure boosting\u003c\/li\u003e\n\u003cli\u003eHot water recirculation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/08f5a11902b64509503920491cac62bb60c5a92e.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"Default Title","offer_id":45617400643693,"sku":"FPC-82141-E","price":1716.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/012394fd7b4aec162f3b73224f0a622368e8d98f-800x800.webp?v=1786685602"},{"product_id":"hydrostart-submersible-level-controller-3ph-1-pump-0-1-16a-c-w-id-fpc-82143","title":"HydroSTART Submersible Level Controller (3PH 1 Pump 0.1-16A c\/w ID) - FPC-82143","description":"\u003cp\u003eThe HydroSTART Submersible Level Controller is designed for single pump applications, providing reliable level control, pump protection, and flexible control functionality. Featuring a capacitive touch interface, pump current sensing, and electronic protection, the HydroSTART is suitable for a wide range of submersible pumping applications.\u003c\/p\u003e\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003ch4\u003eEnclosure\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eEnclosure size: 400x400x200mm\u003c\/li\u003e\n\u003cli\u003ePowder coated mild steel enclosure with removable gland plate\u003c\/li\u003e\n\u003cli\u003eIP56 rated with inner door for outdoor mounting\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eEnclosure size will increase for optional additions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProtection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSelectable overload range: 0.1-6 Amp, 5-16 Amp\u003c\/li\u003e\n\u003cli\u003ePad-lockable mains power isolator switch\u003c\/li\u003e\n\u003cli\u003eLow voltage control and input circuitry\u003c\/li\u003e\n\u003cli\u003eIndividual pump circuit breaker protection\/isolation\u003c\/li\u003e\n\u003cli\u003eContactors for pump switching\u003c\/li\u003e\n\u003cli\u003eElectronic short and overload protection\u003c\/li\u003e\n\u003cli\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHydroSTART single pump capacitive touch keypad interface\u003c\/li\u003e\n\u003cli\u003eIndicator lights for system and pump status\u003c\/li\u003e\n\u003cli\u003eButtons for alarm mute\/reset and pump mode selection\u003c\/li\u003e\n\u003cli\u003eHydroSTART PCB control module with dipswitches for adjusting configuration\u003c\/li\u003e\n\u003cli\u003eVisual (strobe) and audible (buzzer) alarms\u003c\/li\u003e\n\u003cli\u003ePump current sensing providing adjustable overload and other protections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThree phase (400Vac) power supply\u003c\/li\u003e\n\u003cli\u003eUp to 6x digital inputs for float or pressure switches, optional prime loss flow switch and system enable\u003c\/li\u003e\n\u003cli\u003eStandard terminal setup: Low level, duty stop, duty start, standby start, high level and system enable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOutputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e1x pump supply output\u003c\/li\u003e\n\u003cli\u003eBMS volt-free output for common fault\u003c\/li\u003e\n\u003cli\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFunctions\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eLevel control mode for submersible pump applications\u003c\/li\u003e\n\u003cli\u003ePressure control mode for pressure boosting applications\u003c\/li\u003e\n\u003cli\u003eManual pump control\u003c\/li\u003e\n\u003cli\u003eSystem enable input\u003c\/li\u003e\n\u003cli\u003eStatic duty mode\u003c\/li\u003e\n\u003cli\u003eStaggered pump start\u003c\/li\u003e\n\u003cli\u003eSmart chirp mode alarms\u003c\/li\u003e\n\u003cli\u003ePump anti-seize protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFault Protection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHigh level alarm\u003c\/li\u003e\n\u003cli\u003eLow level protection\u003c\/li\u003e\n\u003cli\u003eLow pressure protection\u003c\/li\u003e\n\u003cli\u003ePrime loss protection\u003c\/li\u003e\n\u003cli\u003ePump current sensing with adjustable overload, undercurrent and zero current protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommon Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSewage pump out\u003c\/li\u003e\n\u003cli\u003eStormwater pump out\u003c\/li\u003e\n\u003cli\u003eWater transfer\u003c\/li\u003e\n\u003cli\u003ePressure boosting\u003c\/li\u003e\n\u003cli\u003eHot water recirculation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/08f5a11902b64509503920491cac62bb60c5a92e.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"0.1-6 Amp","offer_id":45716080361581,"sku":"FPC-82143\/0.1-6Amp","price":1665.84,"currency_code":"AUD","in_stock":true},{"title":"5-16 Amp","offer_id":45716080394349,"sku":"FPC-82143\/5-16Amp","price":1665.84,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/012394fd7b4aec162f3b73224f0a622368e8d98f-800x800.webp?v=1786685602"},{"product_id":"hydrostart-submersible-level-controller-3ph-1-pump-12-18a-c-w-id-fpc-82143-e","title":"HydroSTART Submersible Level Controller (3PH 1 Pump 12-18A c\/w ID) - FPC-82143-E","description":"\u003cp\u003eThe HydroSTART Submersible Level Controller is designed for single pump applications, providing reliable level control, pump protection, and flexible control functionality. Featuring a capacitive touch interface, pump current sensing, and electronic protection, the HydroSTART is suitable for a wide range of submersible pumping applications.\u003c\/p\u003e\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003ch4\u003eEnclosure\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eEnclosure size: 400x400x200mm\u003c\/li\u003e\n\u003cli\u003ePowder coated mild steel enclosure with removable gland plate\u003c\/li\u003e\n\u003cli\u003eIP56 rated with inner door for outdoor mounting\u003c\/li\u003e\n\u003cli\u003eEnclosure size will increase for optional additions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProtection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e12-18 Amp thermal overload rating\u003c\/li\u003e\n\u003cli\u003ePad-lockable mains power isolator switch\u003c\/li\u003e\n\u003cli\u003eLow voltage control and input circuitry\u003c\/li\u003e\n\u003cli\u003eIndividual pump circuit breaker protection\/isolation\u003c\/li\u003e\n\u003cli\u003eContactors for pump switching\u003c\/li\u003e\n\u003cli\u003eElectronic short and overload protection\u003c\/li\u003e\n\u003cli\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHydroSTART single pump capacitive touch keypad interface\u003c\/li\u003e\n\u003cli\u003eIndicator lights for system and pump status\u003c\/li\u003e\n\u003cli\u003eButtons for alarm mute\/reset and pump mode selection\u003c\/li\u003e\n\u003cli\u003eHydroSTART PCB control module with dipswitches for adjusting configuration\u003c\/li\u003e\n\u003cli\u003eVisual (strobe) and audible (buzzer) alarms\u003c\/li\u003e\n\u003cli\u003ePump current sensing providing adjustable overload and other protections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThree phase (400Vac) power supply\u003c\/li\u003e\n\u003cli\u003eUp to 6x digital inputs for float or pressure switches, optional prime loss flow switch and system enable\u003c\/li\u003e\n\u003cli\u003eStandard terminal setup: Low level, duty stop, duty start, standby start, high level and system enable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOutputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e1x pump supply output\u003c\/li\u003e\n\u003cli\u003eBMS volt-free output for common fault\u003c\/li\u003e\n\u003cli\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFunctions\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eLevel control mode for submersible pump applications\u003c\/li\u003e\n\u003cli\u003ePressure control mode for pressure boosting applications\u003c\/li\u003e\n\u003cli\u003eManual pump control\u003c\/li\u003e\n\u003cli\u003eSystem enable input\u003c\/li\u003e\n\u003cli\u003eStatic duty mode\u003c\/li\u003e\n\u003cli\u003eStaggered pump start\u003c\/li\u003e\n\u003cli\u003eSmart chirp mode alarms\u003c\/li\u003e\n\u003cli\u003ePump anti-seize protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFault Protection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHigh level alarm\u003c\/li\u003e\n\u003cli\u003eLow level protection\u003c\/li\u003e\n\u003cli\u003eLow pressure protection\u003c\/li\u003e\n\u003cli\u003ePrime loss protection\u003c\/li\u003e\n\u003cli\u003ePump current sensing with adjustable overload, undercurrent and zero current protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommon Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSewage pump out\u003c\/li\u003e\n\u003cli\u003eStormwater pump out\u003c\/li\u003e\n\u003cli\u003eWater transfer\u003c\/li\u003e\n\u003cli\u003ePressure boosting\u003c\/li\u003e\n\u003cli\u003eHot water recirculation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/08f5a11902b64509503920491cac62bb60c5a92e.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"Default Title","offer_id":45617402937453,"sku":"FPC-82143-E","price":1764.4,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/012394fd7b4aec162f3b73224f0a622368e8d98f-800x800.webp?v=1786685602"},{"product_id":"hydrostart-stainless-steel-1ph-1-pump-0-1-16a-c-w-id-316ss-enclosure-fpc-82141-ss","title":"HydroSTART Stainless Steel (1PH 1 Pump 0.1-16A c\/w ID, 316SS Enclosure) - FPC-82141-SS","description":"\u003cp bis_size='{\"x\":12,\"y\":9,\"w\":565,\"h\":78,\"abs_x\":618,\"abs_y\":270}'\u003eThe HydroSTART Stainless Steel Controller is a single-pump controller for 1-phase \/ 230Vac applications, supplied with an IP56 inner-door enclosure constructed from 316 stainless steel. It provides electronic pump protection, level monitoring, duty control and alarm functionality.\u003c\/p\u003e\n\u003ch3 bis_size='{\"x\":12,\"y\":103,\"w\":565,\"h\":22,\"abs_x\":618,\"abs_y\":364}'\u003eProduct Details\u003c\/h3\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":137,\"w\":565,\"h\":19,\"abs_x\":618,\"abs_y\":398}'\u003eEnclosure\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":171,\"w\":565,\"h\":78,\"abs_x\":618,\"abs_y\":432}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":171,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":432}'\u003e316 stainless steel enclosure\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":190,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":451}'\u003eIP56 rated with inner door for outdoor mounting\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":210,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":471}'\u003eEnclosure size: 400x300x200mm\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":229,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":490}'\u003eEnclosure size will increase for optional additions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":263,\"w\":565,\"h\":19,\"abs_x\":618,\"abs_y\":524}'\u003eProtection\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":297,\"w\":565,\"h\":97,\"abs_x\":618,\"abs_y\":558}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":297,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":558}'\u003ePad-lockable mains power isolator switch\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":316,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":577}'\u003eLow voltage control and input circuitry\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":336,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":597}'\u003eIndividual pump circuit breaker protection\/isolation\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":355,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":616}'\u003eElectronic short and overload protection\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":375,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":636}'\u003eDIN rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":408,\"w\":565,\"h\":19,\"abs_x\":618,\"abs_y\":669}'\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":442,\"w\":565,\"h\":117,\"abs_x\":618,\"abs_y\":703}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":442,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":703}'\u003eHydroSTART single-pump capacitive touch keypad interface\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":462,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":723}'\u003eIndicator lights for system, pump and input status, and level alarm\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":481,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":742}'\u003eButtons for alarm mute\/reset and pump mode selection\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":501,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":762}'\u003eHydroSTART PCB control module with DIP switches for configuration\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":520,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":781}'\u003eVisual (strobe) and audible (buzzer) alarms\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":540,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":801}'\u003ePump current sensing providing adjustable overload and other protections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":574,\"w\":565,\"h\":19,\"abs_x\":618,\"abs_y\":835}'\u003eInputs\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":607,\"w\":565,\"h\":97,\"abs_x\":618,\"abs_y\":868}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":607,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":868}'\u003eSingle phase (230Vac) power supply\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":627,\"w\":525,\"h\":39,\"abs_x\":658,\"abs_y\":888}'\u003e6x digital inputs for float or pressure switches, optional prime loss flow switch and system enable\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":666,\"w\":525,\"h\":39,\"abs_x\":658,\"abs_y\":927}'\u003eStandard terminal setup: Low level, duty stop, duty start, standby start, high level and system enable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":719,\"w\":565,\"h\":19,\"abs_x\":618,\"abs_y\":980}'\u003eOutputs\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":753,\"w\":565,\"h\":58,\"abs_x\":618,\"abs_y\":1014}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":753,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":1014}'\u003e1x pump supply output\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":772,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":1033}'\u003eBMS volt-free output for common fault\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":792,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":1053}'\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 bis_size='{\"x\":12,\"y\":826,\"w\":565,\"h\":22,\"abs_x\":618,\"abs_y\":1087}'\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\" bis_size='{\"x\":12,\"y\":859,\"w\":565,\"h\":106,\"abs_x\":618,\"abs_y\":1120}'\u003e\n\u003ctbody bis_size='{\"x\":15,\"y\":862,\"w\":559,\"h\":100,\"abs_x\":621,\"abs_y\":1123}'\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":862,\"w\":559,\"h\":23,\"abs_x\":621,\"abs_y\":1123}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":862,\"w\":438,\"h\":23,\"abs_x\":621,\"abs_y\":1123}'\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":455,\"y\":862,\"w\":119,\"h\":23,\"abs_x\":1061,\"abs_y\":1123}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/0fde2ce949a2d88c6cf6a1fee529c31b7451011f.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":457,\"y\":864,\"w\":63,\"h\":19,\"abs_x\":1063,\"abs_y\":1125}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":888,\"w\":559,\"h\":23,\"abs_x\":621,\"abs_y\":1149}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":888,\"w\":438,\"h\":23,\"abs_x\":621,\"abs_y\":1149}'\u003eAutomation and Control Product Guide\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":455,\"y\":888,\"w\":119,\"h\":23,\"abs_x\":1061,\"abs_y\":1149}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/08f5a11902b64509503920491cac62bb60c5a92e.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":457,\"y\":890,\"w\":63,\"h\":19,\"abs_x\":1063,\"abs_y\":1151}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":913,\"w\":559,\"h\":23,\"abs_x\":621,\"abs_y\":1174}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":913,\"w\":438,\"h\":23,\"abs_x\":621,\"abs_y\":1174}'\u003eInstruction Manual\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":455,\"y\":913,\"w\":119,\"h\":23,\"abs_x\":1061,\"abs_y\":1174}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/2bd7c38a494e8c01cbfb4d1f1189308a61b1a103.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":457,\"y\":915,\"w\":63,\"h\":19,\"abs_x\":1063,\"abs_y\":1176}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":939,\"w\":559,\"h\":23,\"abs_x\":621,\"abs_y\":1200}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":939,\"w\":438,\"h\":23,\"abs_x\":621,\"abs_y\":1200}'\u003eQuick Start Guide\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":455,\"y\":939,\"w\":119,\"h\":23,\"abs_x\":1061,\"abs_y\":1200}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/85a2dcb6f7983bd6b95a1a57c28f6e6839cb322b.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":457,\"y\":941,\"w\":63,\"h\":19,\"abs_x\":1063,\"abs_y\":1202}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"Default Title","offer_id":45617464737901,"sku":"FPC-82141-SS","price":3743.52,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPC-82141-SS-product-with-control-module.webp?v=1786609417"},{"product_id":"hydrostart-stainless-steel-3ph-1-pump-0-1-16a-c-w-id-316ss-enclosure-fpc-82143-ss","title":"HydroSTART Stainless Steel (3PH 1 Pump 0.1-16A c\/w ID, 316SS Enclosure) - FPC-82143-SS","description":"\u003cp bis_size='{\"x\":12,\"y\":9,\"w\":565,\"h\":78,\"abs_x\":618,\"abs_y\":270}'\u003eThe HydroSTART Stainless Steel Controller is a single-pump controller for 3-phase \/ 400Vac applications, supplied with an IP56 inner-door enclosure constructed from 316 stainless steel. It provides electronic pump protection, level monitoring, duty control and alarm functionality.\u003c\/p\u003e\n\u003ch3 bis_size='{\"x\":12,\"y\":103,\"w\":565,\"h\":22,\"abs_x\":618,\"abs_y\":364}'\u003eProduct Details\u003c\/h3\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":137,\"w\":565,\"h\":19,\"abs_x\":618,\"abs_y\":398}'\u003eEnclosure\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":171,\"w\":565,\"h\":78,\"abs_x\":618,\"abs_y\":432}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":171,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":432}'\u003e316 stainless steel enclosure\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":190,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":451}'\u003eIP56 rated with inner door for outdoor mounting\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":210,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":471}'\u003eEnclosure size: 400x400x200mm\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":229,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":490}'\u003eEnclosure size will increase for optional additions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":263,\"w\":565,\"h\":19,\"abs_x\":618,\"abs_y\":524}'\u003eProtection\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":297,\"w\":565,\"h\":97,\"abs_x\":618,\"abs_y\":558}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":297,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":558}'\u003ePad-lockable mains power isolator switch\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":316,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":577}'\u003eLow voltage control and input circuitry\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":336,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":597}'\u003eIndividual pump circuit breaker protection\/isolation\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":355,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":616}'\u003eElectronic short and overload protection\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":375,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":636}'\u003eDIN rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":408,\"w\":565,\"h\":19,\"abs_x\":618,\"abs_y\":669}'\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":442,\"w\":565,\"h\":117,\"abs_x\":618,\"abs_y\":703}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":442,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":703}'\u003eHydroSTART single-pump capacitive touch keypad interface\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":462,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":723}'\u003eIndicator lights for system, pump and input status, and level alarm\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":481,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":742}'\u003eButtons for alarm mute\/reset and pump mode selection\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":501,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":762}'\u003eHydroSTART PCB control module with DIP switches for configuration\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":520,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":781}'\u003eVisual (strobe) and audible (buzzer) alarms\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":540,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":801}'\u003ePump current sensing providing adjustable overload and other protections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":574,\"w\":565,\"h\":19,\"abs_x\":618,\"abs_y\":835}'\u003eInputs\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":607,\"w\":565,\"h\":97,\"abs_x\":618,\"abs_y\":868}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":607,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":868}'\u003eThree phase (400Vac) power supply\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":627,\"w\":525,\"h\":39,\"abs_x\":658,\"abs_y\":888}'\u003e6x digital inputs for float or pressure switches, optional prime loss flow switch and system enable\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":666,\"w\":525,\"h\":39,\"abs_x\":658,\"abs_y\":927}'\u003eStandard terminal setup: Low level, duty stop, duty start, standby start, high level and system enable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 bis_size='{\"x\":12,\"y\":719,\"w\":565,\"h\":19,\"abs_x\":618,\"abs_y\":980}'\u003eOutputs\u003c\/h4\u003e\n\u003cul bis_size='{\"x\":12,\"y\":753,\"w\":565,\"h\":58,\"abs_x\":618,\"abs_y\":1014}'\u003e\n\u003cli bis_size='{\"x\":52,\"y\":753,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":1014}'\u003e1x pump supply output\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":772,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":1033}'\u003eBMS volt-free output for common fault\u003c\/li\u003e\n\u003cli bis_size='{\"x\":52,\"y\":792,\"w\":525,\"h\":19,\"abs_x\":658,\"abs_y\":1053}'\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 bis_size='{\"x\":12,\"y\":826,\"w\":565,\"h\":22,\"abs_x\":618,\"abs_y\":1087}'\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\" bis_size='{\"x\":12,\"y\":859,\"w\":565,\"h\":106,\"abs_x\":618,\"abs_y\":1120}'\u003e\n\u003ctbody bis_size='{\"x\":15,\"y\":862,\"w\":559,\"h\":100,\"abs_x\":621,\"abs_y\":1123}'\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":862,\"w\":559,\"h\":23,\"abs_x\":621,\"abs_y\":1123}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":862,\"w\":438,\"h\":23,\"abs_x\":621,\"abs_y\":1123}'\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":455,\"y\":862,\"w\":119,\"h\":23,\"abs_x\":1061,\"abs_y\":1123}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/0fde2ce949a2d88c6cf6a1fee529c31b7451011f.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":457,\"y\":864,\"w\":63,\"h\":19,\"abs_x\":1063,\"abs_y\":1125}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":888,\"w\":559,\"h\":23,\"abs_x\":621,\"abs_y\":1149}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":888,\"w\":438,\"h\":23,\"abs_x\":621,\"abs_y\":1149}'\u003eAutomation and Control Product Guide\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":455,\"y\":888,\"w\":119,\"h\":23,\"abs_x\":1061,\"abs_y\":1149}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/08f5a11902b64509503920491cac62bb60c5a92e.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":457,\"y\":890,\"w\":63,\"h\":19,\"abs_x\":1063,\"abs_y\":1151}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":913,\"w\":559,\"h\":23,\"abs_x\":621,\"abs_y\":1174}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":913,\"w\":438,\"h\":23,\"abs_x\":621,\"abs_y\":1174}'\u003eInstruction Manual\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":455,\"y\":913,\"w\":119,\"h\":23,\"abs_x\":1061,\"abs_y\":1174}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/2bd7c38a494e8c01cbfb4d1f1189308a61b1a103.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":457,\"y\":915,\"w\":63,\"h\":19,\"abs_x\":1063,\"abs_y\":1176}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bis_size='{\"x\":15,\"y\":939,\"w\":559,\"h\":23,\"abs_x\":621,\"abs_y\":1200}'\u003e\n\u003ctd bis_size='{\"x\":15,\"y\":939,\"w\":438,\"h\":23,\"abs_x\":621,\"abs_y\":1200}'\u003eQuick Start Guide\u003c\/td\u003e\n\u003ctd bis_size='{\"x\":455,\"y\":939,\"w\":119,\"h\":23,\"abs_x\":1061,\"abs_y\":1200}'\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/85a2dcb6f7983bd6b95a1a57c28f6e6839cb322b.pdf\" rel=\"noopener noreferrer\" bis_size='{\"x\":457,\"y\":941,\"w\":63,\"h\":19,\"abs_x\":1063,\"abs_y\":1202}' target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"Default Title","offer_id":45617466966125,"sku":"FPC-82143-SS","price":4051.52,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPC-82143-SS-product-with-control-module.webp?v=1786609548"},{"product_id":"hydrostart-stainless-steel-1ph-2-pump-0-1-16a-c-w-id-316ss-enclosure-fpc-82241-ss","title":"HydroSTART Stainless Steel (1PH 2 Pump 0.1-16A c\/w ID \u0026 316SS Enclosure) - FPC-82241-SS","description":"\u003cp\u003eMATelec Australia’s HydroSTART Controller provides reliable control for dual pump applications, featuring a capacitive touch keypad, pump current sensing, electronic overload protection, and a premium 316 stainless steel enclosure. The HydroSTART is designed to provide flexible pump control across a wide range of pumping applications.\u003c\/p\u003e\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003ch4\u003eEnclosure\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e316 stainless steel enclosure\u003c\/li\u003e\n\u003cli\u003eIP56 rated with inner door for outdoor mounting\u003c\/li\u003e\n\u003cli\u003eEnclosure size: 400x400x200mm\u003c\/li\u003e\n\u003cli\u003eEnclosure size will increase for optional additions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProtection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003ePad-lockable mains power isolator switch\u003c\/li\u003e\n\u003cli\u003eLow voltage control and input circuitry\u003c\/li\u003e\n\u003cli\u003eIndividual pump circuit breaker protection\/isolation\u003c\/li\u003e\n\u003cli\u003eElectronic short and overload protection of alarms\u003c\/li\u003e\n\u003cli\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHydroSTART dual pump capacitive touch keypad interface\u003c\/li\u003e\n\u003cli\u003eIndicator lights for system, pump and input status and level alarm\u003c\/li\u003e\n\u003cli\u003eButtons for alarm mute\/reset and pump mode selection\u003c\/li\u003e\n\u003cli\u003eHydroSTART PCB control module with dipswitches for adjusting configuration\u003c\/li\u003e\n\u003cli\u003eVisual (strobe) and audible (buzzer) alarms\u003c\/li\u003e\n\u003cli\u003ePump current sensing providing adjustable overload and other protections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSingle phase (230Vac) power supply\u003c\/li\u003e\n\u003cli\u003eUp to 6 digital inputs for float or pressure switches, optional prime loss flow switch and system enable\u003c\/li\u003e\n\u003cli\u003eStandard terminal setup: Low level, duty stop, duty start, standby start, high level and system enable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOutputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e2x pump supply outputs\u003c\/li\u003e\n\u003cli\u003eBMS volt-free output for common fault\u003c\/li\u003e\n\u003cli\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/08f5a11902b64509503920491cac62bb60c5a92e.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomation and Control Product Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/0fde2ce949a2d88c6cf6a1fee529c31b7451011f.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstruction Manual\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/2bd7c38a494e8c01cbfb4d1f1189308a61b1a103.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuick Start Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/85a2dcb6f7983bd6b95a1a57c28f6e6839cb322b.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"Default Title","offer_id":45617467752557,"sku":"FPC-82241-SS","price":3428.48,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPC-82241-SS-product-with-control-module.webp?v=1786609864"},{"product_id":"hydrostart-stainless-steel-3ph-2-pump-0-1-16a-c-w-id-316ss-enclosure-fpc-82243-ss","title":"HydroSTART Stainless Steel (3PH 2 Pump 0.1-16A c\/w ID \u0026 316SS Enclosure) - FPC-82243-SS","description":"\u003cp\u003eMATelec Australia’s HydroSTART Controller provides reliable control for dual pump applications, featuring a capacitive touch keypad, pump current sensing, electronic overload protection, and a premium 316 stainless steel enclosure. The HydroSTART is designed to provide flexible pump control across a wide range of pumping applications.\u003c\/p\u003e\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003ch4\u003eEnclosure\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e316 stainless steel enclosure\u003c\/li\u003e\n\u003cli\u003eIP56 rated with inner door for outdoor mounting\u003c\/li\u003e\n\u003cli\u003eEnclosure size: 400x400x200mm\u003c\/li\u003e\n\u003cli\u003eEnclosure size will increase for optional additions\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProtection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003ePad-lockable mains power isolator switch\u003c\/li\u003e\n\u003cli\u003eLow voltage control and input circuitry\u003c\/li\u003e\n\u003cli\u003eIndividual pump circuit breaker protection\/isolation\u003c\/li\u003e\n\u003cli\u003eContactors for pump switching (three-phase panels)\u003c\/li\u003e\n\u003cli\u003eElectronic short and overload protection of alarms\u003c\/li\u003e\n\u003cli\u003eDin rail mounted terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControl \u0026amp; Interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHydroSTART dual pump capacitive touch keypad interface\u003c\/li\u003e\n\u003cli\u003eIndicator lights for system, pump and input status and level alarm\u003c\/li\u003e\n\u003cli\u003eButtons for alarm mute\/reset and pump mode selection\u003c\/li\u003e\n\u003cli\u003eHydroSTART PCB control module with dipswitches for adjusting configuration\u003c\/li\u003e\n\u003cli\u003eVisual (strobe) and audible (buzzer) alarms\u003c\/li\u003e\n\u003cli\u003ePump current sensing providing adjustable overload and other protections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThree phase (400Vac) power supply\u003c\/li\u003e\n\u003cli\u003eUp to 6 digital inputs for float or pressure switches, optional prime loss flow switch and system enable\u003c\/li\u003e\n\u003cli\u003eStandard terminal setup: Low level, duty stop, duty start, standby start, high level and system enable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOutputs\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e2x pump supply outputs\u003c\/li\u003e\n\u003cli\u003eBMS volt-free output for common fault\u003c\/li\u003e\n\u003cli\u003eModbus RTU Serial RS485 connections for SCADA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocumentation \u0026amp; Downloads\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Spec Sheet\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/08f5a11902b64509503920491cac62bb60c5a92e.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomation and Control Product Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/0fde2ce949a2d88c6cf6a1fee529c31b7451011f.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstruction Manual\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/2bd7c38a494e8c01cbfb4d1f1189308a61b1a103.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuick Start Guide\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.sanity.io\/files\/1uk9rgzk\/production\/85a2dcb6f7983bd6b95a1a57c28f6e6839cb322b.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Matelec","offers":[{"title":"Default Title","offer_id":45617470373997,"sku":"FPC-82243-SS","price":3716.24,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1399\/2979\/files\/FPC-82243-SS-product-with-control-module.webp?v=1786609963"}],"url":"https:\/\/pumptastic.com.au\/collections\/advanced-pump-controllers.oembed","provider":"Pumptastic","version":"1.0","type":"link"}